JJF 1891-2021Calibration Specification for Medical Oxygen Generators with Molecular Sieve (English PDF)

医用分子筛制氧机校准规范

Preview PDF

This is a limited preview

Buy now to download the full PDF (11 pages)

Need quotation for your management?

Get a formal quotation for JJF 1891-2021 in 30 minutes.

Issued by

State Administration for Market Regulation

Level / Type

National · Mandatory

Issue date

February 23, 2021

Implementation date

August 23, 2021

Scope

JJF 1891-2021 is the English-translated version of 医用分子筛制氧机校准规范.

JJF 1891-2021 is the Chinese standard "Calibration Specification for Medical Oxygen Generators with Molecular Sieve". Issued on 2021-02-23, in force from 2021-08-23.

Found what you need?

Document preview — JJF 1891-2021

Contents

  • Introduction (II)
  • 1 Scope (1)
  • 2 Reference documents (1)
  • 3 Terms and units of measurement (1)
  • 3.1 Molecular sieve (1)
  • 3.2 Adsorption (1)
  • 3.3 Desorption (1)
  • 3.4 Pressure swing adsorption (1)
  • 3.5 Molecular sieve for oxygen production (1)
  • 3.6 Dew point(1)
  • 3.7 Maximum recommended flow (1)
  • 4 Overview (2)
  • 5 Measurement characteristics (2)
  • 5.1 Flow rate indication error (2)
  • 5.2 Oxygen concentration of output gas (2)
  • 5.3 Moisture content of output gas (2)
  • 5.4 Carbon dioxide content of output gas (2)
  • 5.5 Carbon monoxide content of output gas (2)
  • 6 Calibration conditions (3)
  • 6.1 Environmental conditions (3)
  • 6.2 Measurement standards and other equipment (3)
  • 7 Calibration items and calibration methods (3)
  • 7.1 Flow rate indication error (3)
  • 7.2 Oxygen concentration of output gas (4)
  • 7.3 Moisture content of output gas (4)
  • 7.4 Carbon dioxide content of output gas (4)
  • 7.5 Carbon monoxide content of output gas (4)
  • 8 Calibration result expression (4)
  • 8.1 Calibration record (4)
  • 8.2 Calibration certificate (4)
  • 9 Re-calibration interval (5)
  • Appendix A Original record (reference) format of medical molecular sieve oxygen generator (6)
  • Appendix B. The result page (reference) format of the calibration certificate of medical molecular sieve oxygen generator (7)
  • Appendix C Evaluation Example of Uncertainty of Measurement Results (8)
  • Appendix D Unit Conversion Table of Dew Point Temperature and Absolute Humidity and Volume Ratio (10)

1 Scope (1)

2 Reference documents (1)

3 Terms and units of measurement (1)

3.1 Molecular sieve (1)

3.2 Adsorption (1)

3.3 Desorption (1)

3.4 Pressure swing adsorption (1)

3.5 Molecular sieve for oxygen production (1)

3.6 Dew point(1)

3.7 Maximum recommended flow (1)

4 Overview (2)

5 Measurement characteristics (2)

5.1 Flow rate indication error (2)

5.2 Oxygen concentration of output gas (2)

5.3 Moisture content of output gas (2)

5.4 Carbon dioxide content of output gas (2)

5.5 Carbon monoxide content of output gas (2)

6 Calibration conditions (3)

6.1 Environmental conditions (3)

6.2 Measurement standards and other equipment (3)

7 Calibration items and calibration methods (3)

7.1 Flow rate indication error (3)

7.2 Oxygen concentration of output gas (4)

7.3 Moisture content of output gas (4)

7.4 Carbon dioxide content of output gas (4)

7.5 Carbon monoxide content of output gas (4)

8 Calibration result expression (4)

8.1 Calibration record (4)

8.2 Calibration certificate (4)

9 Re-calibration interval (5)

Appendix A Original record (reference) format of medical molecular sieve oxygen generator (6)

Appendix B. The result page (reference) format of the calibration certificate of medical molecular sieve oxygen generator (7)

Appendix C Evaluation Example of Uncertainty of Measurement Results (8)

Appendix D Unit Conversion Table of Dew Point Temperature and Absolute Humidity and Volume Ratio (10)

Introduction

The compilation of this specification is based on JJF 1071-2010 "Rules for the Compilation of National Metrology and Calibration Specifications", JJF 1001-2011 "General Metrology Terms and Definitions" and JJF 1059.1-2012 "Evaluation and Expression of Measurement Uncertainty" as the basis and in accordance with.

This specification is released for the first time.

Calibration specification for medical molecular sieve oxygen generator

1 Scope

This specification applies to the calibration of the measurement characteristics of small medical molecular sieve oxygen generators with continuous oxygen supply.

A medical molecular sieve oxygen production system with a piped medical gas device that supplies gas to several patients is also not suitable for flammable anesthesia Medical molecular sieve oxygen generator used under gas or cleaning agent conditions.

2 Reference documents the following documents are cited in this specification.

GB/T 5832.2-2016 Determination of trace moisture in gas analysis Part 2: Dew point method GB/T 11605-2005 Humidity measurement method GB/T 33032-2016 Molecular Sieve Terminology YY/T 0298-1998 General technical specifications for medical molecular sieve oxygen production equipment YY0732-2009 Safety requirements for medical oxygen concentrators YY1468-2016 Oxygen concentrator gas supply system for medical gas pipeline system for dated reference documents, only the dated version applies to this specification; for all undated references the latest version (including all amendments) is applicable to this specification.

3 Terms and units of measurement GB/T 33032-2016, GB/T 5832.2-2016 and YY/T 0298-1998 and the following techniques the terms and definitions apply to this specification.

3.1 Molecular sieve A type of solid material with uniform micropores and the pore size is equivalent to the general molecular size.

3.2 adsorption

When the gas phase (or liquid phase) and the solid phase form an adsorption system (adsorption phase), the components at the phase interface are enriched phenomenon.

3.3 desorption

A phenomenon in which the molecules of the gas (or liquid) that have been adsorbed by the adsorbent are released back to the gas (or liquid) phase.

3.4 pressureswingadsorption; PSA Cycle operation process of pressure adsorption and decompression desorption.

3.5 Molecular sieve for oxygen generation the adsorption of nitrogen is greater than the adsorption of oxygen, molecular sieve that can adsorb and separate nitrogen and oxygen.

3.6 dewpoint

The temperature at which unsaturated air or other humidity is cooled to a saturated state.

3.7 Maximum recommended flow the maximum flow rate stated or recommended by the equipment manufacturer on the manual or on the nameplate of the instrument, in liters per minute (L/min).

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 11 pages — is available in the English PDF.

How to Download JJF 1891-2021

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Fast delivery

    After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
11 pages
Fast delivery
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

JJF 1891-2021

$240.00