JJF 1913-2021Calibration specification for laser interferometer (English PDF)
激光干涉比长仪校准规范
This is a limited preview
Buy now to download the full PDF (9 pages)
Need quotation for your management?
Get a formal quotation for JJF 1913-2021 in 30 minutes.
Issued by
State Administration for Market Regulation
Level / Type
National · Mandatory
Issue date
July 28, 2021
Implementation date
January 28, 2022
Scope
JJF 1913-2021 is the English-translated version of 激光干涉比长仪校准规范.
JJF 1913-2021 is the Chinese standard "Calibration specification for laser interferometer". Issued on 2021-07-28, in force from 2022-01-28.
Found what you need?
Document preview — JJF 1913-2021
Contents
- 1 Scope(1)
- 2 References (1)
- 3 Terms and Definitions(1)
- 4 Overview(1)
- 5 Metrology Characteristics(2)
- 5.1 Straightness of table movement (2)
- 5.2 Aiming repeatability(2)
- 5.3 Measurement repeatability(2)
- 5.4 Indication error of image probe (2)
- 5.5 Indication error(2)
- 6 Calibration Conditions(2)
- 6.1 General calibration conditions(2)
- 6.2 Environmental conditions (2)
- 6.3 Standard for calibration (2)
- 7 Calibration items and calibration methods (3)
- 7.1 Straightness of table movement (3)
- 7.2 Aiming repeatability(3)
- 7.3 Measurement repeatability(4)
- 7.4 Indication error of image probe (4)
- 7.5 Indication error(5)
- 8 Expression of calibration results (5)
- 9 Recalibration interval(5)
- Introduction
1 Scope(1)
2 References (1)
3 Terms and Definitions(1)
4 Overview(1)
5 Metrology Characteristics(2)
5.1 Straightness of table movement (2)
5.2 Aiming repeatability(2)
5.3 Measurement repeatability(2)
5.4 Indication error of image probe (2)
5.5 Indication error(2)
6 Calibration Conditions(2)
6.1 General calibration conditions(2)
6.2 Environmental conditions (2)
6.3 Standard for calibration (2)
7 Calibration items and calibration methods (3)
7.1 Straightness of table movement (3)
7.2 Aiming repeatability(3)
7.3 Measurement repeatability(4)
7.4 Indication error of image probe (4)
7.5 Indication error(5)
8 Expression of calibration results (5)
9 Recalibration interval(5)
Appendix A Example of Measurement Uncertainty Evaluation of Indication Error of Laser Interferometer (6)
Appendix B Calibration Certificate Contents and Inner Page Format (8)
Introduction
JJF 1071 "Rules for the Compilation of National Metrology Calibration Specifications", JJF 1001 "General Metrology Terms and Definitions" and JJF 1059.1 "Assessment and Representation of Measurement Uncertainty" together constitute the basic series supporting the formulation of this specification.
This specification replaces JJG331-1994 "Laser Interferometer". Compared with JJG331-1994, except for editorial in addition to the modification, the main technical changes are as follows.
--- Replace the accuracy of the ratiometer with the indication error of the laser interference ratiometer;
--- Modified the measurement repeatability calibration and its data processing method;
--- Increased aiming repeatability and its calibration method;
--- Delete the uniformity of the laser parallel beam, the contrast of the interference fringes and the quality of the output signal, the measurement light Verification items such as the consistency of beam and movement direction, and the uniformity of table movement speed;
--- Added related calibration items for the image probe aiming system;
--- Added the measurement uncertainty evaluation example of the indication error of the laser interferometer in Appendix A.
The previous releases of this specification are as follows.
---JJG331-1994.
---JJG331-1983.
Laser Interferometer Calibration Specification
1 Scope
This specification applies to the calibration of laser interferometers with a measurement range of (0~1000) mm.
2 Reference documents this specification references the following documents.
JJG73-2005 High-grade line ruler JJF 1001-2011 General Metrology Terms and Definitions JJF 1059.1 Evaluation and representation of measurement uncertainty JJF 1094-2002 Characteristic Evaluation of Measuring Instruments for dated references, only the dated version applies to this specification; for undated references the latest version (including all amendments) applies to this specification.
3 Terms and Definitions the following terms and definitions apply to this specification.
The minimum scribe line interval of the line ruler that can be effectively measured by the laser interferometry.
4 Overview
The laser interferometer is based on the laser wavelength as the length measurement benchmark, and directly measures the linear ruler, linear displacement sensor, laser Optical interferometer is a standard instrument for measuring the length of the line value class. The laser interferometer consists of a mechanical main body, a length measuring system, a aiming system, motion control system, lighting system, environmental parameter measurement system and data processing system, etc.
The structure is shown in Figure 1.The length measuring system includes frequency-stabilized laser light source, interference optical path, wavelength correction system, etc.; aiming system Use a photoelectric microscope or an image probe for reticle aiming or reading.
Figure 1 Laser Interferometer
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 9 pages — is available in the English PDF.
How to Download JJF 1913-2021
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Fast delivery
After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
JJF 2425-2026 — Calibration specification for carbon dioxide incubators
JJF 1183-2025 — Calibration Specification for Temperature Transmitters
JJF 1282-2025 — Calibration Specification for Time Delay Relays
JJF 1913-2021
$150.00