JJF 1781-2019Program of Pattern Evaluation of Applanation Tonometers (English PDF)
接触式压平眼压计型式评价大纲
This is a limited preview
Buy now to download the full PDF (13 pages)
Need quotation for your management?
Get a formal quotation for JJF 1781-2019 in 30 minutes.
Issued by
State Administration for Market Regulation
Level / Type
National · Mandatory
Issue date
January 1, 2019
Implementation date
March 31, 2020
Scope
JJF 1781-2019 is the English-translated version of 接触式压平眼压计型式评价大纲.
JJF 1781-2019 is the Chinese standard "Program of Pattern Evaluation of Applanation Tonometers".
Found what you need?
Document preview — JJF 1781-2019
National Standard of the People's Republic of China
- ICS
- 17.100
Contents
- Introduction (II)
- 1 Scope (1)
- 2 References (1)
- 3 Terms and definitions (1)
- 4 Overview (1)
- 5 Legal management requirements (2)
- 5.1 Requirements for units of measurement (2)
- 5.2 Measurement legality marks and measurement equipment marking requirements (2)
- 5.3 Technical information that the applicant should submit (2)
- 6 Measurement requirements (3)
- 6.1 Force error (3)
- 6.2 Flattened circle diameter (3)
- 6.3 Flatness of the front surface of the measuring head (3)
- 7 General technical requirements (3)
- 7.1 Appearance (3)
- 7.2 Climate environment adaptability (4)
- 8 Type evaluation item table (4)
- 9 Provide the number of prototypes and how to use them (4)
- 9.1 Number of test prototypes (4)
- 9.2 Use of prototype (4)
- 10 Test methods and conditions of test items, data processing and qualification criteria (4)
- 10.1 Force error (4)
- 10.2 Flattened circle diameter (5)
- 10.3 Flatness of the front surface of the measuring head (6)
- 10.4 Rated working low temperature test (7)
- 10.5 Rated working high temperature test (8)
- 10.6 Judgment of type evaluation results (8)
- 11 Table of measuring instruments and equipment used in the test project (8)
- 12 Type evaluation record format (9)
- Appendix A Appraisal Record Format for Flattened Tonometer Type (10)
1 Scope (1)
2 References (1)
3 Terms and definitions (1)
4 Overview (1)
5 Legal management requirements (2)
5.1 Requirements for units of measurement (2)
5.2 Measurement legality marks and measurement equipment marking requirements (2)
5.3 Technical information that the applicant should submit (2)
6 Measurement requirements (3)
6.1 Force error (3)
6.2 Flattened circle diameter (3)
6.3 Flatness of the front surface of the measuring head (3)
7 General technical requirements (3)
7.1 Appearance (3)
7.2 Climate environment adaptability (4)
8 Type evaluation item table (4)
9 Provide the number of prototypes and how to use them (4)
9.1 Number of test prototypes (4)
9.2 Use of prototype (4)
10 Test methods and conditions of test items, data processing and qualification criteria (4)
10.1 Force error (4)
10.2 Flattened circle diameter (5)
10.3 Flatness of the front surface of the measuring head (6)
10.4 Rated working low temperature test (7)
10.5 Rated working high temperature test (8)
10.6 Judgment of type evaluation results (8)
11 Table of measuring instruments and equipment used in the test project (8)
12 Type evaluation record format (9)
Appendix A Appraisal Record Format for Flattened Tonometer Type (10)
Introduction
This type evaluation outline is based on JJF 1015-2014 "General Specification for Type Evaluation of Measuring Instruments", JJF 1016-2014 "Guidelines for the Compilation of the Outline of Type Appraisal of Measuring Instruments" was prepared.
The technical indicators of this type evaluation outline refer to JJG1141-2017 "Contact Flattening Tonometer", GB/T 14710-2009 "Environmental requirements and test methods for medical appliances" and ISO 8612.:2009 "Ophthalmic instruments "Tonometer" and other technical documents.
This type evaluation outline is released for the first time.
Outline of Type Evaluation of Contact Squeezing Tonometer
1 Scope
This type of evaluation outline is applicable to the range of optical-mechanical structure and measuring head force (hereinafter referred to as force) to Including (0 ~ 49) mN contact applanation tonometer (hereinafter referred to as applanation tonometer) type evaluation
2 Reference documents the following documents are cited in this type evaluation outline.
JJG1141-2017 contact flattening tonometer GB/T 14710-2009 Environmental requirements and test methods for medical appliances ISO 8612.:2009 Ophthalmic instruments tonometer (Ophthalmicinstruments-Tonometers) for dated reference documents, only the dated version is applicable to this type of evaluation outline; those that are not dated the latest version (including all amendments) of the cited documents is applicable to this type evaluation outline.
3 Terms and definitions 3.1 intraocular pressure; IOP the pressure in the eyeball, referred to as intraocular pressure. The unit is kilopascal (kPa).
[ISO 8612.:2009, definition 3.1]
4 Overview
The flattened tonometer is a special instrument used to measure the intraocular pressure in the ophthalmology diagnosis.
The working principle of the flattened tonometer is based on the Imbert-Fick principle. treating the eyeball as an ideal dry surface Elastic thin-walled sphere, the intraocular pressure p, the force F and the flattened area A of the cornea have the formula (1) relationship.
p = F/A (1)
When measuring, it is usually used in conjunction with a slit lamp, and the measuring head of a flattened tonometer is used to flatten the cornea and root of a certain area.
According to the required force to measure the intraocular pressure (see Figure 1).
Figure 1 Schematic diagram of flattening the tonometer
The flattened tonometer can be divided into two types of scale type and digital display type according to the display method, mainly by the measuring head, measuring arm,
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 13 pages — is available in the English PDF.
How to Download JJF 1781-2019
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Fast delivery
After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
JJF 2425-2026 — Calibration specification for carbon dioxide incubators
JJF 1183-2025 — Calibration Specification for Temperature Transmitters
JJF 1282-2025 — Calibration Specification for Time Delay Relays
JJF 1781-2019
$355.00