Valid

JJF 1799-2020Calibration Specification for Test Devices for Action Characteristics of Low Voltage Circuit Breakers (English PDF)

低压断路器动作特性试验台校准规范

Preview PDF

This is a limited preview

Buy now to download the full PDF (14 pages)

Need quotation for your management?

Get a formal quotation for JJF 1799-2020 in 30 minutes.

Issued by

State Administration for Market Regulation

Level / Type

National · Mandatory

Issue date

January 1, 2020

Implementation date

April 17, 2020

Scope

JJF 1799-2020 is the English-translated version of 低压断路器动作特性试验台校准规范.

JJF 1799-2020 is the Chinese standard "Calibration Specification for Test Devices for Action Characteristics of Low Voltage Circuit Breakers".

Found what you need?

Document preview — JJF 1799-2020

National Standard of the People's Republic of China

ICS
17.220

Contents

  • Introduction (II)
  • 1 Scope (1)
  • 2 Terms and measurement units (1)
  • 2.1 Delay test (1)
  • 2.2 Transient test (1)
  • 2.3 The area difference between the positive and negative half-waves of the first cycle (1)
  • 2.4 Deviation value of crest factor (1)
  • 3 Overview (1)
  • 4 Measurement characteristics (1)
  • 4.1 Output current (1)
  • 4.2 Current duration (2)
  • 4.3 Harmonic distortion(2)
  • 4.4 The area difference between the positive and negative half-waves of the first cycle (2)
  • 4.5 Deviation value of crest factor (2)
  • 4.6 Output current stability (2)
  • 5 Calibration conditions (2)
  • 5.1 Environmental conditions (2)
  • 5.2 Measurement standards and other equipment (2)
  • 6 Calibration items and calibration methods (2)
  • 6.1 Calibration items (2)
  • 6.2 Calibration method (3)
  • 7 Expression of calibration results (6)
  • 7.1 Calibration certificate (6)
  • 7.2 Data processing(6)
  • 8 Recalibration interval (6)
  • Appendix A Evaluation Example of Measurement Uncertainty (7)
  • Appendix B Calibration Original Record Format (11)
  • Appendix C Internal Page (Page 2) Format of Calibration Certificate (13)
  • Appendix D Calibration Certificate Calibration Results Page (Page 3) Format (14)

1 Scope (1)

2 Terms and measurement units (1)

2.1 Delay test (1)

2.2 Transient test (1)

2.3 The area difference between the positive and negative half-waves of the first cycle (1)

2.4 Deviation value of crest factor (1)

3 Overview (1)

4 Measurement characteristics (1)

4.1 Output current (1)

4.2 Current duration (2)

4.3 Harmonic distortion(2)

4.4 The area difference between the positive and negative half-waves of the first cycle (2)

4.5 Deviation value of crest factor (2)

4.6 Output current stability (2)

5 Calibration conditions (2)

5.1 Environmental conditions (2)

5.2 Measurement standards and other equipment (2)

6 Calibration items and calibration methods (2)

6.1 Calibration items (2)

6.2 Calibration method (3)

7 Expression of calibration results (6)

7.1 Calibration certificate (6)

7.2 Data processing(6)

8 Recalibration interval (6)

Appendix A Evaluation Example of Measurement Uncertainty (7)

Appendix B Calibration Original Record Format (11)

Appendix C Internal Page (Page 2) Format of Calibration Certificate (13)

Appendix D Calibration Certificate Calibration Results Page (Page 3) Format (14)

Introduction

This specification is based on JJF 1071-2010 "Rules for the Compilation of National Metrology and Calibration Specifications", JJF 1059.1-2012 Compilation of "Evaluation and Expression of Measurement Uncertainty".

This specification is released for the first time.

Calibration specification for low-voltage circuit breaker operating characteristic test bench

1 Scope

This specification is applicable to the calibration of low-voltage circuit breaker operating characteristic test benches under power frequency.

2 Terms and units of measurement

2.1 Delay test Test to verify whether the delay characteristics of circuit breakers and other protective devices meet the requirements of the standard.

2.2 Instantaneous test Test to verify whether the instantaneous characteristics of circuit breakers and other protective devices meet the requirements of the standard.

2.3 The area difference between the positive and negative half-waves of the first cycle the difference between the area of the positive half-wave and the negative half-wave of the first sine wave is an index used to measure the asymmetry of the current.

2.4 Deviationofcrestfactor the ratio of the peak value to the effective value of the first cycle waveform deviates from the standard value (the standard value of the crest factor of the sine wave is 2) Percentage.

3 overview

The low-voltage circuit breaker action characteristic test bed (hereinafter referred to as the test bed) is a kind of overcurrent protection used to detect circuit breakers an instrument with electrical tripping characteristics. The test rig is divided into two types. time delay test rig and instantaneous test rig. Detection of overload conditions the test bench for the lower tripping characteristics is called the delay test bench; the test bench for detecting the tripping characteristics under short-circuit conditions is called the instantaneous test bench.

Test bench.

The test bench is mainly composed of voltage regulator, multi-magnetic circuit transformer, current measurement module, time measurement module and other parts.

The test bench controls the output voltage of the multi-magnetic circuit transformer by adjusting the voltage of the voltage regulator, and outputs the delay or Instantaneous current value, and shows the tripping current and tripping time of the circuit breaker. The principle is shown in Figure 1.

Figure 1 Schematic diagram of the test bench

4 Measurement characteristics

4.1 Output current

The output current of the test bench should meet.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 14 pages — is available in the English PDF.

How to Download JJF 1799-2020

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Fast delivery

    After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
14 pages
Fast delivery
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

JJF 1799-2020

$300.00