JJF 1892-2021Calibration Specification for Insufflators (English PDF)
气腹机校准规范
This is a limited preview
Buy now to download the full PDF (10 pages)
Need quotation for your management?
Get a formal quotation for JJF 1892-2021 in 30 minutes.
Issued by
State Administration for Market Regulation
Level / Type
National · Mandatory
Issue date
February 23, 2021
Implementation date
August 23, 2021
Scope
JJF 1892-2021 is the English-translated version of 气腹机校准规范.
JJF 1892-2021 is the Chinese standard "Calibration Specification for Insufflators". Issued on 2021-02-23, in force from 2021-08-23.
Found what you need?
Document preview — JJF 1892-2021
Contents
- Introduction (II)
- 1 Scope (1)
- 2 Reference documents (1)
- 3 Terms and units of measurement (1)
- 4 Overview (1)
- 5 Measurement characteristics (2)
- 5.1 Air pressure setting error (2)
- 5.2 Error of barometric pressure display value (2)
- 5.3 Overpressure alarm air pressure difference (2)
- 5.4 Error of flow setting value (2)
- 5.5 Error of flow display value (2)
- 6 Calibration conditions (2)
- 6.1 Environmental conditions (2)
- 6.2 Measurement standards and other equipment (2)
- 7 Calibration items and calibration methods (3)
- 7.1 Visual inspection (3)
- 7.2 Functional inspection and preparation before calibration (3)
- 7.3 Air pressure setting error (3)
- 7.4 Error of barometric pressure display value (3)
- 7.5 Overpressure alarm air pressure difference (4)
- 7.6 Error of flow setting value (4)
- 7.7 Error of flow display value (4)
- 8 Calibration result expression (5)
- 8.1 Calibration record (5)
- 8.2 Processing of calibration results (5)
- 9 Re-calibration interval (5)
- Appendix A Insufflator calibration record format (6)
- Appendix B. Internal page format of calibration certificate (8)
- Appendix C Evaluation Example of Measurement Uncertainty (9)
1 Scope (1)
2 Reference documents (1)
3 Terms and units of measurement (1)
4 Overview (1)
5 Measurement characteristics (2)
5.1 Air pressure setting error (2)
5.2 Error of barometric pressure display value (2)
5.3 Overpressure alarm air pressure difference (2)
5.4 Error of flow setting value (2)
5.5 Error of flow display value (2)
6 Calibration conditions (2)
6.1 Environmental conditions (2)
6.2 Measurement standards and other equipment (2)
7 Calibration items and calibration methods (3)
7.1 Visual inspection (3)
7.2 Functional inspection and preparation before calibration (3)
7.3 Air pressure setting error (3)
7.4 Error of barometric pressure display value (3)
7.5 Overpressure alarm air pressure difference (4)
7.6 Error of flow setting value (4)
7.7 Error of flow display value (4)
8 Calibration result expression (5)
8.1 Calibration record (5)
8.2 Processing of calibration results (5)
9 Re-calibration interval (5)
Appendix A Insufflator calibration record format (6)
Appendix B. Internal page format of calibration certificate (8)
Appendix C Evaluation Example of Measurement Uncertainty (9)
Introduction
The compilation of this specification is based on JJF 1071-2010 "Rules for the Compilation of National Metrology and Calibration Specifications", JJF 1001-2011 "General Metrology Terms and Definitions", JJF 1059.1-2012 "Evaluation and Expression of Measurement Uncertainty" as the basis and in accordance with.
The formulation of this specification refers to YY0843-2011 "Medical Endoscope Endoscope Function Supply Device Pneumoperitoneum" machine".
This specification is released for the first time.
Insufflator calibration specification
1 Scope
This specification applies to the calibration of the measurement characteristics of the insufflator.
2 Reference documents the following documents are cited in this specification.
GB 9706.1 Medical electrical equipment Part 1: General requirements for basic safety and basic performance GB 9706.19 Medical electrical equipment Part 2: Special requirements for the safety of endoscopic equipment YY0843-2011 medical endoscope endoscopic function supply device pneumoperitoneum machine for dated reference documents, only the dated version applies to this specification; for all undated references the latest version (including all amendments) is applicable to this specification.
3 Terms and units of measurement
3.1 Gaspressureofover-pressurealarm Simulate the actual pressure value in the abdominal cavity when an overpressure alarm occurs in the insufflator, in Pa or mmHg (mmHg).
3.2 Gaspressuredifferenceofoverpressurealarm the difference between the overpressure alarm air pressure and the corresponding air pressure setting value, in Pa or millimeter mercury (mmHg).
3.3 Abdominal cavity simulator A device that can simulate the characteristics of the patient's abdominal cavity.
3.4 (gascharging) scalefactor Simulate the volume change per unit pressure in the abdominal cavity, in units of liters per pascal (L/Pa) or liters per millimeter of mercury Column (L/mmHg).
4 overview
Pneumoperitoneum machine is a special device used to establish and maintain pneumoperitoneum in abdominal endoscopic surgery. It is mainly in laparoscopy During the inspection and surgery, medical carbon dioxide gas is injected into the abdominal cavity, and the abdominal wall is separated from the abdominal internal organs with the gas to form Surgical operation and visual field space. When it reaches a predetermined pressure, it can automatically stop the air intake and maintain a certain amount of gas to make the abdominal cavity the inside has been in a predetermined pressure inflation state. When the air pressure in the abdominal cavity decreases during the operation, it can automatically inflate to maintain the hand Necessary operation and observation space required for surgical operation. The establishment of pneumoperitoneum is the basis of laparoscopic surgery, and the maintenance of pneumoperitoneum depends on the normal operation of the insufflator.
The insufflator is composed of an air intake tube, a main engine, a pneumoperitoneum tube, a filter, and a pneumoperitoneum needle. The main engine is mainly composed of decompression system System, solenoid valve, air pressure sensor, flow sensor, safety valve, power supply and display device.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 10 pages — is available in the English PDF.
How to Download JJF 1892-2021
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Fast delivery
After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
JJF 2425-2026 — Calibration specification for carbon dioxide incubators
JJF 1183-2025 — Calibration Specification for Temperature Transmitters
JJF 1282-2025 — Calibration Specification for Time Delay Relays
JJF 1892-2021
$210.00