JJF 1795-2020Calibration Specification for Camshaft Measuring Instruments (English PDF)
凸轮轴测量仪校准规范
This is a limited preview
Buy now to download the full PDF (12 pages)
Need quotation for your management?
Get a formal quotation for JJF 1795-2020 in 30 minutes.
Issued by
State Administration for Market Regulation
Level / Type
National · Mandatory
Issue date
January 1, 2020
Implementation date
April 17, 2020
Scope
JJF 1795-2020 is the English-translated version of 凸轮轴测量仪校准规范.
JJF 1795-2020 is the Chinese standard "Calibration Specification for Camshaft Measuring Instruments".
Found what you need?
Document preview — JJF 1795-2020
National Standard of the People's Republic of China
- ICS
- 17.040
Contents
- Introduction (II)
- 1 Scope (1)
- 2 Reference documents (1)
- 3 Terms and definitions (1)
- 4 Overview (1)
- 5 Measurement characteristics (2)
- 6 Calibration conditions (2)
- 6.1 Calibration items and main calibration instruments (2)
- 6.2 Environmental conditions (3)
- 7 Calibration items and calibration methods (3)
- 7.1 Oblique runout of spindle center (3)
- 7.2 Coaxiality of the two centers (4)
- 7.3 Parallelism to the top line when the axial measuring device moves (4)
- 7.4 The verticality of the line connecting the center to the center when the radial measuring device moves (4)
- 7.5 Indication error of radial measurement (5)
- 7.6 Repeatability of radial measurement (5)
- 7.7 Indication error of angle measurement (5)
- 7.8 Measurement repeatability of starting point (6)
- 7.9 Lift measurement error (6)
- 8 Calibration result expression (6)
- 9 Recalibration interval (6)
- Appendix A. Calibration Uncertainty Evaluation Example of Lift Measurement Error (7)
- Appendix B Reference Legend for Standard Eccentric Shaft and Special Mandrel (11)
1 Scope (1)
2 Reference documents (1)
3 Terms and definitions (1)
4 Overview (1)
5 Measurement characteristics (2)
6 Calibration conditions (2)
6.1 Calibration items and main calibration instruments (2)
6.2 Environmental conditions (3)
7 Calibration items and calibration methods (3)
7.1 Oblique runout of spindle center (3)
7.2 Coaxiality of the two centers (4)
7.3 Parallelism to the top line when the axial measuring device moves (4)
7.4 The verticality of the line connecting the center to the center when the radial measuring device moves (4)
7.5 Indication error of radial measurement (5)
7.6 Repeatability of radial measurement (5)
7.7 Indication error of angle measurement (5)
7.8 Measurement repeatability of starting point (6)
7.9 Lift measurement error (6)
8 Calibration result expression (6)
9 Recalibration interval (6)
Appendix A. Calibration Uncertainty Evaluation Example of Lift Measurement Error (7)
Appendix B Reference Legend for Standard Eccentric Shaft and Special Mandrel (11)
Introduction
This specification is based on JJF 1071-2010 "Rules for the Compilation of National Metrology and Calibration Specifications", JJF 1001-2011 "Tong Compile with Metrology Terms and Definitions and JJF 1059.1-2012 "Evaluation and Expression of Measurement Uncertainty".
This specification is released for the first time.
Calibration specification for camshaft measuring instrument
1 Scope
This specification applies to the calibration of vertical and horizontal camshaft measuring instruments with a center distance of no more than 600mm.
2 Reference documents this specification refers to the following documents.
JJG57 optical and digital indexing head JJF 1561 Gear Measurement Center Calibration Specification for dated reference documents, only the dated version applies to this specification; for undated references the latest version (including all amendments) is applicable to this specification.
3 Terms and definitions
3.1 Lift of the camshaft the amount of change in the working radius of the camshaft in the reference direction during the rotation of the camshaft around the axis.
3.2 Cam phase angle phaseangleofthecamshaft the angle between the specified point on the cam profile and the base circle axis relative to the reference plane.
Note. The designated point can be the starting point or the highest point of the lift. The reference plane can be the center plane of the positioning keyway or the reference cam flat.
3.3 sensitivepoint
When the camshaft rotates around the axis, the point where the lift change speed is the largest is called the sensitive point.
4 overview
Camshaft is the main component in engine and oil pump. The camshaft measuring instrument can measure the lift and phase angle of the camshaft and other geometric parameters. The camshaft measuring instrument is mainly divided into automatic type and manual type according to the movement form of the instrument. automatic the type is mainly vertical structure [Figure 1 (a)], a small amount is horizontal structure [Figure 1 (b)]; manual type is usually used Horizontal structure, including optical mechanical type, grating digital type, etc.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 12 pages — is available in the English PDF.
How to Download JJF 1795-2020
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Fast delivery
After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
JJF 2425-2026 — Calibration specification for carbon dioxide incubators
JJF 1183-2025 — Calibration Specification for Temperature Transmitters
JJF 1282-2025 — Calibration Specification for Time Delay Relays
JJF 1795-2020
$255.00