Document preview — JJF 1782-2019
National Standard of the People's Republic of China
- ICS
- 17.100
Contents
- Introduction (IV)
- 1 Scope (1)
- 2 References (1)
- 3 Terminology (1)
- 3.1 Rated pressure (1)
- 3.2 Alarm pressure (1)
- 3.3 Locking pressure (1)
- 3.4 Overpressure alarm pressure (2)
- 3.5 Set point deviation (2)
- 3.6 Switching difference (2)
- 3.7 Static pressure test (2)
- 4 Overview (2)
- 5 Legal management requirements (2)
- 5.1 Unit of measurement (2)
- 5.2 External structure (2)
- 5.3 Logo (2)
- 5.4 Provide technical documents for review (3)
- 6 Measurement requirements (3)
- 6.1 Indicating device (3)
- 6.2 Accuracy class (3)
- 6.3 Zero error (3)
- 6.4 Indication error (3)
- 6.5 Return error (3)
- 6.6 Error of rated pressure (3)
- 6.7 Tap Displacement (3)
- 6.8 Pointer deflection stability (3)
- 6.9 Tightness (3)
- 6.10 Set point deviation and switching difference (4)
- 6.11 Temperature compensation (4)
- 7 General technical requirements (5)
- 7.1 Appearance and structure (5)
- 7.2 Static pressure test (5)
- 7.3 Alternating pressure (5)
- 7.4 Temperature cycle test (5)
- 7.5 Insulation resistance (5)
- 7.6 Dielectric strength (5)
- 7.7 Enclosure protection (6)
- 7.8 Lightning impulse test (6)
- 7.9 Contact breaking function of electrical signal device (6)
- 7.10 Vibration resistance to working environment (6)
- 8 Type evaluation item table (6)
- 9 Provide the number of prototypes and how to use them (7)
- 9.1 Number of prototypes provided (7)
- 9.2 How to use the prototype (7)
- 10 Test methods and conditions, test data processing and acceptance criteria (7)
- 10.1 Environmental conditions (7)
- 10.2 Working medium (8)
- 10.3 Test points (8)
- 10.4 Test sequence (8)
- 10.5 Indication device (8)
- 10.6 Accuracy class (8)
- 10.7 Zero error (8)
- 10.8 Indication error (8)
- 10.9 Return error (9)
- 10.10 Error of rated pressure (9)
- 10.11 Tap Displacement (9)
- 10.12 Stability of pointer deflection (9)
- 10.13 Sealability (9)
- 10.14 Setpoint deviation and switching difference (10)
- 10.15 Temperature compensation (10)
- 10.16 Appearance and Structure (11)
- 10.17 Static pressure test (11)
- 10.18 Alternating pressure (11)
- 10.19 Temperature cycle test (11)
- 10.20 Insulation resistance (12)
- 10.21 Dielectric strength (12)
- 10.22 Enclosure protection (12)
- 10.23 Lightning impulse test (12)
- 10.24 Contact making and breaking function of electrical signal devices (12)
- 10.25 Vibration resistance to working environment (13)
- 11 Table of measuring instruments and equipment used in the test project
- 12 Judgment principles of type evaluation results (14)
- Appendix A Test sequence and intermittent time between items (15)
- Appendix B Type Evaluation Record Format (16)
1 Scope (1)
2 References (1)
3 Terminology (1)
3.1 Rated pressure (1)
3.2 Alarm pressure (1)
3.3 Locking pressure (1)
3.4 Overpressure alarm pressure (2)
3.5 Set point deviation (2)
3.6 Switching difference (2)
3.7 Static pressure test (2)
4 Overview (2)
5 Legal management requirements (2)
5.1 Unit of measurement (2)
5.2 External structure (2)
5.3 Logo (2)
5.4 Provide technical documents for review (3)
6 Measurement requirements (3)
6.1 Indicating device (3)
6.2 Accuracy class (3)
6.3 Zero error (3)
6.4 Indication error (3)
6.5 Return error (3)
6.6 Error of rated pressure (3)
6.7 Tap Displacement (3)
6.8 Pointer deflection stability (3)
6.9 Tightness (3)
6.10 Set point deviation and switching difference (4)
6.11 Temperature compensation (4)
7 General technical requirements (5)
7.1 Appearance and structure (5)
7.2 Static pressure test (5)
7.3 Alternating pressure (5)
7.4 Temperature cycle test (5)
7.5 Insulation resistance (5)
7.6 Dielectric strength (5)
7.7 Enclosure protection (6)
7.8 Lightning impulse test (6)
7.9 Contact breaking function of electrical signal device (6)
7.10 Vibration resistance to working environment (6)
8 Type evaluation item table (6)
9 Provide the number of prototypes and how to use them (7)
9.1 Number of prototypes provided (7)
9.2 How to use the prototype (7)
10 Test methods and conditions, test data processing and acceptance criteria (7)
10.1 Environmental conditions (7)
10.2 Working medium (8)
10.3 Test points (8)
10.4 Test sequence (8)
10.5 Indication device (8)
10.6 Accuracy class (8)
10.7 Zero error (8)
10.8 Indication error (8)
10.9 Return error (9)
10.10 Error of rated pressure (9)
10.11 Tap Displacement (9)
10.12 Stability of pointer deflection (9)
10.13 Sealability (9)
