JJF 1753-2019Calibration Specification for Medical Pressure Pulse Lithotripsy Machines (English PDF)

医用体外压力脉冲碎石机校准规范

Preview PDF

This is a limited preview

Buy now to download the full PDF (11 pages)

Need quotation for your management?

Get a formal quotation for JJF 1753-2019 in 30 minutes.

Issued by

State Administration for Market Regulation

Level / Type

National · Mandatory

Issue date

January 1, 2019

Implementation date

December 27, 2019

Scope

JJF 1753-2019 is the English-translated version of 医用体外压力脉冲碎石机校准规范.

JJF 1753-2019 is the Chinese standard "Calibration Specification for Medical Pressure Pulse Lithotripsy Machines".

Found what you need?

Document preview — JJF 1753-2019

National Standard of the People's Republic of China

ICS
17.140

Contents

  • Introduction (III)
  • 1 Scope (1)
  • 2 References (1)
  • 3 Terms and units of measurement (1)
  • 3.1 Gravel (1)
  • 3.2 Pressure pulse (1)
  • 3.3 Focus (1)
  • 3.4 Focal volume (1)
  • 3.5 Maximum focal length (1)
  • 3.6 Pulse width of positive sound pressure (1)
  • 3.7 Pressure pulse rise time (1)
  • 3.8 Pressure pulse generator (1)
  • 3.9 Minimum displacement of positioning device (2)
  • 4 Overview (2)
  • 5 Metrological characteristics (2)
  • 5.1 Peak sound pressure (2)
  • 5.2 Repeatability of peak sound pressure output (2)
  • 5.3 Pulse width of positive sound pressure (2)
  • 5.4 Rise time of pressure pulse (2)
  • 5.5 Geometrical dimensions of the focal area (2)
  • 5.6 Distance from focus to generator end face (2)
  • 5.7 Deviation of focus and target mark (2)
  • 5.8 Minimum displacement of positioning device (3)
  • 6 Calibration conditions (3)
  • 6.1 Environmental conditions (3)
  • 6.2 Calibration equipment (3)
  • 7 Calibration items and calibration methods (3)
  • 7.1 Preparations before calibration (3)
  • 7.2 Peak sound pressure (3)
  • 7.3 Peak sound pressure output repeatability (5)
  • 7.4 Pulse width of positive sound pressure (5)
  • 7.5 Pressure pulse rise time (5)
  • 7.6 Geometry of the focal area (5)
  • 7.7 Distance from focus to generator end face (5)
  • 7.8 Deviation of focus and target mark (5)
  • 7.9 Minimum displacement of positioning device (5)
  • 8 Expression of calibration results (6)
  • 8.1 Calibration records (6)
  • 8.2 Calibration certificate (6)
  • 8.3 Measurement uncertainty of calibration results (6)
  • 9 Recalibration interval (6)
  • Appendix A Internal Page Format of Calibration Certificate for Medical Extracorporeal Pressure Pulse Lithotripter (7)
  • Appendix B Example of measurement uncertainty evaluation of medical extracorporeal pressure pulse lithotripter (8)

1 Scope (1)

2 References (1)

3 Terms and units of measurement (1)

3.1 Gravel (1)

3.2 Pressure pulse (1)

3.3 Focus (1)

3.4 Focal volume (1)

3.5 Maximum focal length (1)

3.6 Pulse width of positive sound pressure (1)

3.7 Pressure pulse rise time (1)

3.8 Pressure pulse generator (1)

3.9 Minimum displacement of positioning device (2)

4 Overview (2)

5 Metrological characteristics (2)

5.1 Peak sound pressure (2)

5.2 Repeatability of peak sound pressure output (2)

5.3 Pulse width of positive sound pressure (2)

5.4 Rise time of pressure pulse (2)

5.5 Geometrical dimensions of the focal area (2)

5.6 Distance from focus to generator end face (2)

5.7 Deviation of focus and target mark (2)

5.8 Minimum displacement of positioning device (3)

6 Calibration conditions (3)

6.1 Environmental conditions (3)

6.2 Calibration equipment (3)

7 Calibration items and calibration methods (3)

7.1 Preparations before calibration (3)

7.2 Peak sound pressure (3)

7.3 Peak sound pressure output repeatability (5)

7.4 Pulse width of positive sound pressure (5)

7.5 Pressure pulse rise time (5)

7.6 Geometry of the focal area (5)

7.7 Distance from focus to generator end face (5)

7.8 Deviation of focus and target mark (5)

7.9 Minimum displacement of positioning device (5)

8 Expression of calibration results (6)

8.1 Calibration records (6)

8.2 Calibration certificate (6)

8.3 Measurement uncertainty of calibration results (6)

9 Recalibration interval (6)

Appendix A Internal Page Format of Calibration Certificate for Medical Extracorporeal Pressure Pulse Lithotripter (7)

Appendix B Example of measurement uncertainty evaluation of medical extracorporeal pressure pulse lithotripter (8)

Introduction

This specification is based on the rules and format given in JJF 1071-2010 "Rules for Compiling National Measurement and Calibration Specifications" prepared by.

The standard reference GB/T 16407-2006 "Acoustic medical external pressure pulse lithotripter sound field characteristics and measurement Volume ", GB 9706.22-2003" Medical Electrical Equipment Part 2. Safety Requirements for In Vitro Lithotripsy Equipment " Requirement and other relevant domestic and foreign standards are formulated.

This specification is the first release.

Calibration specification for medical extracorporeal pressure pulse lithotripter

1 Scope

This specification applies to the calibration of electromagnetic medical external pressure pulse lithotripters.

Hydroelectric and piezoelectric medical extracorporeal pressure pulse lithotripters can be implemented with reference to this specification.

2 Reference documents this specification refers to the following documents.

JJF 1001-2011 General Measurement Terms and Definitions JJF 1034-2005 Acoustic measurement terms and definitions GB 3102.7-1993 Acoustic quantities and units GB 9706.1-2007 Medical electrical equipment Part 1. General requirements for safety GB 9706.22-2003 Medical electrical equipment Part 2. Particular requirements for the safety of in vitro lithotripsy equipment GB/T 16407-2006 Acoustic medical external pressure pulse lithotripter sound field characteristics and measurement YY0001-2008 Technical requirements for in vitro lithotripsy equipment for dated reference documents, only the dated version applies to this specification; for those without date references the latest version (including all amendments) is applicable to this specification.

3 Terms and units of measurement

3.1 Lithotripsy

Crushing or breaking of human stones.

3.2 Pressure pulse Sound pressure pulses generated by medical lithotripters.

3.3 focus

In the pressure pulse sound field, the position of the maximum positive peak sound pressure.

3.4 Focal volume

The volume of the space enclosed by the interface 6dB lower than the maximum positive peak sound pressure (0dB) around the focal point.

3.5 Maximum focal width in the (x, y) plane containing the focal point, the maximum sound pressure line around the focal point is 6dB lower than the maximum positive peak sound pressure.

Large width.

3.6 Width of positive sound pressure pulse widthofpressurepulse Before and after the peak value of the sound pressure pulse, the sound pressure value is equal to the time difference between the two instantaneous sound pressures of 50% of the peak value of the pulse, in units for seconds (s).

3.7 Rise time of pressure pulse the time from 10% of the positive peak of the pressure pulse to 90%, in seconds (s).

3.8 Pressure pulse generator generatorofpressurepulse

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 11 pages — is available in the English PDF.

How to Download JJF 1753-2019

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Fast delivery

    After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
11 pages
Fast delivery
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

JJF 1753-2019

$285.00