Document preview — JJF 1748-2019

National Standard of the People's Republic of China

ICS
17.020

Contents

  • Introduction (II)
  • 1 Scope (1)
  • 2 References (1)
  • 3 Terminology (1)
  • 4 Overview (1)
  • 5 Metrological characteristics (1)
  • 5.1 Depth of compression (1)
  • 5.2 Pressing frequency (1)
  • 5.3 Individual blowing frequency (1)
  • 5.4 Tidal volume (2)
  • 5.5 Maximum safety pressure of mask gas circuit (2)
  • 6 Calibration conditions (2)
  • 6.1 Environmental conditions (2)
  • 6.2 Measurement standards and other equipment (2)
  • 7 Calibration items and calibration methods (2)
  • 7.1 Appearance and functional inspection (2)
  • 7.2 Compression depth (3)
  • 7.3 Compression frequency (3)
  • 7.4 Individual blowing frequency (4)
  • 7.5 Tidal volume (5)
  • 7.6 Maximum safety pressure of mask gas circuit (5)
  • 8 Expression of calibration results (5)
  • 9 Recalibration interval (6)
  • Appendix A. Formats of original records of CPR calibration (recommended) (7)
  • Appendix B. Internal page of calibration certificate (recommended) format style (9)
  • Appendix C Example of calibration uncertainty assessment (10)

1 Scope (1)

2 References (1)

3 Terminology (1)

4 Overview (1)

5 Metrological characteristics (1)

5.1 Depth of compression (1)

5.2 Pressing frequency (1)

5.3 Individual blowing frequency (1)

5.4 Tidal volume (2)

5.5 Maximum safety pressure of mask gas circuit (2)

6 Calibration conditions (2)

6.1 Environmental conditions (2)

6.2 Measurement standards and other equipment (2)

7 Calibration items and calibration methods (2)

7.1 Appearance and functional inspection (2)

7.2 Compression depth (3)

7.3 Compression frequency (3)

7.4 Individual blowing frequency (4)

7.5 Tidal volume (5)

7.6 Maximum safety pressure of mask gas circuit (5)

8 Expression of calibration results (5)

9 Recalibration interval (6)

Appendix A. Formats of original records of CPR calibration (recommended) (7)

Appendix B. Internal page of calibration certificate (recommended) format style (9)

Appendix C Example of calibration uncertainty assessment (10)

Introduction

This specification is based on JJF 1001-2011 "General Measurement Terms and Definitions", JJF 1059.1-2012 "Measurement Definiteness Assessment and Representation", JJF 1071-2010 "National Metrology Calibration Regulations Writing Rules" requirements.

This specification refers to JJF 1234-2018 "Ventilator Calibration Specification" and "2015 American Heart Association CPR and Cardiovascular First Aid Guide (2015AmericanHeartAssociationGuidelinesUpdateforCardiop-ulmonaryResuscitationandEmergencyCardiovascularCare).

This specification is the first release.

Cardiopulmonary resuscitation machine calibration specifications

1 Scope

This specification applies to the calibration of CPR machines. The calibration of the multi-function cardiopulmonary resuscitation machine can also be implemented with reference to this specification.

2 Reference documents this specification refers to the following documents.

JJF 1234-2018 Calibration Specification for Ventilator

2015 American Heart Association Cardiopulmonary Resuscitation and Cardiovascular First Aid Guidelines (2015AmericanHeartAssociation GuidelinesUpdateforCardiopulmonaryResuscitationandEmergencyCardiovascular Care) for dated reference documents, only the dated version applies to this specification; for those without date references the latest version (including all amendments) is applicable to this specification.

3 Terminology

3.1 Cardiopulmonary resuscitation cardiopulmonaryresuscitator Equipment that replaces manpower with machinery to perform life support operations such as artificial respiration and chest compressions to achieve cardiopulmonary resuscitation, it is also commonly called CPR and CPR.

3.2 Multi-functional cardiopulmonary resuscitator in addition to the basic cardiopulmonary resuscitation function, it also has other functions, such as. continuous CPR data recording, Data download and analysis of cardiopulmonary resuscitation, synchronization of mechanical compression and defibrillation treatment, etc.

4 Overview

Cardiopulmonary resuscitation machine (hereinafter referred to as resuscitation machine) is a commonly used medical device in trains, ambulances, airplanes, emergency rooms and other places First aid equipment. The resuscitation machine can achieve artificial respiration and chest compressions, providing a high level of uninterrupted manual compression cycles and Ventilation support. The principle of the resuscitation machine is to use the reciprocating movement of the piston to achieve uninterrupted compression of the patient's thoracic cage, supplemented by Gap ventilation. Resuscitator can be divided into two types. electric resuscitation machine and pneumatic resuscitation machine.

Plugs, masks, pipes, circuit control, etc.

5 Metrological characteristics

5.1 Depth of compression (30~50)mm, the maximum allowable error is ±15%.

5.2 Pressing frequency (100~120) times/min, the maximum allowable error is ±10%.

5.3 Individual blowing frequency (10~20) times/min, the maximum allowable error is ± (10% reading 1) times/min.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 14 pages — is available in the English PDF.

How to Download JJF 1748-2019

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Fast delivery

    After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
14 pages
Fast delivery
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

JJF 1748-2019

$300.00