JJF 1894-2021Calibration Specification for Calibrators of Semiconductor Curve Tracers (English PDF)
半导体管特性图示仪校准仪校准规范
This is a limited preview
Buy now to download the full PDF (17 pages)
Need quotation for your management?
Get a formal quotation for JJF 1894-2021 in 30 minutes.
Issued by
State Administration for Market Regulation
Level / Type
National · Mandatory
Issue date
February 23, 2021
Implementation date
August 23, 2021
Scope
JJF 1894-2021 is the English-translated version of 半导体管特性图示仪校准仪校准规范.
JJF 1894-2021 is the Chinese standard "Calibration Specification for Calibrators of Semiconductor Curve Tracers". Issued on 2021-02-23, in force from 2021-08-23.
Found what you need?
Document preview — JJF 1894-2021
Contents
- Introduction (II)
- 1 Scope (1)
- 2 Overview (1)
- 3 Measurement characteristics (1)
- 3.1 Output part (1)
- 3.2 Sampling resistance (1)
- 3.3 Measurement part (1)
- 4 Calibration conditions (2)
- 4.1 Environmental conditions (2)
- 4.2 Equipment for calibration (2)
- 5 Calibration items and calibration methods (3)
- 5.1 Calibration items (3)
- 5.2 Calibration method (3)
- 6 Calibration result expression (6)
- 7 Re-calibration interval (6)
- Appendix A Original Record Format (7)
- Appendix B Format of the inner page of the calibration certificate (10)
- Appendix C Examples of Evaluation of Calibration Uncertainty for Major Items (13)
- Appendix D Definition of Ports of Calibrator for Semiconductor Tube Characteristic Grapher (20)
1 Scope (1)
2 Overview (1)
3 Measurement characteristics (1)
3.1 Output part (1)
3.2 Sampling resistance (1)
3.3 Measurement part (1)
4 Calibration conditions (2)
4.1 Environmental conditions (2)
4.2 Equipment for calibration (2)
5 Calibration items and calibration methods (3)
5.1 Calibration items (3)
5.2 Calibration method (3)
6 Calibration result expression (6)
7 Re-calibration interval (6)
Appendix A Original Record Format (7)
Appendix B Format of the inner page of the calibration certificate (10)
Appendix C Examples of Evaluation of Calibration Uncertainty for Major Items (13)
Appendix D Definition of Ports of Calibrator for Semiconductor Tube Characteristic Grapher (20)
Introduction
This specification is based on JJF 1071-2010 "Rules for the Compilation of National Metrology and Calibration Specifications" and JJF 1059.1-2012 "Evaluation and Expression of Measurement Uncertainty" was compiled.
This specification is revised on the basis of JJG838-1993 "Transistor Characteristic Graphic Instrument Calibrator". versus Compared with JJG838-1993, in addition to editorial changes, the main technical changes are as follows.
--- Modify the name of the specification to "Semiconductor Tube Characteristic Grapher Calibrator Calibration Specification";
---Revised the calibration items;
---Added the calibration method of the ladder voltmeter;
---Added the calibration method of the ladder ammeter;
---The calibration method of pulse ammeter has been added;
---The uncertainty evaluation method of level measurement is given in the appendix (see appendix C);
---The definition of the calibrator port of the semiconductor tube characteristic diagram instrument is given in the appendix (see appendix D).
The release status of previous versions of this specification.
---JJG838-1993.
Calibration specification for calibrator of semiconductor tube characteristic diagram instrument
1 Scope
This specification applies to the calibration of the calibrator of the semiconductor tube characteristic diagram instrument.
2 overview
The calibrator of the semiconductor tube characteristic graph instrument (hereinafter referred to as the graph instrument calibrator) is to provide standard voltage source, standard Standard signal such as quasi-current source is a special calibration instrument for calibrating the semiconductor tube characteristic graph instrument. There are currently two main types Type. Ladder normalization graph instrument calibrator and step sampling measurement graph instrument calibrator. Step normalization graph instrument calibration the internal stepped normalization comparison method is used to calibrate the graphical instrument, and the internal calibration instrument of the stepped sampling measurement graphical instrument is used.
The step sampling method is used to calibrate the graphic instrument.
3 Metrological characteristics
3.1 Output section
3.1.1 DC voltage
a) Output range. 0.01V~5000V;
b) Maximum allowable error. ± (0.3%~3%).
3.1.2 DC current
a) Output range. 10nA~10A;
b) Maximum allowable error. ± (0.3%~3%).
3.2 Sampling resistance
a) Range. 0.005ohm~10Mohm;
b) Maximum allowable error. ± (0.3%~1%).
3.3 Measurement part
3.3.1 Step voltage normalization transformation
a) V0 voltage conversion range. 0.1V~20V;
b) Maximum allowable error. ±0.3%.
3.3.2 Step current normalization transformation
a) Is current conversion range. 10µA~20A;
b) Maximum allowable error. ±0.3%.
3.3.3 Deviation table
a) Measuring range. ± (3%~10%);
b) Maximum allowable error. ±0.5%.
3.3.4 Step voltage indication
a) V0 voltage conversion range. 0.01V/step~10V/step;
b) Maximum allowable error. ± (0.3%~1%).
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 17 pages — is available in the English PDF.
How to Download JJF 1894-2021
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Fast delivery
After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
JJF 2425-2026 — Calibration specification for carbon dioxide incubators
JJF 1183-2025 — Calibration Specification for Temperature Transmitters
JJF 1282-2025 — Calibration Specification for Time Delay Relays
JJF 1894-2021
$360.00