JJF 1815-2020Calibration Specification for Class II Biosafety Cabinets (English PDF)
Ⅱ级生物安全柜校准规范
This is a limited preview
Buy now to download the full PDF (35 pages)
Need quotation for your management?
Get a formal quotation for JJF 1815-2020 in 30 minutes.
Issued by
State Administration for Market Regulation
Level / Type
National · Mandatory
Issue date
January 1, 2020
Implementation date
April 17, 2020
Scope
JJF 1815-2020 is the English-translated version of Ⅱ级生物安全柜校准规范.
JJF 1815-2020 is the Chinese standard "Calibration Specification for Class II Biosafety Cabinets".
Found what you need?
Document preview — JJF 1815-2020
National Standard of the People's Republic of China
- ICS
- 17.020
Contents
- Introduction (III)
- 1 Scope (1)
- 2 References (1)
- 3 Terms and units of measurement (1)
- 3.1 Biological media (1)
- 3.2 Biological hazards (1)
- 3.3 Cross-contamination (1)
- 3.4 Product protection (1)
- 3.5 Airflow (1)
- 3.6 Nominal width of biological safety cabinet (2)
- 3.7 Biological safety level (2)
- 3.8 Biological safety cabinet (3)
- 3.9 Nominal value of flow rate (3)
- 3.10 Umbrella cover exhaust connection (3)
- 3.11 Direct exhaust connection (3)
- 3.12 High efficiency filter (3)
- 3.13 Polydisperse aerosol (3)
- 3.14 Work area (4)
- 3.15 Workbench (4)
- 3.16 Front window (4)
- 3.17 Height of front window operating port (4)
- 3.18 Protection factor (4)
- 4 Overview (4)
- 5 Metrological characteristics (5)
- 6 Calibration conditions (6)
- 6.1 Environmental conditions (6)
- 6.2 Standards and supporting equipment for calibration (6)
- 7 Calibration items and calibration methods (8)
- 7.1 Visual inspection (8)
- 7.2 Downflow velocity (8)
- 7.3 Inflow velocity (9)
- 7.4 Airflow mode (11)
- 7.5 Cleanliness (12)
- 7.6 Illumination (12)
- 7.7 Noise (13)
- 7.8 High efficiency/ultra high efficiency filter leak detection (14)
- 7.9 Protection of personnel, products and cross-contamination (16)
- 8 Expression of calibration results (22)
- 9 Recalibration time interval (22)
- Appendix A Potassium Iodide Method (23)
- Appendix B Calibration Original Record Format (28)
- Appendix C Calibration Certificate (Inner Page) Format (32)
- Appendix D Example of Measurement Uncertainty Evaluation of Calibration Results of Class II Biological Safety Cabinet (33)
1 Scope (1)
2 References (1)
3 Terms and units of measurement (1)
3.1 Biological media (1)
3.2 Biological hazards (1)
3.3 Cross-contamination (1)
3.4 Product protection (1)
3.5 Airflow (1)
3.6 Nominal width of biological safety cabinet (2)
3.7 Biological safety level (2)
3.8 Biological safety cabinet (3)
3.9 Nominal value of flow rate (3)
3.10 Umbrella cover exhaust connection (3)
3.11 Direct exhaust connection (3)
3.12 High efficiency filter (3)
3.13 Polydisperse aerosol (3)
3.14 Work area (4)
3.15 Workbench (4)
3.16 Front window (4)
3.17 Height of front window operating port (4)
3.18 Protection factor (4)
4 Overview (4)
5 Metrological characteristics (5)
6 Calibration conditions (6)
6.1 Environmental conditions (6)
6.2 Standards and supporting equipment for calibration (6)
7 Calibration items and calibration methods (8)
7.1 Visual inspection (8)
7.2 Downflow velocity (8)
7.3 Inflow velocity (9)
7.4 Airflow mode (11)
7.5 Cleanliness (12)
7.6 Illumination (12)
7.7 Noise (13)
7.8 High efficiency/ultra high efficiency filter leak detection (14)
7.9 Protection of personnel, products and cross-contamination (16)
8 Expression of calibration results (22)
9 Recalibration time interval (22)
Appendix A Potassium Iodide Method (23)
Appendix B Calibration Original Record Format (28)
Appendix C Calibration Certificate (Inner Page) Format (32)
Appendix D Example of Measurement Uncertainty Evaluation of Calibration Results of Class II Biological Safety Cabinet (33)
Introduction
The preparation of this specification is based on JJF 1001-2011 "General Measurement Terms and Definitions", JJF 1071-2010 "Country "Measurement Calibration Rules" and "JJF 1059.1-2012" Measurement Uncertainty Evaluation and Expression "as the basis and basis according to. The calibration method and measurement characteristics are mainly referred to BSEN12469.:2000 "Biotechnology Microbiological Safety Cabinet Performance standards "(Biotechnology-Performance criteria for microbiological safetycabinets), NSF/ANSI49-2018 "Biosafety cabinet design, structure, performance and on-site certification" (BiosafetyCabin-etry-Design, Construction, Performance, and Field Certification), ISO 14644-1.
