JJF 1903-2021Calibration Specification for Shock Response Spectrum Testing Machines (English PDF)
冲击响应谱试验机校准规范
This is a limited preview
Buy now to download the full PDF (13 pages)
Need quotation for your management?
Get a formal quotation for JJF 1903-2021 in 30 minutes.
Issued by
State Administration for Market Regulation
Level / Type
National · Mandatory
Issue date
February 23, 2021
Implementation date
August 23, 2021
Scope
JJF 1903-2021 is the English-translated version of 冲击响应谱试验机校准规范.
JJF 1903-2021 is the Chinese standard "Calibration Specification for Shock Response Spectrum Testing Machines". Issued on 2021-02-23, in force from 2021-08-23.
Found what you need?
Document preview — JJF 1903-2021
Contents
- Introduction (II)
- 1 Scope (1)
- 2 Reference documents (1)
- 3 Term (1)
- 4 Overview (1)
- 5 Measurement characteristics (2)
- 6 Calibration conditions (2)
- 7 Calibration items and calibration methods (3)
- 8 Calibration result expression (5)
- 9 Re-calibration interval (5)
- Appendix A Evaluation of Uncertainty of Measurement Results of Impulse Response Spectrum Amplitude (6)
- Appendix B The format of the inner page of the calibration certificate of the shock response spectrum tester (9)
- Appendix C. Indication error of the measurement system of the impulse response spectrum tester (10)
- Appendix D Impulse response spectrum of standard signal (12)
1 Scope (1)
2 Reference documents (1)
3 Term (1)
4 Overview (1)
5 Measurement characteristics (2)
6 Calibration conditions (2)
7 Calibration items and calibration methods (3)
8 Calibration result expression (5)
9 Re-calibration interval (5)
Appendix A Evaluation of Uncertainty of Measurement Results of Impulse Response Spectrum Amplitude (6)
Appendix B The format of the inner page of the calibration certificate of the shock response spectrum tester (9)
Appendix C. Indication error of the measurement system of the impulse response spectrum tester (10)
Appendix D Impulse response spectrum of standard signal (12)
Introduction
This specification is compiled in accordance with the rules stipulated in JJF 1071-2010 "Rules for the Compilation of National Metrology and Calibration Specifications".
In the formulation of this specification, full consideration has been given to JJF 1156-2006 "Measurement Terms and Determination of Vibration and Shock Speed the terms, symbols, and definitions in the Interpretation, as well as GB/T 2423.5-2019 ``Environmental Testing Part 2: Test Method Method Test Ea and Guidelines. Shock, GJB150.18A-2009 "Environmental Test Method for Military Equipment Laboratory No.
Technical requirements for shock response spectrum test and test equipment in Part 18: Impact Test.
This specification is released for the first time.
Calibration specification for shock response spectrum testing machine
1 Scope
This specification applies to the shock response spectrum of the 10kHz frequency range to achieve the maximum absolute acceleration shock response spectrum Calibration of the testing machine.
2 Reference documents the following documents are cited in this specification.
JJF 1156-2006 Vibration impact speed measurement terms and definitions GB/T 2423.5-2019 Environmental Test Part 2: Test Method Test Ea and Guideline. Impact GJB150.18A-2009 Military equipment laboratory environmental test method Part 18: Impact test for dated reference documents, only the dated version applies to this specification; for all undated references the latest version (including all amendments) is applicable to this specification.
3 Term
3.1 Reference spectral shape Absolute acceleration spectrum curve used for calibration or test setting.
3.2 Maximum absolute acceleration shock response spectrum maximumabsolutelyaccelerationshockresponse spectrum with absolute acceleration as the response parameter, the shock response spectrum has the maximum value.
Note. The shock response spectrum mentioned in this specification refers to the maximum absolute acceleration shock response spectrum.
3.3 Shock response spectrum reference tolerance referencetoleranceofshockresponsespectrum Specify the maximum allowable error of the measured impulse response spectrum curve deviating from the reference spectrum shape to determine the impulse response spectrum the baseline of the working state of the testing machine.
Note. The reference tolerance range can be selected as [-1.5dB, 3dB], [-3dB, 3dB], [-6dB, 6dB], [-3dB, 6dB], [-6dB, 9dB], different tolerances can also be used in sections.
4 overview
The shock response spectrum testing machine is used in the shock test of the product, and the shock response spectrum of the product is obtained to determine its Performance under impact environment. There are two main types of equipment for realizing the shock response spectrum test. mechanical shock response spectrum testing machine and Electric vibration desktop shock response spectrum testing machine.
The main principle of the mechanical shock response spectrum testing machine is to use a hammer head to hit the response table to make the hit response table Generate a response environment that simulates shocks. It consists of response table, hammerhead, electronic control system, measuring system and other auxiliary devices composition. The response table is the main structure of the testing machine, which is used to install the specimens and withstand the impact excitation; the main electronic control system the hammer should be controlled by the computer according to the set parameters, and the impact response spectrum should be generated by hitting the response table; the measurement system is under test when the inspection machine is working, the time domain and response spectrum curve of each detection point are measured; other auxiliary devices mainly include driving
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 13 pages — is available in the English PDF.
How to Download JJF 1903-2021
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Fast delivery
After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
JJF 2425-2026 — Calibration specification for carbon dioxide incubators
JJF 1183-2025 — Calibration Specification for Temperature Transmitters
JJF 1282-2025 — Calibration Specification for Time Delay Relays
JJF 1903-2021
$240.00