JJF 1785-2019Program of Pattern Evaluation of Breath Alcohol Analyzers (English PDF)
呼出气体酒精含量检测仪型式评价大纲
This is a limited preview
Buy now to download the full PDF (32 pages)
Need quotation for your management?
Get a formal quotation for JJF 1785-2019 in 30 minutes.
Issued by
State Administration for Market Regulation
Level / Type
National · Mandatory
Issue date
January 1, 2019
Implementation date
March 31, 2020
Scope
JJF 1785-2019 is the English-translated version of 呼出气体酒精含量检测仪型式评价大纲.
JJF 1785-2019 is the Chinese standard "Program of Pattern Evaluation of Breath Alcohol Analyzers".
Found what you need?
Document preview — JJF 1785-2019
National Standard of the People's Republic of China
- ICS
- 17.020
Contents
- Introduction (III)
- 1 Scope (1)
- 2 References (1)
- 3 Overview (1)
- 4 Legal management requirements (1)
- 4.1 Unit of measurement (1)
- 4.2 Marks and logos (2)
- 5 Measurement requirements (2)
- 5.1 Indication error (2)
- 5.2 Repeatability (2)
- 5.3 Drift (2)
- 5.4 Measurement range, resolution and measurement unit conversion (2)
- 5.5 Round down (2)
- 5.6 Anti-interference ability (2)
- 5.7 Minimum expiratory flow and shortest duration (2)
- 5.8 Expiratory resistance (2)
- 5.9 Residual memory effect (2)
- 5.10 Minimum expiratory volume (2)
- 5.11 Expiratory duration effect (3)
- 5.12 Expiratory volume effect (3)
- 5.13 Reset to zero (3)
- 6 General technical requirements (3)
- 6.1 Appearance and structure (3)
- 6.2 Function check (3)
- 6.3 Long-term stability (3)
- 6.4 Environmental adaptability (3)
- 7 Type evaluation project table (4)
- 8 Number of prototypes provided and how to use them (5)
- 8.1 Number of prototypes provided (5)
- 8.2 How to use the prototype (5)
- 9 Test methods and conditions of test items, data processing and qualification criteria (5)
- 9.1 Test conditions (5)
- 9.2 Test equipment (5)
- 9.3 Test method (6)
- 10 Measuring instruments and equipment used in the test project (17)
- 11 Determination of type evaluation results (18)
- 12 Type evaluation original record format (18)
- Appendix A Requirements for Ethanol Standard Gases in Air (19)
- Appendix B Concentration of alcohol in exhaled breath (mole fraction µmol/mol) and mass concentration of alcohol in exhaled breath (mg/L)
1 Scope (1)
2 References (1)
3 Overview (1)
4 Legal management requirements (1)
4.1 Unit of measurement (1)
4.2 Marks and logos (2)
5 Measurement requirements (2)
5.1 Indication error (2)
5.2 Repeatability (2)
5.3 Drift (2)
5.4 Measurement range, resolution and measurement unit conversion (2)
5.5 Round down (2)
5.6 Anti-interference ability (2)
5.7 Minimum expiratory flow and shortest duration (2)
5.8 Expiratory resistance (2)
5.9 Residual memory effect (2)
5.10 Minimum expiratory volume (2)
5.11 Expiratory duration effect (3)
5.12 Expiratory volume effect (3)
5.13 Reset to zero (3)
6 General technical requirements (3)
6.1 Appearance and structure (3)
6.2 Function check (3)
6.3 Long-term stability (3)
6.4 Environmental adaptability (3)
7 Type evaluation project table (4)
8 Number of prototypes provided and how to use them (5)
8.1 Number of prototypes provided (5)
8.2 How to use the prototype (5)
9 Test methods and conditions of test items, data processing and qualification criteria (5)
9.1 Test conditions (5)
9.2 Test equipment (5)
9.3 Test method (6)
10 Measuring instruments and equipment used in the test project (17)
11 Determination of type evaluation results (18)
12 Type evaluation original record format (18)
Appendix A Requirements for Ethanol Standard Gases in Air (19)
Appendix B Concentration of alcohol in exhaled breath (mole fraction µmol/mol) and mass concentration of alcohol in exhaled breath (mg/L)
And conversion of blood alcohol concentration (mg/100mL) (20) Appendix C. Original record format of type evaluation of exhaled gas alcohol content detector (21)
Introduction
This type evaluation outline is based on JJF 1016-2014 "Guidelines for Compiling Type Evaluation Outline of Measuring Instruments", JJF 1015-2014 "General Specification for Type Evaluation of Measuring Instruments" and JJF 1001-2011 "General Terms and Definitions for Measuring Compiled by Yi.
The technical indicators of this type evaluation outline refer to JJG657-2019 "Exhaled Gas Alcohol Content Detector", GB/T 21254-2017 "Exhaled Gas Alcohol Content Detector" and OIMLR-126 (2012) "Exhaled Gas Alcohol Technical documents such as "Evidentialbreathanalyzers".
This type evaluation outline is released for the first time.
Outline of Type Evaluation of Exhaled Gas Alcohol Content Detector
1 Scope
This type of evaluation outline is applicable to the exhalation gas alcohol content detector with the classification code of measuring instrument 46580000 Type evaluation.
2 Reference documents JJG657-2019 exhaled gas alcohol content detector GB/T 11606-2007 Environmental testing methods of analytical instruments GB/T 17626.2-2018 Electromagnetic Compatibility Test and Measurement Technology Electrostatic Discharge Immunity Test GB/T 17626.3-2016 Electromagnetic compatibility test and measurement technology RF electromagnetic field radiation immunity test GB/T 18268.1-2010 Electromagnetic compatibility requirements for electrical equipment for measurement, control, and laboratory use Part. General requirements GB/T 21254-2017 Exhaled gas alcohol content detector OIMLR-126 (2012) Exhaled gas alcohol content detector (Evidentialbreathanalyzers) for dated reference documents, only the dated version applies to this outline; for those without date references the latest version (including all amendments) is applicable to this outline.
3 Overview
Exhaled breath alcohol content detector (hereinafter referred to as wine detector) is used to detect the alcohol content in human exhaled breath the amount. The wine detector consists of gas circuit, control circuit, alcohol sensor, breath detection system, sampling system and display printing system and other components. According to the measurement principle, the wine detector can be divided into fuel cell type (ie electrochemical type), semiconductor type and infrared Type and so on.
Among them, alcohol sensors, pressure sensors and temperature sensors are the key components and materials that affect the metering performance.
See Table 1.
Table 1 Key parts and materials table
No. Name Main Performance Index Remarks
1 Alcohol sensor
2 Pressure sensor
3 Temperature sensor
4 Legal management requirements
4.1 Unit of measurement the wine inspection instrument shall adopt the legal unit of measurement.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 32 pages — is available in the English PDF.
How to Download JJF 1785-2019
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Fast delivery
After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
JJF 2425-2026 — Calibration specification for carbon dioxide incubators
JJF 1183-2025 — Calibration Specification for Temperature Transmitters
JJF 1282-2025 — Calibration Specification for Time Delay Relays
JJF 1785-2019