10.14 Setpoint deviation and switching difference (10)
10.15 Temperature compensation (10)
10.16 Appearance and Structure (11)
10.17 Static pressure test (11)
10.18 Alternating pressure (11)
10.19 Temperature cycle test (11)
10.20 Insulation resistance (12)
10.21 Dielectric strength (12)
10.22 Enclosure protection (12)
10.23 Lightning impulse test (12)
10.24 Contact making and breaking function of electrical signal devices (12)
10.25 Vibration resistance to working environment (13)
11 Table of measuring instruments and equipment used in the test project
12 Judgment principles of type evaluation results (14)
Appendix A Test sequence and intermittent time between items (15)
Appendix B Type Evaluation Record Format (16)
Introduction
JJF 1001 "General Measurement Terms and Definitions", JJF 1059 "Measurement Uncertainty Evaluation and Representation" the basic series of specifications formulated in this outline.
The requirements and methods of the test items in this outline refer to JJG1073-2011 "Pressure Type SF6 Gas Density the content of "Controller" and GB/T 22065-2008 "Pressure Type SF6 Gas Density Controller" requires it can objectively, comprehensively and effectively evaluate the performance of the pressure type sulfur hexafluoride gas density controller.
The structure of this outline is arranged in accordance with JJF 1016-2014 "Guidelines for the Compilation of Outlines for Measuring Apparatus Type Evaluation".
Each chapter is prepared in accordance with the provisions of JJF 1015-2014 "General Specification for Type Evaluation of Measuring Instruments".
This outline is published for the first time.
Pressure type SF6 gas density Controller type evaluation outline
1 Scope
This outline applies to the classification code of measuring instruments is 12320000, with spring tube or bellows as the measuring element, measuring the volume range is (-0.1 ~ 0.9) MPa or (-0.1 ~ 0.5) MPa, the nominal diameter of the instrument shell is 100mm, the pressure type sulfur hexafluoride (SF6) gas density controller (or gas density relay) whose working medium is sulfur hexafluoride gas Type evaluation of electrical appliances, gas density monitors, hereinafter referred to as "controller").
2 Reference documents the outline refers to the following documents.
JJG1073-2011 Pressure type sulfur hexafluoride gas density controller GB/T 2423.10 Environmental testing for electrical and electronic products Part 2: Test methods Test Fc. Vibration (Sine) GB/T 4208 enclosure protection level (IP code) GB/T 11287 Electrical relays Part 21: Vibration, shock, impact of measuring relays and protection devices Impact and earthquake test part 1.vibration test (sine) GB/T 14598.3-2006 Electrical relays Part 5: Insulation configuration of measuring relays and protection devices Meet the requirements and test GB/T 15823 Non-destructive testing helium leak detection method GB/T 22065-2008 Pressure type sulfur hexafluoride gas density controller JB/T 5528-2005 Pressure gauge scale and division JB/T 9252-1999 The basic type, size and pointer General technical requirements for dated reference documents, only the dated version applies to this outline; for those without date references the latest version (including all amendments) is applicable to this outline.
3 Terminology
3.1 Rated pressure ratingpressure Under standard atmospheric pressure conditions, before the equipment is put into operation or when supplementing gas, fill the equipment gas chamber with SF6 as required the pressure of the gas. [JJG1073-2011 Terms and Definitions 3.1]
3.2 Alarm pressure
When the pressure of SF6 gas in the equipment gas chamber drops to a certain set value, the controller will send out an alarm signal.
The set value is called the alarm pressure.
Note. Rewritten from JJG1073-2011 Terms and Definitions 3.2.
3.3 Locking pressure atresiapressure when the pressure of SF6 gas in the equipment gas chamber drops to a certain set value, the controller will send a blocking signal.
The fixed value is called blocking pressure.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 23 pages — is available in the English PDF.
How to Download JJF 1782-2019
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Fast delivery
After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
JJF 2425-2026 — Calibration specification for carbon dioxide incubators
JJF 1183-2025 — Calibration Specification for Temperature Transmitters
JJF 1282-2025 — Calibration Specification for Time Delay Relays
JJF 1782-2019
$500.00