JJF 1908-2021Calibration Specification for Bimetal Thermometer (English PDF)
双金属温度计校准规范
This is a limited preview
Buy now to download the full PDF (12 pages)
Need quotation for your management?
Get a formal quotation for JJF 1908-2021 in 30 minutes.
Issued by
State Administration for Market Regulation
Level / Type
National · Mandatory
Issue date
July 28, 2021
Implementation date
January 28, 2022
Scope
JJF 1908-2021 is the English-translated version of 双金属温度计校准规范.
JJF 1908-2021 is the Chinese standard "Calibration Specification for Bimetal Thermometer". Issued on 2021-07-28, in force from 2022-01-28.
Found what you need?
Document preview — JJF 1908-2021
Contents
- 1 Scope(1)
- 2 References (1)
- 3 Terms (1)
- 4 Overview(1)
- 5 Metrology Characteristics(2)
- 5.1 Indication error(2)
- 5.2 Angle adjustment error(2)
- 5.3 Setpoint error(2)
- 5.4 Switching difference(2)
- 5.5 Insulation resistance(2)
- 6 Calibration Conditions(3)
- 6.1 Environmental conditions (3)
- 6.2 Standard device and ancillary equipment (3)
- 7 Calibration items and calibration methods (3)
- 7.1 Calibration and inspection items (3)
- 7.2 Calibration method(4)
- 7.3 Data processing(5)
- 8 Expression of calibration results (6)
- 9 Recalibration interval(6)
- Introduction
1 Scope(1)
2 References (1)
3 Terms (1)
4 Overview(1)
5 Metrology Characteristics(2)
5.1 Indication error(2)
5.2 Angle adjustment error(2)
5.3 Setpoint error(2)
5.4 Switching difference(2)
5.5 Insulation resistance(2)
6 Calibration Conditions(3)
6.1 Environmental conditions (3)
6.2 Standard device and ancillary equipment (3)
7 Calibration items and calibration methods (3)
7.1 Calibration and inspection items (3)
7.2 Calibration method(4)
7.3 Data processing(5)
8 Expression of calibration results (6)
9 Recalibration interval(6)
Appendix A Calibration Record Reference Format(7)
Appendix B Calibration Certificate Results Inner Page Reference Format (8)
Appendix C Example of Uncertainty Evaluation of Indication Error of Bimetal Thermometer (9)
Appendix D Example of Uncertainty Evaluation of Set Point Error of Electric Contact Bimetal Thermometer (12)
Introduction
This specification is compiled in accordance with JJF 1071-2010 "Rules for Compilation of National Metrology and Calibration Specifications".
JJF 1059.1-2012 "Measurement Uncertainty Evaluation and Representation" requires evaluation of uncertainty, refer to in JJF 1007-2007 "Terminology and Definition of Thermometer" and JB/T 8803-2015 "Bimetal Thermometer" related definitions and technical content.
This specification replaces JJG226-2001 "Bimetal Thermometer". Compared with JJG226-2001, except for editorial revisions the main technical changes are as follows.
--- Delete the calibration requirements for hysteresis, indication repeatability, switching repeatability and thermal stability;
--- The calibration standard was updated;
---The technical requirements for constant temperature equipment have changed;
--- Reduce the degree of deviation of the actual temperature of the constant temperature bath from the calibration point during the calibration process;
---Simplifies the calibration method of the set point error of the electric contact thermometer;
--- Reduced the temperature control rate of the constant temperature bath during the calibration process of the set point error;
--- Added the calculation formula of standard platinum resistance thermometer as the measurement standard;
--- An example of uncertainty assessment for calibration of indication error has been updated in the appendix;
--- An example of uncertainty assessment for set point error calibration has been added to the appendix.
The previous releases of this specification are as follows.
---JJG226-2001;
---JJG226-1989.
Bimetal Thermometer Calibration Specifications
1 Scope
This specification applies to the calibration of bimetal thermometers with a measurement range of (-80~500) °C.
2 Reference documents this specification references the following documents.
JB/T 8803-2015 Bimetal Thermometer for dated references, only the dated version applies to this specification; for undated references the latest version (including all amendments) applies to this specification.
3 Terminology
The terms and definitions defined in JB/T 8803-2015 and the following apply to this specification.
A bimetal thermometer that can adjust the angle (0°~90°) between the indicating device and the axis of the detection element.
[Source. JB/T 8803-2015, 3.1] A bimetal thermometer with electrical contacts.
[Source. JB/T 8803-2015, 3.2]
4 Overview
Bimetal thermometer is a temperature instrument suitable for medium and low temperature measurement. It uses two kinds of pure gold with different expansion coefficients.
Metal sheets or alloy sheets are firmly combined to form a temperature sensing element, which is generally wound into a spiral shape, one end of which is fixed, and the other end is fixed.
(Free end) is equipped with a pointer. When the temperature changes, the curvature of the temperature sensing element changes, and the free end rotates to drive the pointer.
The temperature value is indicated on the dial. A protective sleeve is installed on the outside of the temperature sensing element of the bimetal thermometer, and the dial is round.
Its typical structure is shown in Figure 1.
Fig. 1 Schematic diagram of typical structure of bimetal thermometer
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 12 pages — is available in the English PDF.
How to Download JJF 1908-2021
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Fast delivery
After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
JJF 2425-2026 — Calibration specification for carbon dioxide incubators
JJF 1183-2025 — Calibration Specification for Temperature Transmitters
JJF 1282-2025 — Calibration Specification for Time Delay Relays
JJF 1908-2021
$210.00