JJF 1761-2019Calibration Specification for Selective Level Meters (English PDF)
选频电平表校准规范
This is a limited preview
Buy now to download the full PDF (28 pages)
Need quotation for your management?
Get a formal quotation for JJF 1761-2019 in 30 minutes.
Issued by
State Administration for Market Regulation
Level / Type
National · Mandatory
Issue date
January 1, 2019
Implementation date
March 27, 2020
Scope
JJF 1761-2019 is the English-translated version of 选频电平表校准规范.
JJF 1761-2019 is the Chinese standard "Calibration Specification for Selective Level Meters".
Found what you need?
Document preview — JJF 1761-2019
National Standard of the People's Republic of China
- ICS
- 17.220
Contents
- Introduction (II)
- 1 Scope (1)
- 2 Overview (1)
- 3 Measurement characteristics (1)
- 3.1 Level measurement (1)
- 3.2 Frequency measurement (1)
- 3.3 Frequency selection bandwidth (2)
- 3.4 Selectivity (stop band attenuation) (2)
- 3.5 IF suppression (2)
- 3.6 Image suppression (2)
- 3.7 Intrinsic distortion (2)
- 3.8 Combined interference in the aircraft (2)
- 3.9 Noise floor (2)
- 3.10 Input balance (input longitudinal interference) (2)
- 3.11 Return loss (2)
- 4 Calibration conditions (2)
- 4.1 Environmental conditions (2)
- 4.2 Measurement standards and other equipment (2)
- 5 Calibration items and calibration methods (4)
- 5.1 Calibration items (4)
- 5.2 Calibration method (4)
- 6 Expression of calibration results (13)
- 7 Recalibration time interval (13)
- Appendix A Original Record Format (14)
- Appendix B. Internal page format of the calibration certificate (21)
- Appendix C Examples of Uncertainty Evaluation of Calibration for Major Projects (28)
1 Scope (1)
2 Overview (1)
3 Measurement characteristics (1)
3.1 Level measurement (1)
3.2 Frequency measurement (1)
3.3 Frequency selection bandwidth (2)
3.4 Selectivity (stop band attenuation) (2)
3.5 IF suppression (2)
3.6 Image suppression (2)
3.7 Intrinsic distortion (2)
3.8 Combined interference in the aircraft (2)
3.9 Noise floor (2)
3.10 Input balance (input longitudinal interference) (2)
3.11 Return loss (2)
4 Calibration conditions (2)
4.1 Environmental conditions (2)
4.2 Measurement standards and other equipment (2)
5 Calibration items and calibration methods (4)
5.1 Calibration items (4)
5.2 Calibration method (4)
6 Expression of calibration results (13)
7 Recalibration time interval (13)
Appendix A Original Record Format (14)
Appendix B. Internal page format of the calibration certificate (21)
Appendix C Examples of Uncertainty Evaluation of Calibration for Major Projects (28)
Introduction
This specification is based on JJF 1071-2010 "Rules for Compiling National Measurement and Calibration Specifications" and JJF 1059.1-2012 Compilation of "Measurement Uncertainty Evaluation and Representation".
This specification is revised based on JJG777-1992 "Frequency Selection Level Meter", compared with JJG777-1992, in addition to editorial changes, the main technical changes in this specification are as follows.
--- The upper frequency limit is increased from 30MHz to 150MHz;
--- standardized the name of the calibration project;
--- According to the different level display methods, the corresponding technical indicators and calibration methods are refined;
--- Added the calibration method for unbalanced input level measurement under different nominal input impedances;
--- Modify the calibration method of frequency measurement;
--- Modify the calibration method of 0dBm level;
--- Modified the calibration method of the meter scale;
--- Modify the attenuation calibration method;
--- Modify the calibration method of return loss;
--- Modify the calibration method of input balance (input longitudinal interference);
--- Decompose the original selective measurement index into two indexes. frequency selection bandwidth and selectivity (stop band attenuation).
--- Appendix C gives an example of the uncertainty assessment method for level measurement.
Previous releases of this specification.
--- JJG777-1992.
Calibration Specification for Frequency Selective Level Meter
1 Scope
This specification applies to the calibration of frequency selective level meters with an upper frequency limit of 150MHz. The receiving part of the transmission tester the calibration can be performed by reference.
2 Overview
The frequency selection level meter is constructed according to the principle of superheterodyne, which realizes the level measurement within the selected bandwidth and has the level measurement standard Features such as high accuracy and wide level measurement range. Frequency selection level meter can be divided into pointer type frequency selection level meter and digital indication selection Frequency level meter, frequency selection level meter has two measurement functions of broadband and frequency selection, usually the input port has balanced input and unbalanced Enter two types.
Frequency selection level meters are mainly used for the manufacture, installation, maintenance and testing of communication equipment, and the transmission of high-frequency signals in power systems.
It is widely used in level measurement in scientific research and production.
3 Measurement characteristics
3.1 Level measurement
3.1.1 Digital indication frequency selection level meter Measuring range. -110dBm ~ 20dBm (input impedance 75ohm);
Maximum allowable error. ± (0.15 ~ 2.0) dB.
3.1.2 Pointer frequency selection level meter
a) Zero level (0dBm) Basic error. ± (0.1 ~ 0.2) dB (reference frequency 1kHz);
Frequency response. ± (0.2 ~ 0.5) dB.
b) attenuation
Range. (0 ~ 70) dB;
Basic error. ± 0.2dB (reference frequency 1kHz);
Frequency response. ± (0.2 ~ 0.5) dB.
c) Head scale
Range. (-20 ~ 10) dBm;
Maximum allowable error. ± (0.2 ~ 0.5) dB.
3.2 Frequency measurement
3.2.1 Balanced input Frequency range. 20Hz ~ 2MHz;
Maximum allowable error. ± (1 × 10-3 ~ 1 × 10-6).
3.2.2 Unbalanced input Frequency range. 20Hz ~ 150MHz;
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 28 pages — is available in the English PDF.
How to Download JJF 1761-2019
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Fast delivery
After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
JJF 2425-2026 — Calibration specification for carbon dioxide incubators
JJF 1183-2025 — Calibration Specification for Temperature Transmitters
JJF 1282-2025 — Calibration Specification for Time Delay Relays
JJF 1761-2019
$700.00