Valid

JJF 1827-2020Calibration Specification for Cement Fineness Negative Pressure Screen Analyzers (English PDF)

水泥细度负压筛析仪校准规范

Preview PDF

This is a limited preview

Buy now to download the full PDF (11 pages)

Need quotation for your management?

Get a formal quotation for JJF 1827-2020 in 30 minutes.

Issued by

State Administration for Market Regulation

Level / Type

National · Mandatory

Issue date

January 1, 2020

Implementation date

April 17, 2020

Scope

JJF 1827-2020 is the English-translated version of 水泥细度负压筛析仪校准规范.

JJF 1827-2020 is the Chinese standard "Calibration Specification for Cement Fineness Negative Pressure Screen Analyzers".

Found what you need?

Document preview — JJF 1827-2020

National Standard of the People's Republic of China

ICS
17.100

Contents

  • Introduction (II)
  • 1 Scope (1)
  • 2 Reference documents (1)
  • 3 Terms and measurement units (1)
  • 3.1 Term (1)
  • 3.2 Unit of measurement(1)
  • 4 Overview (1)
  • 5 Measurement characteristics (2)
  • 5.1 Measuring range (2)
  • 5.2 Indication error (2)
  • 5.3 Return error (2)
  • 5.4 Insulation resistance (2)
  • 5.5 Noise (2)
  • 5.6 Speed (2)
  • 6 Calibration conditions (2)
  • 6.1 Environmental conditions (2)
  • 6.2 Measurement standards and other equipment (2)
  • 7 Calibration items and calibration methods (2)
  • 7.1 Appearance and functional inspection (2)
  • 7.2 Indication error (3)
  • 7.3 Return error (3)
  • 7.4 Insulation resistance (3)
  • 7.5 Noise(3)
  • 7.6 Speed(4)
  • 8 Calibration result expression (4)
  • 8.1 Calibration data processing (4)
  • 8.2 Calibration certificate (4)
  • 8.3 Evaluation of calibration uncertainty (4)
  • 9 Re-calibration interval (4)
  • Appendix A Original record of calibration of cement fineness negative pressure sieve analyzer (recommended style) (5)
  • Appendix B Inside page of calibration certificate (recommended style) (6)
  • Appendix C Example of Uncertainty Evaluation of Pressure Indication Calibration of Cement Fineness Negative Pressure Sieve Analyzer (8)

1 Scope (1)

2 Reference documents (1)

3 Terms and measurement units (1)

3.1 Term (1)

3.2 Unit of measurement(1)

4 Overview (1)

5 Measurement characteristics (2)

5.1 Measuring range (2)

5.2 Indication error (2)

5.3 Return error (2)

5.4 Insulation resistance (2)

5.5 Noise (2)

5.6 Speed (2)

6 Calibration conditions (2)

6.1 Environmental conditions (2)

6.2 Measurement standards and other equipment (2)

7 Calibration items and calibration methods (2)

7.1 Appearance and functional inspection (2)

7.2 Indication error (3)

7.3 Return error (3)

7.4 Insulation resistance (3)

7.5 Noise(3)

7.6 Speed(4)

8 Calibration result expression (4)

8.1 Calibration data processing (4)

8.2 Calibration certificate (4)

8.3 Evaluation of calibration uncertainty (4)

9 Re-calibration interval (4)

Appendix A Original record of calibration of cement fineness negative pressure sieve analyzer (recommended style) (5)

Appendix B Inside page of calibration certificate (recommended style) (6)

Appendix C Example of Uncertainty Evaluation of Pressure Indication Calibration of Cement Fineness Negative Pressure Sieve Analyzer (8)

Introduction

JJF 1001-2011 "General Metrology Terms and Definitions", JJF 1059.1-2012 "Measuring Uncertainty Evaluation and Representation", JJF 1071-2010 "Rules for the Compilation of National Metrology and Calibration Specifications" constitute support for the formulation of this calibration specification Basic documents.

Also refer to JJG52-2013 "Elastic element type general pressure gauge, pressure vacuum gauge and vacuum gauge", GB/T 1345-2005 "Cement Fineness Inspection Method Sieve Analysis Method", GB/T 5329-2003 "Test Sieve and Sieve Test Terminology" technical document.

This specification is released for the first time.

Calibration specification for cement fineness negative pressure sieve analyzer

1 Scope

This specification applies to the calibration of the non-test sieve part of the cement fineness negative pressure sieve analyzer (hereinafter referred to as the sieve analyzer).

2 Reference documents this specification refers to the following documents.

JJG52-2013 elastic element type general pressure gauge, pressure vacuum gauge and vacuum gauge GB/T 1345-2005 Cement fineness inspection method sieve analysis method GB/T 5329-2003 Test sieve and sieving test terminology for dated reference documents, only the dated version applies to this specification; for undated references the latest version (including all amendments) is applicable to this specification.

3 Terms and units of measurement

3.1 Term

The following terms and definitions defined in GB/T 1345-2005 and GB/T 5329-2003 apply to this code.

3.1.1 Sieving

The process of separating different particles according to size with one or more sieves.

[GB/T 5329-2003, Terms and Definitions 2.3.1]

3.1.2 Test sieve A sieve that meets the technical requirements of the test sieve standard and is used for particle size analysis by sieving method.

[GB/T 5329-2003, Terms and Definitions 2.2.2]

3.1.3 Vacuumsieving

Using a negative pressure sieve analyzer, the constant air flow generated by the negative pressure source will make the cement in the test sieve within the specified sieve analysis time Reach the screening.

[GB/T 1345-2005, Terms and Definitions 4.1]

3.2 Unit of measurement the legal measurement unit used for the pressure parameter of the sieve analyzer is Pa (Pascal), or its decimal multiple unit.

4 overview

The sieve analyzer is an industry-specific instrument with metrological performance for sieve analysis of cement fineness.

The sieve analyzer is composed of a sieve seat, a test sieve, a negative pressure source and a dust suction unit. The sieve seat is composed of an air nozzle, a negative pressure gauge, and a time it is composed of a controller, a motor and a housing.

The sieve analyzer adopts the negative pressure sieve analysis method. Its working principle is to use airflow as the motive medium for sieving.

The industrial vacuum cleaner keeps the entire system in the specified negative pressure state, and the powder material to be tested in the screen is in the rotating air nozzle the ejected air flow becomes a fluid under the action of the air flow, and moves with the air flow. The material with a particle diameter smaller than the screen aperture is caused by the air flow.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 11 pages — is available in the English PDF.

How to Download JJF 1827-2020

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Fast delivery

    After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
11 pages
Fast delivery
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

JJF 1827-2020

$210.00