JJF 1810-2020 is the English-translated version of 医用吸引器校准规范.
JJF 1810-2020 is the Chinese standard "Calibration Specification for Medical Suction Equipment".
Found what you need?
Document preview — JJF 1810-2020
National Standard of the People's Republic of China
- ICS
- 17.100
Contents
- Introduction (II)
- 1 Scope (1)
- 2 Reference documents (1)
- 3 Terms and measurement units (1)
- 3.1 Term (1)
- 3.2 Unit of measurement (2)
- 4 Overview (2)
- 5 Measurement characteristics (2)
- 5.1 Negative pressure indication error (2)
- 5.2 Negative pressure return error (2)
- 5.3 Set point deviation (2)
- 5.4 Noise(2)
- 5.5 Insulation resistance (3)
- 6 Calibration conditions (3)
- 6.1 Environmental conditions (3)
- 6.2 Measurement standards and other equipment (3)
- 7 Calibration items and calibration methods (3)
- 7.1 Appearance and functional inspection (3)
- 7.2 Negative pressure indication error (3)
- 7.3 Negative pressure return error (4)
- 7.4 Set point deviation (4)
- 7.5 Noise(4)
- 7.6 Insulation resistance (4)
- 8 Calibration result expression (4)
- 9 Recalibration interval (5)
- Appendix A Calibration Record Format of Medical Suction Apparatus (6)
- Appendix B. Calibration result page format of calibration certificate for medical suction apparatus (7)
- Appendix C Example of Uncertainty Evaluation of the Error of the Negative Pressure of the Medical Suction Apparatus (8)
1 Scope (1)
2 Reference documents (1)
3 Terms and measurement units (1)
3.1 Term (1)
3.2 Unit of measurement (2)
4 Overview (2)
5 Measurement characteristics (2)
5.1 Negative pressure indication error (2)
5.2 Negative pressure return error (2)
5.3 Set point deviation (2)
5.4 Noise(2)
5.5 Insulation resistance (3)
6 Calibration conditions (3)
6.1 Environmental conditions (3)
6.2 Measurement standards and other equipment (3)
7 Calibration items and calibration methods (3)
7.1 Appearance and functional inspection (3)
7.2 Negative pressure indication error (3)
7.3 Negative pressure return error (4)
7.4 Set point deviation (4)
7.5 Noise(4)
7.6 Insulation resistance (4)
8 Calibration result expression (4)
9 Recalibration interval (5)
Appendix A Calibration Record Format of Medical Suction Apparatus (6)
Appendix B. Calibration result page format of calibration certificate for medical suction apparatus (7)
Appendix C Example of Uncertainty Evaluation of the Error of the Negative Pressure of the Medical Suction Apparatus (8)
Introduction
JJF 1001-2011 "General Measurement Terms and Definitions", JJF 1008-2008 "Pressure Measurement Terms and Definitions" ", JJF 1059.1-2012 "Evaluation and Expression of Measurement Uncertainty", JJF 1071-2010 "National Metrology Calibration the Rules for the Compilation of Specifications together constitute a basic series of specifications that support the formulation of this specification.
This specification also refers to JJG52 "Elastic element type general pressure gauge, pressure vacuum gauge and vacuum gauge", YY0636.1-2008 "Medical Suction Equipment Part 1: Safety Requirements for Electric Suction Equipment", YY0636.2-2008 "Medical suction equipment Part 2: Manually driven suction equipment", YY0636.3-2008 "Medical suction equipment Part 3: Suction equipment powered by negative pressure or pressure source" and other technical documents.
This specification is released for the first time.
Calibration Specification for Medical Suction Apparatus
1 Scope
This specification is applicable to the calibration of medical electric suction devices and artificially driven suction devices (hereinafter referred to as suction devices).
2 Reference documents this specification refers to the following documents.
JJG52 elastic element type general pressure gauge, pressure vacuum gauge and vacuum gauge JJF 1008-2008 Pressure measurement terms and definitions YY0636.1-2008 Medical suction equipment Part 1: Safety requirements for electric suction equipment YY0636.2-2008 Medical suction equipment Part 2: Manually driven suction equipment YY0636.3-2008 Medical suction equipment Part 3: Suction equipment powered by negative pressure or pressure source for dated reference documents, only the dated version applies to this specification; for undated references the latest version (including all amendments) is applicable to this specification.
3 Terms and units of measurement
3.1 Term
3.1.1 Attract suction Apply negative pressure to extract liquid and/or solid particles.
[YY0636.1-2008, definition 3.19]
3.1.2 Negative pressure Use atmospheric pressure as a reference point, a pressure less than atmospheric pressure.
[JJF 1008-2008, definition 1.7]
3.1.3 High vacuum
The pressure value is lower than or equal to -60kPa.
3.1.4 Mediumvacuum
The pressure value is higher than -60kPa but lower than -20kPa.
3.1.5 Low negative pressure lowvacuum the pressure value is higher than or equal to -20kPa but lower than 0kPa.
3.1.6 High Flow Suction the flow of free airflow generated by the suction is greater than or equal to 20L/min.
[YY0636.1-2008, definition 3.9]
3.1.7 Low Flow Suction the flow of free air flow generated by suction is less than 20L/min.
[YY0636.1-2008, definition 3.14]
3.1.8 Setpoint deviation
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 11 pages — is available in the English PDF.
How to Download JJF 1810-2020
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Fast delivery
After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
JJF 2425-2026 — Calibration specification for carbon dioxide incubators
JJF 1183-2025 — Calibration Specification for Temperature Transmitters
JJF 1282-2025 — Calibration Specification for Time Delay Relays
JJF 1810-2020
$225.00