Valid

JJF 1896-2021Calibration Specification for Electromyographs and Evoked Response Equipment (English PDF)

肌电及诱发反应设备校准规范

Preview PDF

This is a limited preview

Buy now to download the full PDF (13 pages)

Need quotation for your management?

Get a formal quotation for JJF 1896-2021 in 30 minutes.

Issued by

State Administration for Market Regulation

Level / Type

National · Mandatory

Issue date

February 23, 2021

Implementation date

August 23, 2021

Scope

JJF 1896-2021 is the English-translated version of 肌电及诱发反应设备校准规范.

JJF 1896-2021 is the Chinese standard "Calibration Specification for Electromyographs and Evoked Response Equipment". Issued on 2021-02-23, in force from 2021-08-23.

Found what you need?

Document preview — JJF 1896-2021

Contents

  • Introduction (II)
  • 1 Scope (1)
  • 2 Reference documents (1)
  • 3 Terms and units of measurement (1)
  • 3.1 EMG equipment (1)
  • 3.2 Induced response equipment (1)
  • 3.3 Electric stimulator (1)
  • 4 Overview (1)
  • 5 Measurement characteristics (2)
  • 5.1 Waveform amplitude (2)
  • 5.2 Wave frequency (2)
  • 5.3 Common mode rejection ratio (2)
  • 5.4 Amplitude-frequency characteristics (2)
  • 5.5 Stimulus signal frequency (2)
  • 5.6 Stimulus signal intensity (2)
  • 5.7 Stimulation pulse width (2)
  • 6 Calibration conditions (2)
  • 6.1 Environmental conditions (2)
  • 6.2 Measurement standards and other equipment (2)
  • 7 Calibration items and calibration methods (3)
  • 7.1 Appearance and working normality inspection (3)
  • 7.2 Wave amplitude (3)
  • 7.3 Wave frequency (4)
  • 7.4 Common mode rejection ratio (4)
  • 7.5 Amplitude frequency characteristics (5)
  • 7.6 Stimulus signal frequency(5)
  • 7.7 Stimulus signal strength (6)
  • 7.8 Stimulation pulse width (6)
  • 8 Calibration result expression (6)
  • 9 Re-calibration interval (7)
  • Appendix A Original Record Format (8)
  • Appendix B Format of the inner page of the calibration certificate (10)
  • Appendix C Examples of Evaluation of Calibration Uncertainty for Major Items (12)

1 Scope (1)

2 Reference documents (1)

3 Terms and units of measurement (1)

3.1 EMG equipment (1)

3.2 Induced response equipment (1)

3.3 Electric stimulator (1)

4 Overview (1)

5 Measurement characteristics (2)

5.1 Waveform amplitude (2)

5.2 Wave frequency (2)

5.3 Common mode rejection ratio (2)

5.4 Amplitude-frequency characteristics (2)

5.5 Stimulus signal frequency (2)

5.6 Stimulus signal intensity (2)

5.7 Stimulation pulse width (2)

6 Calibration conditions (2)

6.1 Environmental conditions (2)

6.2 Measurement standards and other equipment (2)

7 Calibration items and calibration methods (3)

7.1 Appearance and working normality inspection (3)

7.2 Wave amplitude (3)

7.3 Wave frequency (4)

7.4 Common mode rejection ratio (4)

7.5 Amplitude frequency characteristics (5)

7.6 Stimulus signal frequency(5)

7.7 Stimulus signal strength (6)

7.8 Stimulation pulse width (6)

8 Calibration result expression (6)

9 Re-calibration interval (7)

Appendix A Original Record Format (8)

Appendix B Format of the inner page of the calibration certificate (10)

Appendix C Examples of Evaluation of Calibration Uncertainty for Major Items (12)

Introduction

This specification is based on JJF 1071-2010 "Rules for the Compilation of National Metrology and Calibration Specifications" and JJF 1059.1-2012 "Evaluation and Expression of Measurement Uncertainty" was compiled.

The main technical basis of this specification is YY0896-2013 "Medical Electrical Equipment Part 2: Electromyography and Induced Special requirements for the safety of reaction equipment.

This specification is released for the first time.

Calibration specification for electromyography and evoked response equipment

1 Scope

EMG and evoked response equipment includes EMG equipment and evoked response equipment. This specification applies to EMG and evoked response equipment.

The calibration of the equipment (only for the electrical stimulation part).

2 Reference documents the following documents are cited in this specification.

YY0896-2013 Medical electrical equipment Part 2: Special requirements for the safety of electromyography and evoked response equipment for dated reference documents, only the dated version applies to this specification; for all undated references the latest version (including all amendments) is applicable to this specification.

3 Terms and units of measurement the following terms and definitions defined in YY0896-2013 are applicable to this specification.

3.1 Electromyograph [YY0896-2013,2.1.101] Medical electrical equipment used to detect and analyze bioelectrical potentials related to nerve and muscle activity.

The activity may be spontaneous, or it may be stimulated by electricity or other stimuli.

3.2 Evoked response equipment [YY0896-2013,2.1.102] Medical electrical equipment used to detect and analyze the bioelectric potential generated by induced stimuli. The stimulus may be electric shock or touch.

Touch, hearing, sight, smell, etc.

3.3 Electricalstimulator electricalstimulator[YY0896-2013,2.1.103] Device parts that conduct current by using electrodes that are in direct contact with the patient, used to stimulate biopotential or other reaction.

4 overview

Electromyography equipment and evoked response equipment use electrodes to obtain the muscle telecommunication induced by the body itself or the stimulator.

No., a device that displays after being amplified by a signal amplifier and processed by an operational controller. Clinically, it is mainly used to treat God the system and muscle function are evaluated to determine the location, nature and extent of related diseases. Electrical stimulators and signals the amplifier is its core component. The structural block diagram is shown as in Fig. 1.

Figure 1 Block diagram of electromyography equipment and evoked response equipment

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 13 pages — is available in the English PDF.

How to Download JJF 1896-2021

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Fast delivery

    After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
13 pages
Fast delivery
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

JJF 1896-2021

$345.00