JJF 1749-2019Calibration Specification for Vehicle Contour Dimensions Testers (English PDF)
汽车外廓尺寸检测仪校准规范
This is a limited preview
Buy now to download the full PDF (11 pages)
Need quotation for your management?
Get a formal quotation for JJF 1749-2019 in 30 minutes.
Issued by
State Administration for Market Regulation
Level / Type
National · Mandatory
Issue date
January 1, 2019
Implementation date
December 27, 2019
Scope
JJF 1749-2019 is the English-translated version of 汽车外廓尺寸检测仪校准规范.
JJF 1749-2019 is the Chinese standard "Calibration Specification for Vehicle Contour Dimensions Testers".
Found what you need?
Document preview — JJF 1749-2019
National Standard of the People's Republic of China
- ICS
- 17.040
Contents
- Introduction (II)
- 1 Scope (1)
- 2 References (1)
- 3 Overview (1)
- 4 Measurement characteristics (1)
- 4.1 Indication error (1)
- 4.2 Repeatability (1)
- 5 Calibration conditions (1)
- 5.1 Environmental conditions (1)
- 5.2 Measurement standards and other equipment (1)
- 5.3 Site facilities (2)
- 6 Calibration items and calibration methods (2)
- 6.1 Calibration items (2)
- 6.2 Calibration of indication error (2)
- 6.3 Repeatability (4)
- 7 Expression of calibration results (4)
- 8 Recalibration time interval (4)
- Appendix A Calibration Records of Automobile External Dimensions Tester (5)
- Appendix B. Calibration certificate (inner page) content (6)
- Appendix C Examples of Uncertainty Evaluation of Indication Error Measurement of Automobile Exterior Dimension Detector (7)
1 Scope (1)
2 References (1)
3 Overview (1)
4 Measurement characteristics (1)
4.1 Indication error (1)
4.2 Repeatability (1)
5 Calibration conditions (1)
5.1 Environmental conditions (1)
5.2 Measurement standards and other equipment (1)
5.3 Site facilities (2)
6 Calibration items and calibration methods (2)
6.1 Calibration items (2)
6.2 Calibration of indication error (2)
6.3 Repeatability (4)
7 Expression of calibration results (4)
8 Recalibration time interval (4)
Appendix A Calibration Records of Automobile External Dimensions Tester (5)
Appendix B. Calibration certificate (inner page) content (6)
Appendix C Examples of Uncertainty Evaluation of Indication Error Measurement of Automobile Exterior Dimension Detector (7)
Introduction
This specification is based on JJF 1059.1-2012 "Measurement Uncertainty Evaluation and Expression", JJF 1071-2010 "National the requirements of the "Writing Rules for the Calibration Standards".
This specification refers to GB 1589-2016 "External Dimensions, Axle Loads and Mass Limits of Automobiles, Trailers, and Trains", GB 18565-2016 "Comprehensive performance requirements and inspection methods of road transport vehicles", GB 21861-2014 "Motor vehicles Safety technical inspection items and methods", GB/T 3730.3 "Terms and definitions of vehicles and trailers and vehicle dimensions" Formulated with GB/T 15089 "Classification of Motor Vehicles and Trailers".
This specification is the first release.
Calibration Specification of Automobile External Dimension Tester
1 Scope
This specification is applicable to the calibration of the car's external dimension detector.
2 Reference documents this specification refers to the following documents.
GB 1589-2016 Cars, trailers and car trains, external dimensions, axle loads and quality limits GB/T 3730.3 Terms and Definitions of Automobiles and Trailers GB 18565-2016 Comprehensive performance requirements and inspection methods of road transport vehicles GB 21861-2014 Motor vehicle safety technical inspection items and methods for dated reference documents, only the dated version applies to this specification; for those without date references the latest version (including all amendments) is applicable to this specification.
3 Overview
The car outline size detector (hereinafter referred to as the detector) is used to automatically measure the car outline size (length, width, High) devices generally use optical imaging, infrared or laser technology. The detector mainly includes the front-end collection system System and back-end analysis processing system.
4 Metering characteristics
4.1 Indication error According to 5.1.1.1 in GB 18565-2016 and Appendix A.1.2 in GB 21861-2014, the maximum length is Allowable error. ±0.8% or ±50mm; width and height maximum allowable error. ±0.8% or ±20mm.
4.2 Repeatability
Generally not more than 0.8%.
Note. The above indicators are not suitable for qualification judgment, and are for reference only.
5 Calibration conditions
5.1 Environmental conditions
5.1.1 Ambient temperature. -10°C~45°C;
5.1.2 Environmental relative humidity. not more than 85%.
5.1.3 Calibration should be performed in an environment free of pollution, light, vibration, electromagnetic interference, etc.
5.2 Measurement standards and other equipment See Table 1 for measurement standards and other equipment.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 11 pages — is available in the English PDF.
How to Download JJF 1749-2019
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Fast delivery
After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.