Valid

JJF 1816-2020Calibration Specification for Raw-Milk Freezing Point Testers (English PDF)

生乳冰点仪校准规范

Preview PDF

This is a limited preview

Buy now to download the full PDF (8 pages)

Need quotation for your management?

Get a formal quotation for JJF 1816-2020 in 30 minutes.

Issued by

State Administration for Market Regulation

Level / Type

National · Mandatory

Issue date

January 1, 2020

Implementation date

April 17, 2020

Scope

JJF 1816-2020 is the English-translated version of 生乳冰点仪校准规范.

JJF 1816-2020 is the Chinese standard "Calibration Specification for Raw-Milk Freezing Point Testers".

Found what you need?

Document preview — JJF 1816-2020

National Standard of the People's Republic of China

ICS
17.200

Contents

  • Introduction (II)
  • 1 Scope (1)
  • 2 References (1)
  • 3 Terms and units of measurement (1)
  • 4 Overview (1)
  • 5 Metrological characteristics (1)
  • 6 Calibration conditions (2)
  • 6.1 Environmental conditions (2)
  • 6.2 Reference materials and calibration equipment (2)
  • 7 Calibration items and calibration methods (2)
  • 7.1 Indication error (2)
  • 7.2 Repeatability (2)
  • 7.3 Stability (2)
  • 8 Expression of calibration results (3)
  • 9 Recalibration time interval (3)
  • Appendix A Example of Evaluation of Uncertainty in Indication Error of Freezing Point (4)
  • Appendix B. Raw Record Format of Raw Milk Freezing Point Calibration (for reference) (6)
  • Appendix C Format of Calibration Certificate (Inner Page) (For Reference) (7)

1 Scope (1)

2 References (1)

3 Terms and units of measurement (1)

4 Overview (1)

5 Metrological characteristics (1)

6 Calibration conditions (2)

6.1 Environmental conditions (2)

6.2 Reference materials and calibration equipment (2)

7 Calibration items and calibration methods (2)

7.1 Indication error (2)

7.2 Repeatability (2)

7.3 Stability (2)

8 Expression of calibration results (3)

9 Recalibration time interval (3)

Appendix A Example of Evaluation of Uncertainty in Indication Error of Freezing Point (4)

Appendix B. Raw Record Format of Raw Milk Freezing Point Calibration (for reference) (6)

Appendix C Format of Calibration Certificate (Inner Page) (For Reference) (7)

Introduction

This specification is based on JJF 1071-2010 "Rules for Compiling National Measurement and Calibration Specifications", JJF 1001-2011 "General Measurement Terms and Definitions "and JJF 1059.1-2012" Measurement Uncertainty Evaluation and Expression "as the basic series of specifications Make it.

This specification refers to ISO 5764/IDF108..2009 "Determination of the freezing point of milk" Thermistor freezing point method (Benchmark method) "[Milk-Determinationoffreezingpoint-Thermistorcryoscopemethod (Referencemethod)], GB 5413.38-2010 "Determination of Freezing Point of Raw Milk of National Food Safety Standard" Technical content.

This specification is the first release.

Calibration specification for raw milk freezing point instrument

1 Scope

This specification is applicable to the calibration of raw milk freezing point instrument based on thermistor for measuring freezing point temperature.

2 Reference documents this specification refers to the following documents.

GB 5413.38-2010 National Food Safety Standard Determination of Freezing Point of Raw Milk ISO 5764/IDF108..2009 Determination of freezing point of milk Thermistor freezing point method (reference method) [Milk-Determinationoffreezingpoint-Thermistorcryoscope method (Reference method)] for dated reference documents, only the dated version applies to this specification; for those without date references the latest version (including all amendments) is applicable to this specification.

3 Terms and units of measurement

3.1 FreezingPointDepression, FPD Freezing point of raw milk. The unit is expressed in millidegrees Celsius (m ° C).

4 Overview

The working principle of the raw milk freezing point instrument (hereinafter referred to as the freezing point instrument) is to directly measure the raw temperature through the thermistor inside the instrument.

Milk freezing point. When measuring, put a certain amount of milk sample in the sample tube, put it in a cold trap, and immerse the temperature probe into the milk sample to be measured in the center, the freezing point instrument begins to cool. When the milk sample to be tested is cooled to -3 °C, the freezing point instrument performs seeding Continue to release heat to raise the temperature of the milk sample to the highest point, and keep the temperature constant for a short time, which is the same as the freezing point temperature.

Taiwan, this temperature is the freezing point of the milk sample.

The freezing point instrument is usually composed of refrigeration system, temperature measurement system, temperature control system, data processing system and display system.

composition.

5 Metrological characteristics the main measurement characteristics of the freezing point meter are shown in Table 1.

Table 1 Main measurement characteristics of freezing point instrument

Serial number characteristic parameter requirements

1 Indication error MPE. ± 5m °C

2 Repeatability <=0.5%

3 Stability <=6m °C

Note. The above indicators are not used to determine eligibility, for reference only.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 8 pages — is available in the English PDF.

How to Download JJF 1816-2020

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Fast delivery

    After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
8 pages
Fast delivery
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

JJF 1816-2020

$210.00