Scope
JJF 1885-2020 (Calibration Specification for RF and Microwave Power Meters) is available as an English-translated PDF.
JJF 1885-2020 — This standard applies to the calibration of various types of radio frequency and microwave power meters with a frequency range of 9 kHz to 50 GHz and a power range of -70 dBm to 20 dBm.
Found what you need?
Document preview — JJF 1885-2020
National Standard of the People's Republic of China
- ICS
- 17.220
- Classification
- A 56
Issued by: State Administration for Market Regulation
Contents
- Introduction (II)
- 1 Scope (1)
- 2 Overview (1)
- 3 Measurement characteristics (1)
- 3.1 Reference source power(1)
- 3.2 Calibration factor (K) (1)
- 3.3 Linearity (1)
- 3.4 Voltage standing wave ratio (1)
- 4 Calibration conditions (1)
- 4.1 Environmental conditions (1)
- 4.2 Calibration equipment (1)
- 5 Calibration items and calibration methods (2)
- 5.1 Calibration items (2)
- 5.2 Appearance and working normality inspection (2)
- 5.3 Reference source power(3)
- 5.4 Calibration factor (3)
- 5.5 Linearity (4)
- 5.6 Voltage standing wave ratio (5)
- 6 Calibration result expression (5)
- 7 Re-calibration interval (6)
- Appendix A Original Record Format (7)
- Appendix B Internal page format of calibration certificate (9)
- Appendix C Examples of Evaluation of Calibration Uncertainty for Major Items (10)
1 Scope (1)
2 Overview (1)
3 Measurement characteristics (1)
3.1 Reference source power(1)
3.2 Calibration factor (K) (1)
3.3 Linearity (1)
3.4 Voltage standing wave ratio (1)
4 Calibration conditions (1)
4.1 Environmental conditions (1)
4.2 Calibration equipment (1)
5 Calibration items and calibration methods (2)
5.1 Calibration items (2)
5.2 Appearance and working normality inspection (2)
5.3 Reference source power(3)
5.4 Calibration factor (3)
5.5 Linearity (4)
5.6 Voltage standing wave ratio (5)
6 Calibration result expression (5)
7 Re-calibration interval (6)
Appendix A Original Record Format (7)
Appendix B Internal page format of calibration certificate (9)
Appendix C Examples of Evaluation of Calibration Uncertainty for Major Items (10)
Introduction
This specification is based on JJF 1071-2010 "Rules for the Compilation of National Metrology and Calibration Specifications" and JJF 1059.1-2012 "Evaluation and Expression of Measurement Uncertainty" was compiled:
This specification is released for the first time:
Radio frequency and microwave power meter calibration specifications
1 Scope
This specification is applicable to various types with a frequency range of 9kHz~50GHz and a power range of -70dBm~20dBm Types of radio frequency and microwave power meter calibration, other frequency range radio frequency and microwave power meter calibration can be used as a reference:
2 overview
The RF and microwave power meter (hereinafter referred to as the power meter) consists of the conversion part and Corresponding measurement and indicator components are used to convert radio frequency or microwave signals into DC or low frequency signals to be measured and the principle of indication completes the measurement of radio frequency and microwave power:
3 Metrological characteristics
3.1 Reference source power Output power: 1mW (50MHz);
Maximum allowable error of output power: ±0.5%:
3.2 Calibration factor (K) Frequency range: 9kHz~50GHz;
Calibration factor measurement uncertainty: 0.5%~5% (k=2):
3.3 Linearity
Calibration frequency: 50MHz;
Power range: -20dBm~ 10dBm;
Linearity measurement uncertainty: 0:04dB~0:1dB (k=2):
3.4 Voltage standing wave ratio Frequency range: 9kHz~50GHz;
Measurement uncertainty: 0:02~0:03 (k=2):
Note: The above technical indicators are not for eligibility judgment, only for reference:
4 Calibration conditions
4.1 Environmental conditions Ambient temperature: (23±5)°C, the temperature fluctuation does not exceed 1°C during calibration;
Relative humidity: not more than 80%;
Power requirements: voltage (220 ± 11) V, frequency (50 ± 1) Hz;
Other: There is no mechanical vibration and electromagnetic interference that affect the normal operation of the calibration system:
4.2 Equipment for calibration
4.2.1 Signal generator
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 13 pages — is available in the English PDF.
How to Download JJF 1885-2020
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
JJF 2425-2026 — Calibration specification for carbon dioxide incubators
JJF 1183-2025 — Calibration Specification for Temperature Transmitters
JJF 1282-2025 — Calibration Specification for Time Delay Relays
Secure payment via Stripe
Payments accepted
JJF 1885-2020
$385.00