Valid

JJF 1916-2021Scanning Electron Microscope Calibration Specification (English PDF)

扫描电子显微镜校准规范

Preview PDF

This is a limited preview

Buy now to download the full PDF (9 pages)

Need quotation for your management?

Get a formal quotation for JJF 1916-2021 in 30 minutes.

Issued by

State Administration for Market Regulation

Level / Type

National · Mandatory

Issue date

July 28, 2021

Implementation date

January 28, 2022

Scope

JJF 1916-2021 is the English-translated version of 扫描电子显微镜校准规范.

JJF 1916-2021 is the Chinese standard "Scanning Electron Microscope Calibration Specification". Issued on 2021-07-28, in force from 2022-01-28.

Found what you need?

Document preview — JJF 1916-2021

Contents

  • 1 Scope(1)
  • 2 References (1)
  • 3 Terms and Definitions(1)
  • 3.1 Standard template(1)
  • 4 Overview(1)
  • 5 Metrology Characteristics(1)
  • 6 Calibration Conditions(2)
  • 6.1 Environmental conditions (2)
  • 6.2 Standard for calibration (2)
  • 7 Calibration items and calibration methods (2)
  • 7.1 Length measurement and indication error (2)
  • 7.2 Orthogonal Distortion(3)
  • 7.3 Linear Distortion(3)
  • 8 Expression of calibration results (4)
  • 9 Recalibration interval(4)
  • Introduction

1 Scope(1)

2 References (1)

3 Terms and Definitions(1)

3.1 Standard template(1)

4 Overview(1)

5 Metrology Characteristics(1)

6 Calibration Conditions(2)

6.1 Environmental conditions (2)

6.2 Standard for calibration (2)

7 Calibration items and calibration methods (2)

7.1 Length measurement and indication error (2)

7.2 Orthogonal Distortion(3)

7.3 Linear Distortion(3)

8 Expression of calibration results (4)

9 Recalibration interval(4)

Appendix A Example of Uncertainty Evaluation of Length Measurement and Indication Error of Scanning Electron Microscope (5)

Appendix B Scale Calibration Values(7)

Appendix C Calibration Certificate Contents and Inner Page Format (8)

Introduction

JJF 1071 "Rules for the Compilation of National Metrology Calibration Specifications", JJF 1001 "General Metrology Terms and Definitions" and JJF 1059.1 "Assessment and Representation of Measurement Uncertainty" together constitute the basic series supporting the formulation and revision of this specification.

This specification is the revision of JJG550-1988 "Scanning Electron Microscope (Trial)". Reference during revision GB/T 20307-2006 "General Principles of Scanning Electron Microscope Measurement Methods of Nanometer Length" and GB/T 27788-2011 "Guidelines for Microbeam Analysis Scanning Electron Microscope Image Magnification Calibration". Compared with JJG550-1988, except for editorial revisions the main technical changes are as follows.

--- Increase the calibration of the error of the scanning electron microscope length measurement indication value;

---Increased the calibration of the length measurement and indication error in the Y direction;

--- Deleted the measurement of vacuum degree;

--- Deleted the measurement of X-ray leakage;

--- Added Appendix B "Scale Calibration Values".

The previous releases of this specification are as follows.

---JJG550-1988.

Scanning Electron Microscope Calibration Specification

1 Scope

This specification applies to the calibration of scanning electron microscopes.

2 Reference documents this specification references the following documents.

JJF 1071-2010 Rules for Compilation of National Metrology and Calibration Specifications GB/T 20307-2006 General rules for measuring method of scanning electron microscope of nanometer length for dated references, only the dated version applies to this specification; for undated references the latest version (including all amendments) applies to this specification.

3 Terms and Definitions the following terms and definitions apply to this specification.

3.1 Standard template referenceartifact A template with multiple equally spaced grids, the grid spacing is calibrated by the national legal metrology verification agency, and the spacing value is Traceable to national benchmarks.

4 Overview

Scanning electron microscope (hereinafter referred to as "electron microscope") uses a focused electron beam to scan point by point on the surface of the sample.

The interaction between the electron and the sample generates secondary electron signals and backscattered electron signals, thereby obtaining surface topography images, which can reach resolution to the nanometer level. Its structure is shown in Figure 1.

Fig.1 Schematic diagram of scanning electron microscope structure

1- electron gun; 2- focusing lens; 3- scanning coil; 4- signal detector; 5- sample; 6- sample chamber; 7- vacuum system

5 Metrology characteristics the measurement characteristics of the electron microscope are shown in Table 1, and the performance indicators are for reference during calibration.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 9 pages — is available in the English PDF.

How to Download JJF 1916-2021

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Fast delivery

    After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
9 pages
Fast delivery
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

JJF 1916-2021

$210.00