JJF 1825-2020Calibration Specification for McFarland Bacterial Turbidity Analyzers (English PDF)
麦氏细菌浊度分析仪校准规范
This is a limited preview
Buy now to download the full PDF (9 pages)
Need quotation for your management?
Get a formal quotation for JJF 1825-2020 in 30 minutes.
Issued by
State Administration for Market Regulation
Level / Type
National · Mandatory
Issue date
January 1, 2020
Implementation date
April 17, 2020
Scope
JJF 1825-2020 is the English-translated version of 麦氏细菌浊度分析仪校准规范.
JJF 1825-2020 is the Chinese standard "Calibration Specification for McFarland Bacterial Turbidity Analyzers".
Found what you need?
Document preview — JJF 1825-2020
National Standard of the People's Republic of China
- ICS
- 17.180
Contents
- Introduction (II)
- 1 Scope (1)
- 2 Terms and units of measurement (1)
- 2.1 McNeil Turbidimetry (1)
- 2.2 Meyer's unit (1)
- 3 Overview (1)
- 4 Measurement characteristics (1)
- 4.1 Indication stability (1)
- 4.2 Repeatability (1)
- 4.3 Indication error (1)
- 5 Calibration conditions (1)
- 5.1 Environmental conditions (1)
- 5.2 Reference Standards for Calibration (1)
- 6 Calibration items and calibration methods (1)
- 6.1 Indication stability (1)
- 6.2 Repeatability (2)
- 6.3 Indication error (2)
- 7 Expression of calibration results (2)
- 8 Recalibration time interval (3)
- Appendix A Examples of Uncertainty Evaluation of Indication Error Measurement Results (4)
- Appendix B. Reference Format for Original Calibration Records (6)
- Appendix C Calibration Certificate (Inner Page) Reference Format (8)
1 Scope (1)
2 Terms and units of measurement (1)
2.1 McNeil Turbidimetry (1)
2.2 Meyer's unit (1)
3 Overview (1)
4 Measurement characteristics (1)
4.1 Indication stability (1)
4.2 Repeatability (1)
4.3 Indication error (1)
5 Calibration conditions (1)
5.1 Environmental conditions (1)
5.2 Reference Standards for Calibration (1)
6 Calibration items and calibration methods (1)
6.1 Indication stability (1)
6.2 Repeatability (2)
6.3 Indication error (2)
7 Expression of calibration results (2)
8 Recalibration time interval (3)
Appendix A Examples of Uncertainty Evaluation of Indication Error Measurement Results (4)
Appendix B. Reference Format for Original Calibration Records (6)
Appendix C Calibration Certificate (Inner Page) Reference Format (8)
Introduction
In drafting this specification, reference was made to JJG880-2006 "Turbidity Meter", JJF 1059.1-2012 "Measurement Uncertainty "Assessment and Representation", prepared in accordance with the requirements of JJF 1071-2010 "Rules for Compiling National Measurement and Calibration Specifications".
This specification is the first release.
Calibration Specification of McBee Turbidity Analyzer
1 Scope
This specification applies to the measurement performance of Bacterial Turbidity Analyzer (BacterialTurbidityAnalyzer) calibration.
2 Terminology and units of measurement
2.1 McFarlandmethod
The method of estimating the number of bacteria by measuring the light transmission (turbidity value) of the bacterial suspension, the concentration of the bacterial suspension is Within a certain range, it is inversely proportional to the light transmittance and directly proportional to the optical density.
2.2 McFarlandunit
The unit of bacterial turbidity measured according to the McNeil turbidimetry is MCF.
3 Overview
The McNair bacterial turbidity analyzer (hereinafter referred to as the instrument) is a method for detecting the scattered light of microorganisms in suspension an instrument that reflects the number of microorganisms. The principle is that the greater the content of microorganisms in the suspension, the less light is transmitted through the suspension, the more light is scattered. It is mainly used for bacterial turbidity in the fields of drug sensitivity evaluation, microbial fermentation and microbial detection Detection.
4 Metering characteristics
4.1 Indication stability
4.2 Repeatability
4.3 Indication error
5 Calibration conditions
5.1 Environmental conditions the operating temperature does not exceed 30 ° C, and the relative humidity ranges from 40% to 80%. During the measurement, the ring should be measured and recorded.
Environment temperature and humidity.
5.2 Standard materials for calibration Bacterial turbidity certified reference materials should be used during calibration.
0.5MCF, 1.0MCF, 2.0MCF, 3.0MCF, 4.0MCF), relative expansion uncertainty <=10% (k = 2).
6 Calibration items and calibration methods
6.1 Indication stability According to the requirements of the instrument manual, if zero adjustment is required, use a bacterial turbidity standard material with a nominal value of 0.0MCF
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 9 pages — is available in the English PDF.
How to Download JJF 1825-2020
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Fast delivery
After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
JJF 2425-2026 — Calibration specification for carbon dioxide incubators
JJF 1183-2025 — Calibration Specification for Temperature Transmitters
JJF 1282-2025 — Calibration Specification for Time Delay Relays
JJF 1825-2020
$225.00