JJF 1917-2021Microscopic ruler calibration specification (English PDF)
显微标尺校准规范
This is a limited preview
Buy now to download the full PDF (10 pages)
Need quotation for your management?
Get a formal quotation for JJF 1917-2021 in 30 minutes.
Issued by
State Administration for Market Regulation
Level / Type
National · Mandatory
Issue date
July 28, 2021
Implementation date
January 28, 2022
Scope
JJF 1917-2021 is the English-translated version of 显微标尺校准规范.
JJF 1917-2021 is the Chinese standard "Microscopic ruler calibration specification". Issued on 2021-07-28, in force from 2022-01-28.
Found what you need?
Document preview — JJF 1917-2021
Contents
- 1 Scope(1)
- 2 Overview(1)
- 3 Metrology Characteristics(2)
- 3.1 Line spacing (2)
- 3.2 Grid spacing(2)
- 3.3 Angle(2)
- 3.4 Diameter(2)
- 4 Calibration Conditions(2)
- 4.1 Environmental conditions (2)
- 4.2 Standard device for calibration (3)
- 5 Calibration items and calibration methods (3)
- 5.1 General rules for calibration (3)
- 5.2 Line spacing (3)
- 5.3 Grid spacing(4)
- 5.4 Angle(4)
- 5.5 Diameter(4)
- 6 Processing of calibration results (4)
- 7 Recalibration interval(5)
- Introduction
1 Scope(1)
2 Overview(1)
3 Metrology Characteristics(2)
3.1 Line spacing (2)
3.2 Grid spacing(2)
3.3 Angle(2)
3.4 Diameter(2)
4 Calibration Conditions(2)
4.1 Environmental conditions (2)
4.2 Standard device for calibration (3)
5 Calibration items and calibration methods (3)
5.1 General rules for calibration (3)
5.2 Line spacing (3)
5.3 Grid spacing(4)
5.4 Angle(4)
5.5 Diameter(4)
6 Processing of calibration results (4)
7 Recalibration interval(5)
Appendix A Example of Measurement Uncertainty Evaluation of Micro-Scale Line Pitch (1) (6)
Appendix B Example of Measurement Uncertainty Evaluation of Micro-Scale Line Pitch (2) (8)
Appendix C Standard Certificate Content (10)
Introduction
JJF 1071 "Rules for the Compilation of National Metrology Calibration Specifications", JJF 1001 "General Metrology Terms and Definitions" and JJF 1059.1 "Assessment and Representation of Measurement Uncertainty" together constitute the basic series supporting the formulation of this specification.
The purpose of formulating this specification is mainly to solve GB/T 2985-2008 "Biological Microscope", JB/T 10077-1999 "Metallographic Microscope" in line grain ruler and JJG571-2004 "Reading and measuring microscope", JJF 1402-2013 "Biological Microscope Calibration Specification", JJF 1914-2021 "Metallographic Microscope Calibration Specification" in line standard calibration.
The line rulers, line standards, etc. in the above standards, regulations and calibration specifications are collectively referred to as microscopic standards in this specification.
Ruler, classified in JJF 1022-2014 "Measuring Standard Nomenclature and Classification Code" "Microscopic Ruler Standard Device" (code.
01213300).
This specification is published for the first time.
Microscale Calibration Specifications
1 Scope
This specification applies to the calibration of one-dimensional or two-dimensional microscopic rulers with a reticle width of 0.3 µm and above.
2 Overview
Micro rulers are used to calibrate optical microscopes such as biological microscopes, metallographic microscopes, reading microscopes and their accessories.
A set of one-dimensional or two-dimensional standard instruments for technical parameters such as software indication and magnification, also refers to such instruments used to observe and measure microscopic Image of eyepiece ruler. Microscopic rulers contain one or more geometric patterns such as dots, lines, circles, rectangles, crosses, etc.
Contains information such as width, spacing, diameter, area, and angle. Microscopic rulers are usually made of transparent glass or metal Substrate; according to the manufacturing method, it is divided into groove, photocopying and etching process manufacturing; according to the pattern presentation method, it is divided into transparent According to the application, it is divided into stage micrometer, eyepiece micrometer, etc.
Stage micrometers are glass slides that contain various geometric patterns. The usual stage micrometer has a long center (1~2)mm micrometer, reticle interval (100~600) lines/mm. Indication error for calibrating microscopes, Resolution, magnification, eyepiece reticle accuracy and microscopic measurement software accuracy.
The eyepiece micrometer is a circular glass slide with central lines, crosses, grids, circles, etc., which is installed in the microscope eyepiece.
The imaging surface of the object is used to measure or calibrate the size of the microscopic image.
The geometric pattern of a typical microscale is shown in Figure 1.
(a) Combined micrometer
Figure 1 Schematic diagram of the microscopic ruler
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 10 pages — is available in the English PDF.
How to Download JJF 1917-2021
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Fast delivery
After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
JJF 2425-2026 — Calibration specification for carbon dioxide incubators
JJF 1183-2025 — Calibration Specification for Temperature Transmitters
JJF 1282-2025 — Calibration Specification for Time Delay Relays
JJF 1917-2021