JJF 1807-2020Calibration Specification for Total Spectral Radiant Flux Lamps (English PDF)
光谱总辐射通量灯校准规范
This is a limited preview
Buy now to download the full PDF (11 pages)
Need quotation for your management?
Get a formal quotation for JJF 1807-2020 in 30 minutes.
Issued by
State Administration for Market Regulation
Level / Type
National · Mandatory
Issue date
January 1, 2020
Implementation date
April 17, 2020
Scope
JJF 1807-2020 is the English-translated version of 光谱总辐射通量灯校准规范.
JJF 1807-2020 is the Chinese standard "Calibration Specification for Total Spectral Radiant Flux Lamps".
Found what you need?
Document preview — JJF 1807-2020
National Standard of the People's Republic of China
- ICS
- 17.180
Contents
- Introduction (II)
- 1 Scope (1)
- 2 Reference documents (1)
- 3 Term (1)
- 4 Overview (1)
- 5 Measurement characteristics (1)
- 6 Calibration conditions (1)
- 6.1 Environmental conditions (1)
- 6.2 Measurement standards and other equipment (2)
- 7 Calibration items and calibration methods (3)
- 7.1 Calibration items (3)
- 7.2 Calibration method (4)
- 8 Calibration result expression (6)
- 9 Recalibration interval (6)
- Appendix A Reference Format of Internal Page of Calibration Certificate of Spectral Total Radiant Flux Lamp (7)
- Appendix B Example of Uncertainty Evaluation for Calibration of Spectral Total Radiant Flux Lamp (8)
- Appendix C Spectral absorption correction coefficient and calculation method (11)
1 Scope (1)
2 Reference documents (1)
3 Term (1)
4 Overview (1)
5 Measurement characteristics (1)
6 Calibration conditions (1)
6.1 Environmental conditions (1)
6.2 Measurement standards and other equipment (2)
7 Calibration items and calibration methods (3)
7.1 Calibration items (3)
7.2 Calibration method (4)
8 Calibration result expression (6)
9 Recalibration interval (6)
Appendix A Reference Format of Internal Page of Calibration Certificate of Spectral Total Radiant Flux Lamp (7)
Appendix B Example of Uncertainty Evaluation for Calibration of Spectral Total Radiant Flux Lamp (8)
Appendix C Spectral absorption correction coefficient and calculation method (11)
Introduction
JJF 1001-2011 "General Metrology Terms", JJF 1032-2005 "Optical Radiation Metrology Terms and Definitions ", JJF 1059.1-2012 "Evaluation and Expression of Measurement Uncertainty" and JJF 1071-2010 "National Metrology School the "Rules for Compiling Quasi-Specifications" together constitute the basic technical documents for the formulation of this calibration specification.
This specification is released for the first time.
Spectral total radiant flux lamp calibration specification
1 Scope
This specification applies to calibrating total spectral radiation using the relative comparison method in an integrating sphere calibration device with a spectroradiometer Flux lamp, the total radiant flux calibration spectrum range is 350nm~1100nm.
2 Reference documents this specification refers to the following documents.
JJG247 total luminous flux standard incandescent lamp for dated reference documents, only the dated version applies to this specification; for undated reference documents, the latest version (including all amendments) is applicable to this specification.
3 Term
3.1 Spectral density of radiant flux at the wavelength lambda, the ratio of the radiant flux dphie to dlambda in the wavelength element dlambda containing lambda, the symbol of this quantity is phielambda(lambda), and the unit is W/nm.
3.2 Total spectral radiant flux is the spectral density of the radiant flux in the whole space, in W/nm.
3.3 Spectral total radiant flux standard lamp A specific light source used to maintain and transmit the total radiant flux value of the spectrum of a certain wavelength or wavelength range.
4 overview
The total spectral radiant flux lamp is used to transmit the total spectral radiant flux value of a certain wavelength or wavelength range, generally special Selected incandescent lamps, bromine tungsten lamps, LED lamps or other light sources. After aging according to the specified conditions, according to the specified ignition bar the total spectral radiant flux of the lamp has good repeatability and long-term stability.
Integrating sphere spectroradiometer is commonly used in the evaluation of light source characteristics to measure the total luminous flux and color parameters of the light source.
The total radiant flux lamp can realize the transfer of these two values at the same time, and is widely used in the field of optical radiation measurement.
5 Metrological characteristics the total radiant flux of the spectrum (the calibrated spectral range of the quantity is 350nm~1100nm).
6 Calibration conditions
6.1 Environmental conditions the temperature of the laboratory should be in the range of (23±3)°C, and the temperature change during the measurement process should not exceed 3°C, Relative humidity <=80%. The environment should be clean, free of corrosive gas, and no dust, vibration and electromagnetic field interference that affect the normal operation of the instrument.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 11 pages — is available in the English PDF.
How to Download JJF 1807-2020
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Fast delivery
After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
JJF 2425-2026 — Calibration specification for carbon dioxide incubators
JJF 1183-2025 — Calibration Specification for Temperature Transmitters
JJF 1282-2025 — Calibration Specification for Time Delay Relays
JJF 1807-2020
$225.00