Valid

JJF 1828-2020Calibration Specification for Adenosine Triphosphate (ATP)Fluorescence Detectors (English PDF)

ATP荧光检测仪校准规范

Preview PDF

This is a limited preview

Buy now to download the full PDF (17 pages)

Need quotation for your management?

Get a formal quotation for JJF 1828-2020 in 30 minutes.

Issued by

State Administration for Market Regulation

Level / Type

National · Mandatory

Issue date

January 1, 2020

Implementation date

April 17, 2020

Scope

JJF 1828-2020 is the English-translated version of ATP荧光检测仪校准规范.

JJF 1828-2020 is the Chinese standard "Calibration Specification for Adenosine Triphosphate (ATP)Fluorescence Detectors".

Found what you need?

Document preview — JJF 1828-2020

National Standard of the People's Republic of China

ICS
17.020

Contents

  • Introduction (II)
  • 1 Scope (1)
  • 2 References (1)
  • 3 Terms and units of measurement (1)
  • 3.1 Relative light unit (1)
  • 4 Overview (1)
  • 5 Metrological characteristics (1)
  • 5.1 Background noise value (1)
  • 5.2 Limit of detection (1)
  • 5.3 Linear range and correlation coefficient (1)
  • 5.4 Repeatability (1)
  • 5.5 Relative indication error (2)
  • 6 Calibration conditions (2)
  • 6.1 Environmental conditions (2)
  • 6.2 Reference materials, test swabs or reagents, instruments (2)
  • 7 Calibration items and calibration methods (2)
  • 7.1 Background noise value (2)
  • 7.2 Limit of detection (3)
  • 7.3 Linear range and correlation coefficient (3)
  • 7.4 Repeatability (4)
  • 7.5 Linearity error (5)
  • 8 Expression of calibration results (6)
  • 9 Recalibration interval (6)
  • Appendix A. Preparation of ATP Standard Working Solutions (7)
  • Appendix B. Linear Error Calibration Uncertainty Evaluation Example of ATP Substance Measurement (8)
  • Appendix C. Examples of Uncertainty Evaluation of Linear Error Calibration for Luminance Measurement (13)
  • Appendix D. ATP Calibration Original Record Format (Recommended Form) (16)
  • Appendix E. Original Recording Format of Calibration Method for Adjustable Low Light Generator (Recommended Form) (18)
  • Appendix F Calibration Certificate (Inner Page) Format (Recommended Form) (20)

1 Scope (1)

2 References (1)

3 Terms and units of measurement (1)

3.1 Relative light unit (1)

4 Overview (1)

5 Metrological characteristics (1)

5.1 Background noise value (1)

5.2 Limit of detection (1)

5.3 Linear range and correlation coefficient (1)

5.4 Repeatability (1)

5.5 Relative indication error (2)

6 Calibration conditions (2)

6.1 Environmental conditions (2)

6.2 Reference materials, test swabs or reagents, instruments (2)

7 Calibration items and calibration methods (2)

7.1 Background noise value (2)

7.2 Limit of detection (3)

7.3 Linear range and correlation coefficient (3)

7.4 Repeatability (4)

7.5 Linearity error (5)

8 Expression of calibration results (6)

9 Recalibration interval (6)

Appendix A. Preparation of ATP Standard Working Solutions (7)

Appendix B. Linear Error Calibration Uncertainty Evaluation Example of ATP Substance Measurement (8)

Appendix C. Examples of Uncertainty Evaluation of Linear Error Calibration for Luminance Measurement (13)

Appendix D. ATP Calibration Original Record Format (Recommended Form) (16)

Appendix E. Original Recording Format of Calibration Method for Adjustable Low Light Generator (Recommended Form) (18)

Appendix F Calibration Certificate (Inner Page) Format (Recommended Form) (20)

Introduction

This specification is written in accordance with the requirements of JJF 1071-2010 "Rules for Compiling National Measurement and Calibration Specifications".

This specification mainly refers to ASTM D7463-14a "fuel, fuel/water mixture, fuel-related microbiology Standard Test Method for the Adenosine Triphosphate (ATP) Content "StandardTestMethodforAdenosine Triphosphate (ATP) ContentofMicroorganismsinFuel, Fuel/WaterMixtures, and FuelAssociatedWater] formulation.

This specification is the first release.

Calibration specification for ATP fluorescence detector

1 Scope

This specification applies to the calibration of handheld and desktop ATP fluorescence detectors.

2 Reference documents this specification refers to the following documents.

ASTMD7463-14a fuel, fuel/water mixture, fuel-related microbial adenosine triphosphate in water (ATP) content standard detection method [StandardTestMethodforAdenosineTriphosphate (ATP) ContentofMicroorganismsinFuel, Fuel/WaterMixtures, andFuelAssociatedWater] for dated reference documents, only the dated version applies to this specification; for those without date references the latest version (including all amendments) is applicable to this specification.

3 Terms and units of measurement 3.1 relative light unit; RLU [ASTMD7463-14a, 3.1.19] Adenosine Triphosphate (ATP) is hydrolyzed to Adenosine Monophosphate (AMP) and pyrophosphate release chemical energy to drive the oxidative release of luciferin catalyzed by luciferase the unit of measurement of the light quantum number that is put.

Note. Not a SI unit, but proportional to the ATP concentration. Different detectors may produce different values for the same photon number the same RLU reading.

4 Overview

The ATP fluorescence detector (hereinafter referred to as the instrument) consists of a detection chamber, a control panel, and a photoelectric detector (avalanche diode) Tube or photomultiplier tube detector, etc.) and data acquisition signal processing system, etc., and equipped with supporting fluorescent Swab or reagent of a mixture of luciferin and luciferase. After collecting ATP in the sample, mix it with luciferin and luciferase the biological reaction will produce bioluminescence around 550nm. Within a suitably low ATP concentration range, the luminous intensity is the ATP concentration is proportional. According to the relative light unit RLU, the sample can be deduced from food residues and microorganisms the degree of pollution is monitored for overall cleanliness.

The instrument can be divided into handheld and desktop.

5 Metrological characteristics

5.1 Background noise value

5.2 Limit of detection

5.3 Linear range and correlation coefficient

5.4 Repeatability

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 17 pages — is available in the English PDF.

How to Download JJF 1828-2020

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Fast delivery

    After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
17 pages
Fast delivery
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

JJF 1828-2020

$465.00