Scope
JJF 1914-2021 (Calibration Specification for Metallographic Microscope) is available as an English-translated PDF.
JJF 1914-2021 is the Chinese standard "Calibration Specification for Metallographic Microscope". Issued on 2021-07-28, in force from 2022-01-28.
Found what you need?
Document preview — JJF 1914-2021
Contents
- 1 Scope(1)
- 2 References (1)
- 3 Overview(1)
- 4 Metrology Characteristics(1)
- 4.1 Relative deviation of left and right field of view center of binocular microscope (1)
- 4.2 Objective lens magnification error (1)
- 4.3 Indication error(1)
- 5 Calibration Conditions(1)
- 5.1 Environmental conditions (1)
- 5.2 Calibration standard (2)
- 6 Calibration items and calibration methods (2)
- 6.1 Relative deviation of left and right field of view center of binocular microscope (2)
- 6.2 Objective lens magnification error(2)
- 6.3 Indication error(3)
- 7 Expression of calibration results (3)
- 8 Recalibration interval(3)
- Introduction
1 Scope(1)
2 References (1)
3 Overview(1)
4 Metrology Characteristics(1)
4.1 Relative deviation of left and right field of view center of binocular microscope (1)
4.2 Objective lens magnification error (1)
4.3 Indication error(1)
5 Calibration Conditions(1)
5.1 Environmental conditions (1)
5.2 Calibration standard (2)
6 Calibration items and calibration methods (2)
6.1 Relative deviation of left and right field of view center of binocular microscope (2)
6.2 Objective lens magnification error(2)
6.3 Indication error(3)
7 Expression of calibration results (3)
8 Recalibration interval(3)
Appendix A Example of Calibration Uncertainty Evaluation of Indication Error (4)
Introduction
JJF 1071-2010 "Rules for the Compilation of National Metrology Calibration Standards", JJF 1001-2011 "General Metrology Terms and Definition" and JJF 1059.1-2012 "Measurement Uncertainty Evaluation and Representation" together constitute support for the formulation of this specification the basic series of specifications.
In the formulation process of this specification, reference is made to GB/T 22059-2018 "Microscope Magnification Values, Tolerances and Symbols" no." and JB/T 10077-1999 "Metallographic Microscope".
This specification is published for the first time.
Calibration Specifications for Metallographic Microscopes
1 Scope
This specification applies to monocular, binocular observation type and metallographic microscopes with image sensor receiving type.
calibration.
2 Reference documents this specification references the following documents.
JJF 1071-2010 Rules for Compilation of National Metrology and Calibration Specifications JB/T 10077-1999 Metallographic microscope for dated references, only the dated version applies to this specification; for undated references the latest version (including all amendments) applies to this specification.
3 Overview
A metallographic microscope is an optical instrument used to observe and measure the microstructure of metals. According to metallographic microscope the method of observing the image of the object can be divided into the eyepiece observation type and the image sensor receiving type metallographic microscope.
4 Metrology characteristics
4.1 Relative deviation of left and right field of view center of binocular microscope Up and down. not more than 0.2mm;
Left and right. the outer side is not more than 0.2mm; the inner side is not more than 0.4mm.
4.2 Objective lens magnification error the maximum allowable error of the magnification of the objective lens is generally not more than ±5%.
4.3 Indication error Indication error generally does not exceed the provisions of Table 1.
Table 1 Indication error
Objective lens magnification Gamma<=10× 10×50× Indication error ±(0.01mm 5×10-2L) ±(0.003mm 5×10-2L)±(0.002mm 5×10-2L) Note. L---Measurement length.
Note. The calibration work does not judge whether it is qualified or not, and the above measurement characteristics requirements are for reference only.
5 Calibration Conditions
5.1 Environmental conditions
5.1.1 The indoor temperature for calibrating the metallographic microscope should be within the range of (20±5)°C.
5.1.2 The calibration room should be free from dust, vibration and corrosive gases that may affect calibration.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 7 pages — is available in the English PDF.
Referenced standards
How to Download JJF 1914-2021
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
JJF 2425-2026 — Calibration specification for carbon dioxide incubators
JJF 1183-2025 — Calibration Specification for Temperature Transmitters
JJF 1282-2025 — Calibration Specification for Time Delay Relays
Secure payment via Stripe
Payments accepted
JJF 1914-2021
$75.00