Scope

JJF 1923-2021 is the English-translated version of 电测量仪表校验装置校准规范.

JJF 1923-2021 is the Chinese standard "Calibration Specification for Verification Equipment of Electrical Measuring Devices". Issued on 2021-10-18, in force from 2022-04-18.

Found what you need?

Document preview — JJF 1923-2021

Contents

  • 1 Scope(1)
  • 2 References (1)
  • 3 Overview(1)
  • 4 Metrology Characteristics(1)
  • 4.1 Accuracy class(1)
  • 4.2 Short-term stability(2)
  • 4.3 Load Regulation(2)
  • 4.4 Waveform Distortion(2)
  • 4.5 Symmetry(2)
  • 4.6 DC ripple(2)
  • 5 Calibration Conditions(2)
  • 5.1 Environmental conditions (2)
  • 5.2 Measurement standards and other equipment(2)
  • 6 Calibration items and calibration methods (2)
  • 6.1 Calibration items (2)
  • 6.2 Calibration method(3)
  • 7 Expression of calibration results (13)
  • 8 Recalibration interval(13)
  • Introduction

1 Scope(1)

2 References (1)

3 Overview(1)

4 Metrology Characteristics(1)

4.1 Accuracy class(1)

4.2 Short-term stability(2)

4.3 Load Regulation(2)

4.4 Waveform Distortion(2)

4.5 Symmetry(2)

4.6 DC ripple(2)

5 Calibration Conditions(2)

5.1 Environmental conditions (2)

5.2 Measurement standards and other equipment(2)

6 Calibration items and calibration methods (2)

6.1 Calibration items (2)

6.2 Calibration method(3)

7 Expression of calibration results (13)

8 Recalibration interval(13)

Appendix A Example of AC Voltage Calibration Uncertainty Evaluation(14)

Appendix B Calibration Raw Record Format(17)

Appendix C Calibration Certificate Inside Page Format (24)

Introduction

This specification is based on JJF 1071-2010 "Rules for Compilation of National Metrology Calibration Specifications", JJF 1059.1-2012 "Measurement Uncertainty Evaluation and Representation" was compiled.

This specification is published for the first time.

Calibration specification for calibration devices for electrical measuring instruments

1 Scope

This specification applies to the calibration of the calibration device for electrical measuring instruments of class 0.05 and below (hereinafter referred to as the calibration device).

The calibration device has single-phase or three-phase AC voltage, current, frequency, power and phase output functions, and can have direct Current voltage, DC current output function.

In this specification, the upper limit of AC voltage is 1000V, the upper limit of AC current is 100A, and the frequency range is 40Hz~ 70Hz; the upper limit of DC voltage is 1000V, and the upper limit of DC current is 100A.

2 Reference documents this specification references the following documents.

GB/T 15637-2012 General Specification for Digital Multimeter Calibrator for dated references, only the dated version applies to this specification; for undated references the latest version (including all amendments) applies to this specification.

3 Overview

The calibration device is composed of a signal output unit, a standard measurement unit and a control display unit, etc. It is generally used for calibration/Calibrate single-phase or three-phase voltmeter, ammeter, power meter and other AC and DC measuring instruments, its structure can be divided into meter source There are two types. integrated type and table source separated type.

4 Metrology characteristics

4.1 Accuracy class

The accuracy level and maximum allowable error of the calibration device are shown in Table 1.

Table 1 Accuracy class and maximum allowable error of calibration device

Features

maximum allowable error Level 0.05 Level 0.1 Level 0.2 AC voltage, current ±0.05% ±0.1% ±0.2% Active power ±0.05% ±0.1% ±0.2% Reactive power ±0.1% ±0.2% ±0.5% Phase/(°) ±0.1 ±0.2 ±0.5 Frequency/Hz ±0.01 ±0.02 ±0.05 DC voltage, current ±0.05% ±0.1% ±0.2% Note. The maximum allowable error of other functions except phase and frequency refers to the guide error, which is expressed as a percentage.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 23 pages — is available in the English PDF.

How to Download JJF 1923-2021

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Fast delivery

    After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
23 pages
Fast delivery
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

JJF 1923-2021

$480.00