2015 `` Clean Room and Related Controlled Environment Part 1. Classification of Air Cleanliness Based on Particle Concentration '' (Clean-roomsandassociatedcontroledenvironments Part 1. Classificationofaircleanliness byparticleconcentration), BS5726-3.:1992 "Microbiological safety cabinet specifications Part 3. After installation Performance Specification (Microbiologicalsafetycabinets Part 3. Specification for performance after instalation), WS233-2017 "General Guidelines for Biosafety of Pathogenic Microbiology Laboratories", YY0569-2011 "Class II Biosafety Cabinet".
This specification is the first release.
Calibration standard for Class II biological safety cabinet
1 Scope
This specification applies to the calibration of Class II biological safety cabinets, and the calibration of the same principle parts of Class I and III biological safety cabinet can refer to the implementation of this specification.
2 Reference documents this specification refers to the following documents.
BSEN12469.:2000 Performance Standards for Biotechnology Microbiological Safety Cabinet (Biotechnology-Per-formancecriteriaformicrobiologicalsafetycabinets) NSF/ANSI49-2018 biological safety cabinet design, structure, performance and on-site certification (Biosafety Cabinetry. Design, Construction, Performance, andFieldCertification) ISO 14644-1.:2015 Clean rooms and related controlled environments Part 1. Clean air according to particle concentration Clarity classification (CleanroomsandassociatedcontroledenvironmentsPart 1. Classification ofaircleanlinessbyparticleconcentration) BS5726-3.:1992 Specification for microbiological safety cabinets. Part 3. Performance specifications after installation (Microbiological safetycabinets Part 3. Specificationforperformanceafterinstalation) WS233-2017 General Guidelines for Biosecurity in Pathogenic Microbiology Laboratories for dated reference documents, only the dated version applies to this specification; for those without date references the latest version (including all amendments) is applicable to this specification.
3 Terms and units of measurement as defined in BSEN12469.:2000, NSF/ANSI49-2018 and ISO 14644-1.:2015 and below Terms and definitions apply to this specification.
3.1 Biological agents biological agents [NSF/ANSI49-2018] all microorganisms and biologically active substances.
3.2 Biohazard [NSF/ANSI49-2018] Direct or potential hazards caused by biological media.
3.3 Crosscontamination [BSEN12469-2000] Substances outside the target accidentally enter the target.
3.4 Product protection [BSEN12469-2000] the biological safety cabinet prevents contaminants from outside air from spreading into the working area of the safety cabinet through the front window operation port.
3.5 Airflow
3.5.1 Downflow velocity downflow velocity [NSF/ANSI49-2018] the airflow velocity from the vertical above the biological safety cabinet filtered by the high-efficiency filter to the work area provides production
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 35 pages — is available in the English PDF.
How to Download JJF 1815-2020
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Fast delivery
After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
JJF 2425-2026 — Calibration specification for carbon dioxide incubators
JJF 1183-2025 — Calibration Specification for Temperature Transmitters
JJF 1282-2025 — Calibration Specification for Time Delay Relays
JJF 1815-2020