JJF 1820-2020Calibration Specification for Milk Quantitative Composition Analyzers (English PDF)
乳品成分分析仪校准规范
This is a limited preview
Buy now to download the full PDF (10 pages)
Need quotation for your management?
Get a formal quotation for JJF 1820-2020 in 30 minutes.
Issued by
State Administration for Market Regulation
Level / Type
National · Mandatory
Issue date
January 1, 2020
Implementation date
April 17, 2020
Scope
JJF 1820-2020 is the English-translated version of 乳品成分分析仪校准规范.
JJF 1820-2020 is the Chinese standard "Calibration Specification for Milk Quantitative Composition Analyzers".
Found what you need?
Document preview — JJF 1820-2020
National Standard of the People's Republic of China
- ICS
- 17.020
Contents
- Introduction (II)
- 1 Scope (1)
- 2 References (1)
- 3 Overview (1)
- 4 Measurement characteristics (1)
- 5 Calibration conditions (1)
- 5.1 Environmental conditions (1)
- 5.2 Calibration reference materials and other equipment (1)
- 6 Calibration items and calibration methods (2)
- 6.1 Preparation before calibration (2)
- 6.2 Calibration method (2)
- 7 Expression of calibration results (3)
- 8 Recalibration time interval (3)
- Appendix A Series Standard Solution Preparation and Linear Error Calculation Example (4)
- Appendix B Calibration Record Format (6)
- Appendix C Internal Format of Calibration Certificate (8)
- Appendix D Example of Uncertainty Evaluation of Indication Error (9)
1 Scope (1)
2 References (1)
3 Overview (1)
4 Measurement characteristics (1)
5 Calibration conditions (1)
5.1 Environmental conditions (1)
5.2 Calibration reference materials and other equipment (1)
6 Calibration items and calibration methods (2)
6.1 Preparation before calibration (2)
6.2 Calibration method (2)
7 Expression of calibration results (3)
8 Recalibration time interval (3)
Appendix A Series Standard Solution Preparation and Linear Error Calculation Example (4)
Appendix B Calibration Record Format (6)
Appendix C Internal Format of Calibration Certificate (8)
Appendix D Example of Uncertainty Evaluation of Indication Error (9)
Introduction
This specification is based on JJF 1071-2010 "Rules for Compiling National Measurement and Calibration Specifications", JJF 1059.1-2012 Compilation of "Measurement Uncertainty Evaluation and Representation" and JJF 1265-2010 "Biometric Terms and Definitions". Linearity error the calibration methods and technical indicators of the measurement repeatability and the use of ISO 9622.:2013/IDF141..2013 "Milk and Liquid Dairy Products Infrared Spectroscopy Application Guide (Milkandliquidmilkproducts-Guidelinesforthe applicationofmid-infraredspectrometry) section 6.1.4 and section 11.1.
This specification is the first release.
Calibration Specification for Dairy Ingredient Analyzer
1 Scope
This specification is applicable to dairy ingredient analyzers (hereinafter referred to as analyzers) based on the principle of mid-infrared spectral absorption calibration.
2 Reference documents this specification refers to the following documents.
JJF 1071-2010 Compilation Rules for National Measurement and Calibration Specifications GB/T 6682-2008 Analytical laboratory water specifications and test methods for dated reference documents, only the dated version applies to this specification; for those without date references the latest version (including all amendments) is applicable to this specification.
3 Overview
The analyzer is based on the principle of spectral absorption to quickly measure the content of protein, fat, lactose and other components in liquid milk instrument. The analyzer determines the absorbance of liquid milk at a specific wavelength in the mid-infrared the built-in absorbance-content curve equation calculates the protein, fat, lactose and other contents in dairy products. Analyzer Pass it is often composed of light source, wavelength controller, sample cell (including sampler), detector, signal conversion/output, etc.
4 Measurement characteristics Analyzer calibration items and technical index requirements are shown in Table 1.
Table 1 Calibration items and technical index requirements
Calibration items
Technical index
Fat protein lactose
Indication error/(g/100g) ± 0.30 ± 0.30 ± 0.30 Measurement repeatability/(g/100g) 0.04 0.04 0.04 Linearity error /% 2 2 2 Note. The above technical indicators are not used to determine eligibility, for reference only.
5 Calibration conditions
5.1 Environmental conditions According to the environmental conditions specified in the instrument manual, the ambient temperature, relative humidity, etc. should be recorded during the calibration process data.
5.2 Calibration reference materials and other equipment
5.2.1 Dairy standard substance. at least contains protein, fat, lactose (or total sugar) content, relative expansion is not correct
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 10 pages — is available in the English PDF.
How to Download JJF 1820-2020
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Fast delivery
After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
JJF 2425-2026 — Calibration specification for carbon dioxide incubators
JJF 1183-2025 — Calibration Specification for Temperature Transmitters
JJF 1282-2025 — Calibration Specification for Time Delay Relays