JJF 1918-2021 is the English-translated version of 电容式加速度传感器校准规范.
JJF 1918-2021 is the Chinese standard "Calibration Specification for Capacitive Acceleration Sensor". Issued on 2021-07-28, in force from 2022-01-28.
Found what you need?
Document preview — JJF 1918-2021
Contents
- 1 Scope(1)
- 2 References (1)
- 3 Overview(1)
- 4 Metrology Characteristics(1)
- 4.1 Static characteristics(1)
- 4.2 Dynamic Characteristics(1)
- 5 Calibration Conditions(2)
- 5.1 Environmental conditions (2)
- 5.2 Measurement standards and other equipment(2)
- 6 Calibration items and calibration methods (2)
- 6.1 Calibration items (2)
- 6.2 Calibration method(2)
- 7 Expression of calibration results (7)
- 7.1 Calibration records (7)
- 7.2 Calibration certificate(7)
- 8 Recalibration interval(7)
- Introduction
1 Scope(1)
2 References (1)
3 Overview(1)
4 Metrology Characteristics(1)
4.1 Static characteristics(1)
4.2 Dynamic Characteristics(1)
5 Calibration Conditions(2)
5.1 Environmental conditions (2)
5.2 Measurement standards and other equipment(2)
6 Calibration items and calibration methods (2)
6.1 Calibration items (2)
6.2 Calibration method(2)
7 Expression of calibration results (7)
7.1 Calibration records (7)
7.2 Calibration certificate(7)
8 Recalibration interval(7)
Appendix A Determination of Local Gravitational Acceleration (8)
Appendix B Recommended Format for Calibration Raw Records(9)
Appendix C Calibration Certificate Contents and Inner Page Format (11)
Appendix D Example of Static Sensitivity Measurement Uncertainty Evaluation of Capacitive Accelerometers(13)
Introduction
This specification is prepared in accordance with JJF 1071-2010 "Rules for Compilation of National Metrology and Calibration Specifications". JJF 1071 "Country Rules for Writing Metrological Calibration Specifications, JJF 1001 "General Metrology Terms and Definitions" and JJF 1059.1 "Inaccurate Measurements" "Sentimental Evaluation and Representation" together constitute the basic series of specifications supporting the formulation of this specification.
This specification is published for the first time.
Calibration Specification for Capacitive Accelerometers
1 Scope
This specification applies to the calibration of capacitive acceleration sensors (hereinafter referred to as accelerometers).
2 Reference documents this specification references the following documents.
JJG2054-2015 Vibration measuring instrument verification system table JJF 1156-2006 Terms and Definitions of Vibration Shock Speed Measurement GB/T 20485.11-2006 Vibration and shock sensor calibration method Part 11: Laser interferometry vibration Dynamic absolute calibration GB/T 20485.16-2018 Vibration and shock sensor calibration method Part 16: Earth gravity method calibration GB/T 20485.21-2007 Vibration and shock sensor calibration method Part 21: Vibration comparison method calibration IEC 60747-14-4:2011 Semiconductor devices Discrete devices Part 14-4.Semiconductor inductors (Semi-for dated references, only the dated version applies to this specification; for undated references the latest version (including all amendments) applies to this specification.
3 Overview
Capacitive accelerometers are widely used for vibration and shock measurements.
The structure of capacitive acceleration sensor generally adopts a spring mass system, which consists of a fixed mass block and a sensitive mass block.
to form a plate capacitor. The mass block is moved by the inertial force to change the capacitance value of the plate. By detecting large changes in capacitance Small, measure the magnitude and direction of the sensitive axis acceleration.
4 Metrology characteristics
4.1 Static characteristics Static sensitivity.
4.2 Dynamic Characteristics
a) reference sensitivity;
b) Sensitivity frequency response;
c) Sensitivity amplitude linearity.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 13 pages — is available in the English PDF.
How to Download JJF 1918-2021
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Fast delivery
After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
JJF 2425-2026 — Calibration specification for carbon dioxide incubators
JJF 1183-2025 — Calibration Specification for Temperature Transmitters
JJF 1282-2025 — Calibration Specification for Time Delay Relays
JJF 1918-2021
$210.00