JJF 1752-2019Calibration Specification for Automatic Closed Luminescence Immunoassay Analyzers (English PDF)
全自动封闭型发光免疫分析仪校准规范
This is a limited preview
Buy now to download the full PDF (10 pages)
Need quotation for your management?
Get a formal quotation for JJF 1752-2019 in 30 minutes.
Issued by
State Administration for Market Regulation
Level / Type
National · Mandatory
Issue date
January 1, 2019
Implementation date
December 27, 2019
Scope
JJF 1752-2019 is the English-translated version of 全自动封闭型发光免疫分析仪校准规范.
JJF 1752-2019 is the Chinese standard "Calibration Specification for Automatic Closed Luminescence Immunoassay Analyzers".
Found what you need?
Document preview — JJF 1752-2019
National Standard of the People's Republic of China
- ICS
- 17.020
Contents
- Introduction (II)
- 1 Scope (1)
- 2 References (1)
- 3 Overview (1)
- 4 Measurement characteristics (1)
- 4.1 Indication error (1)
- 4.2 Repeatability (1)
- 4.3 Carrying pollution rate (2)
- 4.4 Linear (2)
- 5 Calibration conditions (2)
- 5.1 Environmental conditions (2)
- 5.2 Calibration reference materials and reagents (2)
- 6 Calibration items and calibration methods (2)
- 6.1 Indication error (2)
- 6.2 Repeatability (2)
- 6.3 Carrying pollution rate (3)
- 6.4 Linear (3)
- 7 Expression of calibration results (3)
- 8 Recalibration time interval (4)
- Appendix A Selection Principles of Calibration Standard Materials (5)
- Appendix B. Contents and Format of Calibration Record and Calibration Certificate (6)
- Appendix C Examples of Uncertainty Evaluation of Indication Error Measurement Results (9)
1 Scope (1)
2 References (1)
3 Overview (1)
4 Measurement characteristics (1)
4.1 Indication error (1)
4.2 Repeatability (1)
4.3 Carrying pollution rate (2)
4.4 Linear (2)
5 Calibration conditions (2)
5.1 Environmental conditions (2)
5.2 Calibration reference materials and reagents (2)
6 Calibration items and calibration methods (2)
6.1 Indication error (2)
6.2 Repeatability (2)
6.3 Carrying pollution rate (3)
6.4 Linear (3)
7 Expression of calibration results (3)
8 Recalibration time interval (4)
Appendix A Selection Principles of Calibration Standard Materials (5)
Appendix B. Contents and Format of Calibration Record and Calibration Certificate (6)
Appendix C Examples of Uncertainty Evaluation of Indication Error Measurement Results (9)
Introduction
In the drafting of this specification, reference was made to YY/T 1155-2019 "Automatic Luminescence Immunoassay Analyzer" JJF 1071-2010 "National Metrology Calibration Regulations Writing Rules" requirements.
This specification is the first release.
Fully automatic closed-type luminescence immunoassay analyzer Calibration specifications
1 Scope
This specification is applicable to the calibration of fully automatic enclosed luminescence immunoanalyzers based on the principles of chemiluminescence and electrochemiluminescence.
2 Reference documents this specification refers to the following documents.
JJF 1001-2011 General Measurement Terms and Definitions JJF 1059.1 Evaluation and expression of measurement uncertainty YY/T 1155-2019 Automatic luminescence immunoassay analyzer for dated reference documents, only the dated version applies to this specification; for those without date references the latest version (including all amendments) is applicable to this specification.
3 Overview
The fully-automatic closed-type luminescence immunoassay analyzer (hereinafter referred to as immunoassay analyzer) is a sample detected by immunoassay Analytical instruments for specific targets in this book. The immune analyzer is usually composed of a computer system, internal servo system, loading unit, the cleaning unit, incubation unit and detection unit are composed (see Figure 1), usually only with the kit kit provided by the manufacturer the completion detection system completes the analysis of specific targets and is closed. The immune analyzer can be completed automatically according to the set procedure the entire analysis process such as sample addition, cleaning, incubation, detection, etc., through the detection of chemiluminescence or electrochemical the luminescence signal realizes the qualitative or quantitative detection of specific targets.
Figure 1 Schematic diagram of immune analyzer
4 Metering characteristics
4.1 Indication error According to the measurement result of the reference material specified in 5.2.1, the indication error is not greater than ± 15% Technical requirements given by the supplier.
4.2 Repeatability
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 10 pages — is available in the English PDF.
How to Download JJF 1752-2019
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Fast delivery
After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
JJF 2425-2026 — Calibration specification for carbon dioxide incubators
JJF 1183-2025 — Calibration Specification for Temperature Transmitters
JJF 1282-2025 — Calibration Specification for Time Delay Relays
JJF 1752-2019