JJF 1818-2020Calibration Specification for Calibration Device of Raman Spectrometers (English PDF)
拉曼光谱仪校准装置校准规范
This is a limited preview
Buy now to download the full PDF (10 pages)
Need quotation for your management?
Get a formal quotation for JJF 1818-2020 in 30 minutes.
Issued by
State Administration for Market Regulation
Level / Type
National · Mandatory
Issue date
January 1, 2020
Implementation date
April 17, 2020
Scope
JJF 1818-2020 is the English-translated version of 拉曼光谱仪校准装置校准规范.
JJF 1818-2020 is the Chinese standard "Calibration Specification for Calibration Device of Raman Spectrometers".
Found what you need?
Document preview — JJF 1818-2020
National Standard of the People's Republic of China
- ICS
- 17.180
Contents
- Introduction (II)
- 1 Scope (1)
- 2 Reference documents (1)
- 3 Terms and measurement units (1)
- 4 Overview (1)
- 5 Measurement characteristics (1)
- 5.1 Raman frequency shift of standard silicon wafer (1)
- 5.2 Relative strength of standard glass (1)
- 6 Calibration conditions (2)
- 6.1 Environmental conditions (2)
- 6.2 Measurement standards and other equipment (2)
- 7 Calibration items and calibration methods (2)
- 7.1 Visual inspection (2)
- 7.2 Raman frequency shift (2)
- 7.3 Relative strength (2)
- 8 Calibration result expression (3)
- 8.1 Calibration record (3)
- 8.2 Processing of calibration results (3)
- 9 Recheck interval (3)
- Appendix A Raman spectrometer calibration device calibration original record (recommended) format style (4)
- Appendix B. Internal page of calibration certificate (recommended) format (5)
- Appendix C Evaluation Example of Measurement Uncertainty (7)
1 Scope (1)
2 Reference documents (1)
3 Terms and measurement units (1)
4 Overview (1)
5 Measurement characteristics (1)
5.1 Raman frequency shift of standard silicon wafer (1)
5.2 Relative strength of standard glass (1)
6 Calibration conditions (2)
6.1 Environmental conditions (2)
6.2 Measurement standards and other equipment (2)
7 Calibration items and calibration methods (2)
7.1 Visual inspection (2)
7.2 Raman frequency shift (2)
7.3 Relative strength (2)
8 Calibration result expression (3)
8.1 Calibration record (3)
8.2 Processing of calibration results (3)
9 Recheck interval (3)
Appendix A Raman spectrometer calibration device calibration original record (recommended) format style (4)
Appendix B. Internal page of calibration certificate (recommended) format (5)
Appendix C Evaluation Example of Measurement Uncertainty (7)
Introduction
The compilation of this specification is based on JJF 1071-2010 "Rules for the Compilation of National Metrology and Calibration Specifications", JJF 1001-2011 "General Metrology Terms and Definitions" and JJF 1059.1-2012 "Evaluation and Expression of Measurement Uncertainty" as the basis and basis According to data, and mainly refer to JJF 1544-2015 "Raman Spectrometer Calibration Specification" and ASTME1683-02 (2014) "Standard Practice for Testing the Scanning Raman Spectrometer" (Standard Practice for Testing the PerformanceofScanningRamanSpectrometers).
This specification is released for the first time.
Calibration specification for Raman spectrometer calibration device
1 Scope
This specification applies to the calibration of Raman spectrometer calibration devices.
2 Reference documents this specification refers to the following documents.
JJF 1544-2015 Raman Spectrometer Calibration Specification ASTME1683-02 (2014) Scanning Raman Spectrometer Performance Test Standard Operation Specification (Standard PracticeforTestingthePerformanceofScanningRamanSpectrometers) for dated reference documents, only the dated version applies to this specification; for undated references the latest version (including all amendments) is applicable to this specification.
3 Terms and units of measurement the terms and definitions specified in JJF 1544-2015 "Raman Spectrometer Calibration Specification" and the following terms and definitions apply to this specification.
3.1 Raman shift Ramanshift the frequency change of Raman scattered light relative to the excitation light, referred to as "frequency shift", in cm-1.
3.2 relative intensity relative intensity the normalized result of Raman scattering intensity relative to the maximum intensity value.
4 overview
The Raman spectrometer calibration device is composed of standard silicon wafers, standard glass and atomic line lamps.
The Raman peak of the standard silicon wafer near 520cm-1 is used to calibrate the frequency shift indication error of the Raman spectrometer. standard Glass is a glass doped with metal oxides, which can generate a stable and continuous spectral signal under laser excitation for calibration the relative intensity of the Raman spectrometer. The atomic spectrum emitted by the atomic spectrum lamp is a natural reference and is used to calibrate the Raman spectrometer Spectral resolution, frequency shift repeatability and other parameters.
5 Metrological characteristics
5.1 Standard silicon wafer Raman frequency shift the expanded uncertainty of the center frequency shift of the Raman peak near 520cm-1 is U<=0.5cm-1 (k=2).
5.2 Relative strength of standard glass the expanded uncertainty of relative strength U<=5% (k=2).
Note. The above indicators are not used as eligibility criteria, only for reference.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 10 pages — is available in the English PDF.
How to Download JJF 1818-2020
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Fast delivery
After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.