JJF 1758-2019Calibration Specification for Low Frequency Phase Shifters and Phase Generators (English PDF)
低频移相器及相位发生器校准规范低频移相器及相位发生器校准规范
This is a limited preview
Buy now to download the full PDF (12 pages)
Need quotation for your management?
Get a formal quotation for JJF 1758-2019 in 30 minutes.
Issued by
State Administration for Market Regulation
Level / Type
National · Mandatory
Issue date
January 1, 2019
Implementation date
March 27, 2020
Scope
JJF 1758-2019 is the English-translated version of 低频移相器及相位发生器校准规范低频移相器及相位发生器校准规范.
JJF 1758-2019 is the Chinese standard "Calibration Specification for Low Frequency Phase Shifters and Phase Generators".
Found what you need?
Document preview — JJF 1758-2019
National Standard of the People's Republic of China
- ICS
- 17.220
Contents
- Introduction (II)
- 1 Scope (1)
- 2 Overview (1)
- 3 Measurement characteristics (1)
- 3.1 Output frequency (1)
- 3.2 Output sine wave amplitude (1)
- 3.3 Total harmonic distortion of output sine wave (1)
- 3.4 Output phase shift (1)
- 4 Calibration conditions (1)
- 4.1 Environmental conditions (1)
- 4.2 Measurement standards and other equipment (1)
- 5 Calibration items and calibration methods (2)
- 5.1 Calibration items (2)
- 5.2 Appearance and functional inspection (3)
- 5.3 Output frequency (3)
- 5.4 Output sine wave amplitude (3)
- 5.5 Output sine wave total harmonic distortion (3)
- 5.6 Output phase shift (4)
- 6 Expression of calibration results (6)
- 7 Recalibration time interval (6)
- Appendix A Original Record Format (7)
- Appendix B. Internal page format of the calibration certificate (9)
- Appendix C Examples of Uncertainty Evaluation of Calibration Results of Main Items (11)
1 Scope (1)
2 Overview (1)
3 Measurement characteristics (1)
3.1 Output frequency (1)
3.2 Output sine wave amplitude (1)
3.3 Total harmonic distortion of output sine wave (1)
3.4 Output phase shift (1)
4 Calibration conditions (1)
4.1 Environmental conditions (1)
4.2 Measurement standards and other equipment (1)
5 Calibration items and calibration methods (2)
5.1 Calibration items (2)
5.2 Appearance and functional inspection (3)
5.3 Output frequency (3)
5.4 Output sine wave amplitude (3)
5.5 Output sine wave total harmonic distortion (3)
5.6 Output phase shift (4)
6 Expression of calibration results (6)
7 Recalibration time interval (6)
Appendix A Original Record Format (7)
Appendix B. Internal page format of the calibration certificate (9)
Appendix C Examples of Uncertainty Evaluation of Calibration Results of Main Items (11)
Introduction
This specification is based on JJF 1071-2010 "Rules for Compiling National Measurement and Calibration Specifications" and JJF 1059.1-2012 Compilation of "Measurement Uncertainty Evaluation and Representation".
This specification is a revision of JJG530-88 "Regulations for Verification of Low Frequency Phase Shifters (Trial)" as follows.
--- The name of the original regulation was "Verification Regulation of Low Frequency Phase Shifter (Trial)", which is now revised to "Low Frequency Phase Shifter and Phase Calibration Specification of Bit Generator ";
--- Added the calibration of the phase generator, the calibration items include output frequency, output sine wave amplitude, output positive Sine wave total harmonic distortion and output phase shift;
--- The frequency range is extended from 50Hz ~ 50kHz to 1Hz ~ 100kHz.
Previous releases of this specification.
--- JJG530-1988.
Calibration specification for low frequency phase shifter and phase generator
1 Scope
This specification applies to the calibration of low-frequency phase shifters and phase generators with frequencies in the range of 1 Hz to 100 kHz.
2 Overview
The low-frequency phase shifter makes the output signal have a certain phase difference with respect to the input signal through the phase-shift network.
As a dual-channel signal generator, the phase generator can simultaneously output two channels of the same frequency with precisely adjustable phase difference Signal, and the output amplitude of each channel can be adjusted independently.
Low-frequency phase shifters and phase generators are mainly used in automatic control systems, radio navigation ranging and positioning systems, and it can be used as a phase standard to calibrate phase measurement equipment such as frequency response analyzers and low-frequency phase meters.
3 Measurement characteristics
3.1 Output frequency Frequency range. 1Hz ~ 100kHz;
Maximum allowable error. ± 1 × 10-4.
3.2 Output sine wave amplitude Amplitude range. 50mV ~ 10V;
Maximum allowable error. ± (0.5% ~ 2%) (10Hz ~ 100kHz).
3.3 Total harmonic distortion of output sine wave Range. 0.01% ~ 0.3%.
3.4 Output phase shift Frequency range. 1Hz ~ 100kHz;
Phase shift range. 0 ° ~ 360 °;
Maximum allowable error. ± (0.02 ° ~ 0.2 °) (low-frequency phase shifter);
± (0.01 ° ~ 0.5 °) (phase generator).
Note. The above technical indicators are not used to determine eligibility, only for reference.
4 Calibration conditions
4.1 Environmental conditions
a) Ambient temperature. 23 °C ± 5 °C;
b) Relative humidity. <=80%;
c) Power requirements. voltage (220V ± 11V), frequency (50Hz ± 1Hz);
d) Others. There are no mechanical vibrations and electromagnetic interference that affect the normal operation of the instrument.
4.2 Measurement standards and other equipment
4.2.1 General counter
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 12 pages — is available in the English PDF.
How to Download JJF 1758-2019
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Fast delivery
After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
JJF 2425-2026 — Calibration specification for carbon dioxide incubators
JJF 1183-2025 — Calibration Specification for Temperature Transmitters
JJF 1282-2025 — Calibration Specification for Time Delay Relays
JJF 1758-2019
$325.00