JJF 1878-2020Calibration Specification for On-line Monitoring Devices of Capacitive Equipment (English PDF)
This is a limited preview
Buy now to download the full PDF (15 pages)
Need quotation for your management?
Get a formal quotation for JJF 1878-2020 in 30 minutes.
Issued by
State Administration for Market Regulation
Level / Type
National · Mandatory
Issue date
November 26, 2020
Implementation date
May 26, 2021
Scope
JJF 1878-2020 (Calibration Specification for On-line Monitoring Devices of Capacitive Equipment) is available as an English-translated PDF.
JJF 1878-2020 — This standard applies to the calibration of online monitoring devices for high-voltage electrical equipment with capacitive insulation structures (hereinafter referred to as "monitoring devices").
Found what you need?
Document preview — JJF 1878-2020
National Standard of the People's Republic of China
- ICS
- 17.220
- Classification
- A 55
Issued by: State Administration for Market Regulation
Contents
- Introduction (II)
- 1 Scope (1)
- 2 Reference documents (1)
- 3 Term (1)
- 4 Overview (1)
- 5 Measurement characteristics (2)
- 5.1 Reference voltage (2)
- 5.2 Full current (2)
- 5.3 Dielectric loss factor (2)
- 5.4 Electric capacity(2)
- 6 Calibration conditions (2)
- 6.1 Environmental conditions (2)
- 6.2 Measurement standards and auxiliary equipment (3)
- 7 Calibration items and calibration methods (3)
- 7.1 Calibration items (3)
- 7.2 Calibration method (4)
- 8 Calibration result expression (6)
- 8.1 Data processing (6)
- 8.2 Calibration certificate (6)
- 9 Recheck interval (7)
- Appendix A Calibration method of monitoring device after installation and in operation (8)
- Appendix B: Calibration Original Record Format (10)
- Appendix C Internal page format of calibration certificate (13)
- Appendix D Examples of Measurement Uncertainty Evaluation (16)
1 Scope (1)
2 Reference documents (1)
3 Term (1)
4 Overview (1)
5 Measurement characteristics (2)
5.1 Reference voltage (2)
5.2 Full current (2)
5.3 Dielectric loss factor (2)
5.4 Electric capacity(2)
6 Calibration conditions (2)
6.1 Environmental conditions (2)
6.2 Measurement standards and auxiliary equipment (3)
7 Calibration items and calibration methods (3)
7.1 Calibration items (3)
7.2 Calibration method (4)
8 Calibration result expression (6)
8.1 Data processing (6)
8.2 Calibration certificate (6)
9 Recheck interval (7)
Appendix A Calibration method of monitoring device after installation and in operation (8)
Appendix B: Calibration Original Record Format (10)
Appendix C Internal page format of calibration certificate (13)
Appendix D Examples of Measurement Uncertainty Evaluation (16)
Introduction
JJF 1001-2011 "General Metrology Terms and Definitions", JJF 1059.1-2012 "Measuring Uncertainty Evaluation and Representation" and JJF 1071-2010 "Rules for the Compilation of National Metrology and Calibration Specifications" together constitute the foundation supporting this specification Series specifications: This specification refers to DL/T 1562-2016 "Calibration Specification for Capacitive Equipment Monitoring Device":
This specification is released for the first time:
Calibration specification for online monitoring device of capacitive equipment
1 Scope
This specification applies to online monitoring devices for high-voltage electrical equipment with capacitive insulation structures (hereinafter referred to as "monitoring devices"):
Set") calibration:
2 Reference documents this specification refers to the following documents:
DL/T 1562-2016 Calibration specification for capacitive equipment monitoring device for dated reference documents, only the dated version applies to the specification; for undated references the latest version (including all amendments) is applicable to this specification:
3 term
3.1 Capacitive equipment High-voltage electrical equipment with capacitive insulation structure:
3.2 Online monitoring device A device used for continuous monitoring and measurement of high-voltage equipment without power failure:
3.3 (of the monitoring device) reference voltage (ofthemonitoringdevice) the voltage used as the phase reference when measuring the dielectric loss factor: This voltage is obtained through the secondary side of the voltage transformer:
It is often power frequency 100V/3 or 100V:
3:4 totalcurrent
The total current through the current acquisition unit of the monitoring device:
4 overview
The monitoring device measures the full current I, dielectric loss factor D and reference voltage U of the capacitive equipment, etc:
To reflect the insulation status of capacitive equipment in real time: The monitoring device consists of a reference voltage acquisition unit, a full current acquisition unit, Signal processing and analysis unit, communication display unit: Its working principle is shown in Figure 1:
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.
How to Download JJF 1878-2020
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
JJF 2425-2026 — Calibration specification for carbon dioxide incubators
JJF 1183-2025 — Calibration Specification for Temperature Transmitters
JJF 1282-2025 — Calibration Specification for Time Delay Relays
Secure payment via Stripe
Payments accepted
JJF 1878-2020
$330.00