JJF 1817-2020Calibration Specification for Nucleic Acids Analyzers (English PDF)
核酸分析仪校准规范
This is a limited preview
Buy now to download the full PDF (10 pages)
Need quotation for your management?
Get a formal quotation for JJF 1817-2020 in 30 minutes.
Issued by
State Administration for Market Regulation
Level / Type
National · Mandatory
Issue date
January 1, 2020
Implementation date
April 17, 2020
Scope
JJF 1817-2020 is the English-translated version of 核酸分析仪校准规范.
JJF 1817-2020 is the Chinese standard "Calibration Specification for Nucleic Acids Analyzers".
Found what you need?
Document preview — JJF 1817-2020
National Standard of the People's Republic of China
- ICS
- 17.020
Contents
- Introduction (II)
- 1 Scope (1)
- 2 References (1)
- 3 Terms and units of measurement (1)
- 4 Overview (1)
- 5 Metrological characteristics (1)
- 5.1 Indication error (1)
- 5.2 Repeatability (1)
- 5.3 Fragment concentration linearity (2)
- 6 Calibration conditions (2)
- 6.1 Environmental conditions (2)
- 6.2 Calibration reference materials and calibration equipment (2)
- 7 Calibration items and calibration methods (2)
- 7.1 Indication error (2)
- 7.2 Repeatability (3)
- 7.3 Concentration linearity (3)
- 8 Expression of calibration results (4)
- 9 Recalibration time interval (4)
- Appendix A. Preparation and use of calibration reagents and solutions (5)
- Appendix B. Reference Format for Original Calibration Records (6)
- Appendix C. Reference Format of Internal Page of Calibration Certificate (7)
- Appendix D Example of uncertainty assessment of concentration indication error (8)
1 Scope (1)
2 References (1)
3 Terms and units of measurement (1)
4 Overview (1)
5 Metrological characteristics (1)
5.1 Indication error (1)
5.2 Repeatability (1)
5.3 Fragment concentration linearity (2)
6 Calibration conditions (2)
6.1 Environmental conditions (2)
6.2 Calibration reference materials and calibration equipment (2)
7 Calibration items and calibration methods (2)
7.1 Indication error (2)
7.2 Repeatability (3)
7.3 Concentration linearity (3)
8 Expression of calibration results (4)
9 Recalibration time interval (4)
Appendix A. Preparation and use of calibration reagents and solutions (5)
Appendix B. Reference Format for Original Calibration Records (6)
Appendix C. Reference Format of Internal Page of Calibration Certificate (7)
Appendix D Example of uncertainty assessment of concentration indication error (8)
Introduction
The preparation of this specification is based on the test of the main technical parameters of the nucleic acid analyzer, based on JJF 1071-2010 the provisions of "National Rules for the Preparation of Metrology Calibration", JJF 1059.1-2012 "Measurement Uncertainty Evaluation and Expression" Make it.
This specification is the first release.
Calibration Specification for Nucleic Acid Analyzer
1 Scope
This specification is applicable to nucleic acid analyzers that analyze the length and concentration of nucleic acid fragments based on the principle of gel electrophoresis Calibration, the length range of applicable nucleic acid fragments is (100 ~ 1000) bp, for nuclear the calibration of the acid analyzer can be performed with reference to this specification. This specification does not apply to plate electrophoresis and genetic analyzers calibration.
2 Reference documents this specification refers to the following documents.
JJF 1265-2010 Biometric Terms and Definitions for dated reference documents, only the dated version applies to this specification; for those without date references the latest version (including all amendments) is applicable to this specification.
3 Terms and units of measurement
3.1 Fragment length
Represents the size of a nucleic acid fragment in units of nucleotides (nt) or base pairs (bp).
3.2 basepair (bp) basepair Paired bases between two strands in nucleic acids. Such as adenine-thymine (AT) pair, adenine-uracil (A-U), guanine-cytosine (GC) pair, guanine-uracil (GU) pair, etc. The number of base pairs characterizes DNA or the length of double-stranded RNA.
[JJF 1265-2010,4.41]
4 Overview
The nucleic acid analyzer (hereinafter referred to as the analyzer) is based on the principle of gel electrophoresis technology and converts double-stranded nucleic acids of different sizes.
The fragments are separated.In the presence of fluorescent dyes, the fluorescent dyes are embedded in the double-stranded nucleic acid to emit fluorescence.
Signal detection and analysis equipment can be qualitative and quantitative according to the electrophoresis time and fluorescence signal value of each nucleic acid fragment analysis. The analyzer is usually composed of a sampler, capillary/microchip, fluorescence detection optical components, microcircuit control components, Computer and application software, can be used for single and multiple PCR fragments, restriction enzyme digested DNA, etc.
Analysis of fragment length and concentration.
5 Metrological characteristics
5.1 Indication error Fragment length indication error and fragment concentration indication error.
5.2 Repeatability
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 10 pages — is available in the English PDF.
How to Download JJF 1817-2020
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Fast delivery
After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
JJF 2425-2026 — Calibration specification for carbon dioxide incubators
JJF 1183-2025 — Calibration Specification for Temperature Transmitters
JJF 1282-2025 — Calibration Specification for Time Delay Relays
JJF 1817-2020
$265.00