JJF 1759-2019Calibration Specification for Attenuation Calibrators (English PDF)
衰减校准装置校准规范
This is a limited preview
Buy now to download the full PDF (11 pages)
Need quotation for your management?
Get a formal quotation for JJF 1759-2019 in 30 minutes.
Issued by
State Administration for Market Regulation
Level / Type
National · Mandatory
Issue date
January 1, 2019
Implementation date
March 27, 2020
Scope
JJF 1759-2019 is the English-translated version of 衰减校准装置校准规范.
JJF 1759-2019 is the Chinese standard "Calibration Specification for Attenuation Calibrators".
Found what you need?
Document preview — JJF 1759-2019
National Standard of the People's Republic of China
- ICS
- 17.220
Contents
- Introduction (II)
- 1 Scope (1)
- 2 Overview (1)
- 3 Measurement characteristics (1)
- 4 Calibration conditions (1)
- 5 Calibration items and calibration methods (2)
- 5.1 Calibration items (2)
- 5.2 Calibration method (2)
- 6 Expression of calibration results (2)
- 7 Recalibration time interval (3)
- Appendix A Original Record Format (4)
- Appendix B. Internal page format of the calibration certificate (5)
- Appendix C Examples of Uncertainty Evaluation of Calibration Results of Main Items (6)
1 Scope (1)
2 Overview (1)
3 Measurement characteristics (1)
4 Calibration conditions (1)
5 Calibration items and calibration methods (2)
5.1 Calibration items (2)
5.2 Calibration method (2)
6 Expression of calibration results (2)
7 Recalibration time interval (3)
Appendix A Original Record Format (4)
Appendix B. Internal page format of the calibration certificate (5)
Appendix C Examples of Uncertainty Evaluation of Calibration Results of Main Items (6)
Introduction
This specification is based on JJF 1071-2010 "Rules for Compiling National Measurement and Calibration Specifications" and JJF 1059.1-2012 Compilation of "Measurement Uncertainty Evaluation and Representation". This specification is for JJG424-1986 "TO7 (TO7A) type attenuation the main changes in the revision of the Calibration Regulations for Calibration Devices are as follows.
--- The scope of application of the original regulations was revised, and the original only applies to TO7 (TO7A), TO6, VM-3 it is adapted to the current general attenuation calibration device, and the name of the specification is changed to "Attenuation Calibration Device Calibration Specification";
--- The frequency range of the original regulations has been extended;
--- The range of standard instruments used for verification in the original regulations was changed.
The previous releases of this specification are.
--- JJG424-1986.
Calibration specifications for attenuation calibration devices
1 Scope
This specification applies to the calibration of attenuation calibration devices in the frequency range of 100kHz to 50GHz.
2 Overview
There are many types of attenuation calibration devices, and their measurement principles mainly use alternative methods and measurement receiver methods, Now the measurement of attenuation. Attenuation calibration device is a commonly used equipment in radio measurement, used to measure various types of attenuation Minus.
3 Measurement characteristics
a) Attenuation. 0dB ~ 100dB (100kHz ~ 18GHz); 0dB ~ 80dB (18GHz ~ 50GHz);
b) Maximum allowable error. ± (0.02dB 0.002 × A) (A. 0dB ~ 80dB); ± 0.30dB (90dB), ± 0.40dB (100dB).
4 Calibration conditions
4.1 Environmental conditions
a) Ambient temperature. 23 °C ± 5 °C;
b) Relative humidity. <=80%;
c) Power requirements. 220V ± 11V, 50Hz ± 1Hz;
d) Others. There are no electromagnetic interference and mechanical vibrations that affect the normal operation of the instrument.
4.2 Calibration equipment
4.2.1 Standard attenuator
a) Frequency range. 100kHz ~ 50GHz;
b) Attenuation. 0dB ~ 100dB (100kHz ~ 18GHz), 0dB ~ 80dB (18GHz ~ 50GHz);
c) Uncertainty. 0.01dB ~ 0.13dB (k = 2).
4.2.2 Signal generator
a) Frequency range. 100kHz ~ 50GHz;
b) Level range. -40dBm ~ 10dBm;
With time base input and output functions.
4.2.3 Fixed attenuator
a) Frequency range. 100kHz ~ 50GHz;
b) Attenuation. 6dB/10dB;
c) Voltage standing wave ratio. <=1.1 (100kHz ~ 18GHz); <=1.2 (18GHz ~ 40GHz); <=1.25
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 11 pages — is available in the English PDF.
How to Download JJF 1759-2019
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Fast delivery
After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
JJF 2425-2026 — Calibration specification for carbon dioxide incubators
JJF 1183-2025 — Calibration Specification for Temperature Transmitters
JJF 1282-2025 — Calibration Specification for Time Delay Relays
JJF 1759-2019