JJF 1910-2021Calibration specification for electrochemical workstation (English PDF)
电化学工作站校准规范
This is a limited preview
Buy now to download the full PDF (12 pages)
Need quotation for your management?
Get a formal quotation for JJF 1910-2021 in 30 minutes.
Issued by
State Administration for Market Regulation
Level / Type
National · Mandatory
Issue date
July 28, 2021
Implementation date
January 28, 2022
Scope
JJF 1910-2021 is the English-translated version of 电化学工作站校准规范.
JJF 1910-2021 is the Chinese standard "Calibration specification for electrochemical workstation". Issued on 2021-07-28, in force from 2022-01-28.
Found what you need?
Document preview — JJF 1910-2021
Contents
- 1 Scope(1)
- 2 References (1)
- 3 Terms (1)
- 3.1 Working electrode(1)
- 3.2 Reference electrode(1)
- 3.3 Auxiliary electrode(1)
- 4 Overview(1)
- 5 Metrology Characteristics(1)
- 6 Calibration Conditions(2)
- 6.1 Environmental conditions (2)
- 6.2 Instruments and reagents for calibration (2)
- 7 Calibration items and calibration methods (2)
- 7.1 Potential indication error (2)
- 7.2 Current indication error(3)
- 7.3 Spike repeatability(3)
- 8 Expression of calibration results (4)
- 9 Recalibration interval(4)
- Introduction
1 Scope(1)
2 References (1)
3 Terms (1)
3.1 Working electrode(1)
3.2 Reference electrode(1)
3.3 Auxiliary electrode(1)
4 Overview(1)
5 Metrology Characteristics(1)
6 Calibration Conditions(2)
6.1 Environmental conditions (2)
6.2 Instruments and reagents for calibration (2)
7 Calibration items and calibration methods (2)
7.1 Potential indication error (2)
7.2 Current indication error(3)
7.3 Spike repeatability(3)
8 Expression of calibration results (4)
9 Recalibration interval(4)
Appendix A Glassy Carbon Electrode Pretreatment Method (5)
Appendix B Preparation Method of Electrochemical Workstation Calibration Solution(6)
Appendix C Calibration Record Reference Format(7)
Appendix D Example of Uncertainty Evaluation of Indication Error Measurement Results (9)
APPENDIX E RECOMMENDED FORM OF INNER PAGE OF CALIBRATION CERTIFICATE(12)
Introduction
JJF 1071 "Rules for the Compilation of National Metrology Calibration Specifications", JJF 1001 "General Metrology Terms and Definitions" and JJF 1059.1 "Assessment and Representation of Measurement Uncertainty" together constitute the basic series of regulations supporting the formulation of this specification.
Fan. This specification is compiled with reference to YY/T 1074-2002 "Pitting Corrosion Potential of Stainless Steel Products for Surgical Implants".
This specification is published for the first time.
Electrochemical Workstation Calibration Specifications
1 Scope
This specification applies to the analysis of the electrochemical properties of substances, equipped with a three-electrode system, with potentiostatic and cyclic voltammetry calibration of the electrochemical workstation.
2 Reference documents this specification references the following documents.
JJF 1059.1-2012 Evaluation and representation of measurement uncertainty YY/T 1074-2002 Pitting corrosion potential of stainless steel products for surgical implants for dated references, only the dated version applies to this specification; for undated references files, the latest version of which applies to this specification.
3 Terminology
3.1 Working electrode Electrodes to be studied and measured in electrochemical systems.
3.2 Reference electrode an electrode with a stable repetitive potential value can use its potential value as a reference potential to measure the potential of other electrodes.
potential value.
3.3 auxiliary electrode Another electrode used to energize the working electrode.
4 Overview
The electrochemical workstation is a multifunctional electrochemical analysis system, which can accurately control the electrochemical reaction potential and According to different methods, changes in signal parameters such as current are detected. There are many kinds of analysis methods, and the commonly used analysis methods are.
Cyclic voltammetry, AC voltammetry, amperometric titration and potentiometric titration, etc. Instruments typically consist primarily of fast digital signals generator, high-speed data acquisition system, potential current signal filter, multi-stage signal gain, IR drop compensation circuit, etc.
And potentiostat, galvanostat and other components.
5 Metrology characteristics the electrochemical workstation calibration items and technical indicators are shown in Table 1.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 12 pages — is available in the English PDF.
How to Download JJF 1910-2021
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Fast delivery
After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
JJF 2425-2026 — Calibration specification for carbon dioxide incubators
JJF 1183-2025 — Calibration Specification for Temperature Transmitters
JJF 1282-2025 — Calibration Specification for Time Delay Relays
JJF 1910-2021
$240.00