National Standard of the People's Republic of China
- ICS
- 17.180
Contents
- Introduction (II)
- 1 Scope (1)
- 2 Reference documents (1)
- 3 Term (1)
- 4 Overview (1)
- 5 Legal management requirements (2)
- 5.1 Unit of measurement (2)
- 5.2 Requirements for the marking of measurement legal system and the marking of measuring instruments (2)
- 6 Measurement requirements (2)
- 6.1 Spectral response and band division (2)
- 6.2 Zero error (3)
- 6.3 Long wave response error (3)
- 6.4 Cosine characteristic (directional response) error(3)
- 6.5 Linearity error(3)
- 6.6 Shift error (3)
- 6.7 Fatigue error(4)
- 6.8 Maximum allowable relative indication error (4)
- 7 General technical requirements (4)
- 7.1 Appearance and structure (4)
- 7.2 Electrical safety(4)
- 7.3 Environmental adaptability (5)
- 8 Type evaluation item list (5)
- 9 Provide the number of prototypes and how to use the prototypes (6)
- 9.1 Number of prototypes provided (6)
- 9.2 How to use the prototype (7)
- 10 Test methods and conditions of test items, data processing and qualification criteria (7)
- 10.1 Measurement requirements(7)
- 10.2 General technical requirements (14)
- 11 List of measuring instruments and equipment used in test items (20)
- 12 Problems that should be paid attention to in type evaluation (21)
- 13 Judgment of type evaluation results (22)
- 14 Type evaluation original record format (22)
- Appendix A Original Record Format of Type Evaluation of Ultraviolet Irradiance Meter (23)
1 Scope (1)
2 Reference documents (1)
3 Term (1)
4 Overview (1)
5 Legal management requirements (2)
5.1 Unit of measurement (2)
5.2 Requirements for the marking of measurement legal system and the marking of measuring instruments (2)
6 Measurement requirements (2)
6.1 Spectral response and band division (2)
6.2 Zero error (3)
6.3 Long wave response error (3)
6.4 Cosine characteristic (directional response) error(3)
6.5 Linearity error(3)
6.6 Shift error (3)
6.7 Fatigue error(4)
6.8 Maximum allowable relative indication error (4)
7 General technical requirements (4)
7.1 Appearance and structure (4)
7.2 Electrical safety(4)
7.3 Environmental adaptability (5)
8 Type evaluation item list (5)
9 Provide the number of prototypes and how to use the prototypes (6)
9.1 Number of prototypes provided (6)
9.2 How to use the prototype (7)
10 Test methods and conditions of test items, data processing and qualification criteria (7)
10.1 Measurement requirements(7)
10.2 General technical requirements (14)
11 List of measuring instruments and equipment used in test items (20)
12 Problems that should be paid attention to in type evaluation (21)
13 Judgment of type evaluation results (22)
14 Type evaluation original record format (22)
Appendix A Original Record Format of Type Evaluation of Ultraviolet Irradiance Meter (23)
Introduction
This type evaluation outline is based on JJF 1015-2014 "General Specification for Type Evaluation of Measuring Instruments" and JJF 1016-the 2014 "Guidelines for the Compilation of the Type Evaluation Outline for Measuring Instruments" was prepared as a basic specification.
The technical indicators of this type evaluation outline refer to the verification regulations of JJG879-2015 "Ultraviolet Irradiance Meter".
This type evaluation outline is released for the first time.
Type Evaluation Outline of Ultraviolet Irradiance Meter
1 Scope
This type evaluation outline is applicable to UV-A, UV-B, UV-C, UV-A1, UV-365, UV-310, UV-Type evaluation of 254-band ultraviolet illuminance meter.
2 Reference documents this specification refers to the following documents.
JJG755-2015 UV radiation illuminance working standard device verification regulation JJG879-2015 UV radiation illuminance meter verification regulations JJF 1032-2005 Terms and definitions of optical radiation measurement GB 4793.1 Safety requirements for electrical equipment for measurement, control and laboratory use Part 1: General requirements GB/T 11606-2007 Environmental test methods for analytical instruments GB/T 12085.2-2010 Optical and optical instrument environmental test method Part 2: Low temperature, high temperature, Damp heat for dated reference documents, only the dated version applies to this specification; for undated references the latest version (including all amendments) is applicable to this specification.
3 term
3.1 Long-wavelength range response characteristics long-wavelengthrangeresponsecharacteristics Describe the long-wavelength spectral response characteristics of the ultraviolet radiometer outside the spectral response wavelength range.
3.2 cosine (directional response) characteristics cosine (directional response) characteristics Describe the response characteristics of the ultraviolet illuminance meter when the angle of the incident light deviates from the normal incidence (the law of cosine).
4 overview
The International Commission on Illumination (CIE) divides ultraviolet radiation into UV-A (315nm~400nm), UV-B (280nm~315nm) and UV-C (100nm~280nm) three bands. Since 100nm~200nm Ultraviolet radiation is strongly absorbed in the air, so for the UV-C band, this outline only considers.200nm~280nm the test in the wavelength range is suitable for the measurement of the UV-C band in the air, but not for the measurement in the vacuum.
Figure 1 Schematic diagram of the general composition structure of the UV illuminance meter detector
Comply with ultraviolet radiation UV-A, UV-B, UV-C, UV-A1, UV-365, UV-310, UV-254 bands
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 25 pages — is available in the English PDF.
How to Download JJF 1765-2019
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Fast delivery
After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
JJF 2425-2026 — Calibration specification for carbon dioxide incubators
JJF 1183-2025 — Calibration Specification for Temperature Transmitters
JJF 1282-2025 — Calibration Specification for Time Delay Relays
JJF 1765-2019
$455.00