JJF 1770-2019Rules of Metrology Testing for Energy Efficiency of Multi-connected Air-condition(heat pump) Units (English PDF)
多联式空调(热泵)机组能源效率计量检测规则
This is a limited preview
Buy now to download the full PDF (27 pages)
Need quotation for your management?
Get a formal quotation for JJF 1770-2019 in 30 minutes.
Issued by
State Administration for Market Regulation
Level / Type
National · Mandatory
Issue date
January 1, 2019
Implementation date
December 27, 2019
Scope
JJF 1770-2019 is the English-translated version of 多联式空调(热泵)机组能源效率计量检测规则.
JJF 1770-2019 is the Chinese standard "Rules of Metrology Testing for Energy Efficiency of Multi-connected Air-condition(heat pump) Units".
Found what you need?
Document preview — JJF 1770-2019
National Standard of the People's Republic of China
- ICS
- 17.020
Contents
- Introduction (II)
- 1 Scope (1)
- 2 Reference documents (1)
- 3 Terms and measurement units (1)
- 3.1 Cooling capacity(1)
- 3.2 Cooling power consumption (1)
- 3.3 Refrigeration energy efficiency ratio (1)
- 3.4 Refrigeration comprehensive performance coefficient [IPLV (C)] (1)
- 3.5 Energy efficiency limit value (2)
- 3.6 Energy efficiency rating (2)
- 3.7 Air enthalpy difference method (2)
- 4 Overview (2)
- 5 Measurement requirements (2)
- 5.1 Energy efficiency labeling (2)
- 5.2 Energy efficiency indicators (energy consumption) (2)
- 5.3 Energy efficiency rating (3)
- 6 Testing conditions (3)
- 6.1 Environmental conditions (3)
- 6.2 Measuring equipment (3)
- 6.3 Measurement uncertainty (4)
- 7 Test items and methods (4)
- 7.1 Sampling principles and methods (4)
- 7.2 Sample testing (4)
- 7.3 Original record (6)
- 7.4 Data processing(6)
- 8 Test results (6)
- 8.1 Eligibility criteria for energy efficiency indicators (energy consumption) measurement test results (6)
- 8.2 Judgment criteria for test results (7)
- 8.3 Test report(8)
- Appendix A Multi-connected cooling capacity air enthalpy difference measurement method (9)
- Appendix B Test and calculation of multi-line refrigeration comprehensive performance coefficient [IPLV (C)] (14)
- Appendix C Example of Uncertainty Evaluation of Indoor Air Enthalpy Difference Method Multi-connected Energy Efficiency Measurement (17)
- Appendix D Multi-connected air conditioning (heat pump) unit energy efficiency measurement test sampling sheet (format) (27)
- Appendix E. Original record of energy efficiency measurement and inspection of multi-connected air-conditioning (heat pump) units (format) (28)
- Appendix F Multi-connected air conditioning (heat pump) unit energy efficiency measurement test report (format) (31)
1 Scope (1)
2 Reference documents (1)
3 Terms and measurement units (1)
3.1 Cooling capacity(1)
3.2 Cooling power consumption (1)
3.3 Refrigeration energy efficiency ratio (1)
3.4 Refrigeration comprehensive performance coefficient [IPLV (C)] (1)
3.5 Energy efficiency limit value (2)
3.6 Energy efficiency rating (2)
3.7 Air enthalpy difference method (2)
4 Overview (2)
5 Measurement requirements (2)
5.1 Energy efficiency labeling (2)
5.2 Energy efficiency indicators (energy consumption) (2)
5.3 Energy efficiency rating (3)
6 Testing conditions (3)
6.1 Environmental conditions (3)
6.2 Measuring equipment (3)
6.3 Measurement uncertainty (4)
7 Test items and methods (4)
7.1 Sampling principles and methods (4)
7.2 Sample testing (4)
7.3 Original record (6)
7.4 Data processing(6)
8 Test results (6)
8.1 Eligibility criteria for energy efficiency indicators (energy consumption) measurement test results (6)
8.2 Judgment criteria for test results (7)
8.3 Test report(8)
Appendix A Multi-connected cooling capacity air enthalpy difference measurement method (9)
Appendix B Test and calculation of multi-line refrigeration comprehensive performance coefficient [IPLV (C)] (14)
Appendix C Example of Uncertainty Evaluation of Indoor Air Enthalpy Difference Method Multi-connected Energy Efficiency Measurement (17)
Appendix D Multi-connected air conditioning (heat pump) unit energy efficiency measurement test sampling sheet (format) (27)
Appendix E. Original record of energy efficiency measurement and inspection of multi-connected air-conditioning (heat pump) units (format) (28)
Appendix F Multi-connected air conditioning (heat pump) unit energy efficiency measurement test report (format) (31)
Introduction
In order to standardize the implementation of energy efficiency labeling management of multi-unit air conditioning (heat pump) units (hereinafter referred to as "multi-unit Machine") energy efficiency measurement and testing work, according to JJF 1261.1-2017 "Energy efficiency measurement and testing of energy-using products According to the requirements of the Rules, this specification is formulated.
This specification is released for the first time.
Multi-connected air conditioning (heat pump) unit Energy efficiency measurement and testing rules
1 Scope
This specification specifies the energy efficiency measurement requirements, measurement testing procedures, and Measurement and testing methods, measurement and testing results evaluation criteria and testing reports, etc.
This specification applies to multi-line energy efficiency measurement supervision and testing, and commissioned testing can refer to this specification. Production and Sales of multi-line units can also refer to this specification for testing.
The multi-line energy efficiency measurement and detection method specified in this specification is the air enthalpy difference method.
This specification does not apply to units with dual refrigeration cycle systems and multiple refrigeration cycle systems.
The multi-line tested should be products that have passed the self-inspection of the manufacturer, or the products imported and sold by the seller.
2 Reference documents this specification refers to the following documents.
JJF 1261.1-2017 Energy efficiency measurement and testing rules for energy-using products GB/T 2829-2002 Periodic Inspection Attribute Sampling Procedure and Table (Applicable to the Inspection of Process Stability) GB/T 17758-2010 Unit type air conditioner GB/T 18837-2002 Multi-connected air conditioning (heat pump) unit GB 21454-2008 Multi-connected air conditioning (heat pump) unit energy efficiency limit value and energy efficiency grade GB 27941-2011 Application design and installation requirements for multi-unit air conditioning (heat pump) units for dated reference documents, only the dated version applies to this specification; for undated reference documents, the latest version (including all amendments) is applicable to this specification.
3 Terms and units of measurement the following terms and measurement units apply to this specification.
3.1 Cooling capacity Under the specified refrigeration capacity test conditions, the unit of measurement is W for the heat exhausted from enclosed spaces, rooms or areas on multiple lines.
3.2 Cooling power consumption Under the specified refrigeration capacity test conditions, the total power consumed during multi-line operation is measured in W.
3.3 Refrigeration energy efficiency ratio Under the specified refrigeration capacity test conditions, the ratio of multi-line refrigeration capacity to refrigeration power consumption is measured in W/W.
3.4 Refrigeration comprehensive performance coefficient A test and calculated according to the method described in Appendix B, describing the value of multi-line part-load cooling efficiency, the unit of measurement is W/W.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 27 pages — is available in the English PDF.
How to Download JJF 1770-2019
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Fast delivery
After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
JJF 2425-2026 — Calibration specification for carbon dioxide incubators
JJF 1183-2025 — Calibration Specification for Temperature Transmitters
JJF 1282-2025 — Calibration Specification for Time Delay Relays
JJF 1770-2019