JJF 1747-2019Calibration specification for retroreflective coefficient measuring instrument for body reflective marking (English PDF)
车身反光标识用逆反射系数测量仪校准规范
This is a limited preview
Buy now to download the full PDF (11 pages)
Need quotation for your management?
Get a formal quotation for JJF 1747-2019 in 30 minutes.
Issued by
State Administration for Market Regulation
Level / Type
National · Mandatory
Issue date
January 1, 2019
Implementation date
December 27, 2019
Scope
JJF 1747-2019 is the English-translated version of 车身反光标识用逆反射系数测量仪校准规范.
JJF 1747-2019 is the Chinese standard "Calibration specification for retroreflective coefficient measuring instrument for body reflective marking".
Found what you need?
Document preview — JJF 1747-2019
National Standard of the People's Republic of China
- ICS
- 17.180
Contents
- Introduction (II)
- 1 Scope (1)
- 2 References (1)
- 3 Terms and units of measurement (1)
- 3.1 Retroreflection (1)
- 3.2 Reference Center (1)
- 3.3 Reference axis (1)
- 3.4 Lighting axis (2)
- 3.5 Observation axis (2)
- 3.6 Angle of incidence beta (2)
- 3.7 Observation angle alpha (2)
- 3.8 Luminous intensity coefficient R (2)
- 3.9 Retroreflection coefficient R' (2)
- 4 Overview (2)
- 5 Metrological characteristics (2)
- 5.1 Indication error (2)
- 6 Calibration conditions (3)
- 6.1 Environmental conditions (3)
- 6.2 Measurement standards and other equipment (3)
- 7 Calibration items and calibration methods (3)
- 7.1 Calibration items (3)
- 7.2 Indication error calibration method (3)
- 8 Expression of calibration results (4)
- 8.1 Calibration data processing (4)
- 8.2 Calibration certificate (4)
- 8.3 Examples of uncertainty assessment of calibration results (4)
- 9 Recalibration time interval (5)
- Appendix A Calibration Record of Retroreflectance Coefficient Measuring Instrument for Body Reflective Marking (Recommended Format) (6)
- Appendix B. Calibration certificate content of calibration results (7)
- Appendix C Example of Uncertainty Evaluation of Indication Error Calibration of Retroreflectance Coefficient Measuring Instrument for Body Reflective Marking (9)
1 Scope (1)
2 References (1)
3 Terms and units of measurement (1)
3.1 Retroreflection (1)
3.2 Reference Center (1)
3.3 Reference axis (1)
3.4 Lighting axis (2)
3.5 Observation axis (2)
3.6 Angle of incidence beta (2)
3.7 Observation angle alpha (2)
3.8 Luminous intensity coefficient R (2)
3.9 Retroreflection coefficient R' (2)
4 Overview (2)
5 Metrological characteristics (2)
5.1 Indication error (2)
6 Calibration conditions (3)
6.1 Environmental conditions (3)
6.2 Measurement standards and other equipment (3)
7 Calibration items and calibration methods (3)
7.1 Calibration items (3)
7.2 Indication error calibration method (3)
8 Expression of calibration results (4)
8.1 Calibration data processing (4)
8.2 Calibration certificate (4)
8.3 Examples of uncertainty assessment of calibration results (4)
9 Recalibration time interval (5)
Appendix A Calibration Record of Retroreflectance Coefficient Measuring Instrument for Body Reflective Marking (Recommended Format) (6)
Appendix B. Calibration certificate content of calibration results (7)
Appendix C Example of Uncertainty Evaluation of Indication Error Calibration of Retroreflectance Coefficient Measuring Instrument for Body Reflective Marking (9)
Introduction
This specification is based on JJF 1001-2011 "General Measurement Terms and Definitions", JJF 1059.1-2012 "Measurement "Basic series of specifications for the assessment and representation of certainty", JJF 1071-2010 "Rules for Compiling National Measurement and Calibration Specifications" Make it.
This specification is mainly compiled with reference to GB/T 26377-2010 "Retroreflective Measuring Instrument".
This specification is the first release.
Calibration specification for retroreflective coefficient measuring instrument for body reflective marking
1 Scope
This specification is applicable to the calibration of the retroreflective coefficient measuring instrument for body reflective marking.
2 Reference documents this specification refers to the following documents.
JJF 1546-2015 Calibration Standard for Retroreflective Standard Board GB/T 26377-2010 retroreflective measuring instrument for dated reference documents, only the dated version applies to this specification; for those without date references the latest version (including all amendments) is applicable to this specification.
3 Terms and units of measurement JJF 1546-2015 "Reference Standard Calibration Standard", GB/T 26377-2010 "Retroreflective Measuring Instrument" the terms and definitions defined in and below apply to this specification.
3.1 Retroreflection
The reflected light returns from the direction close to the incident light and returns toward the light source (see Figure 1).
[GB/T 26377-2010, definition 3.1]
Figure 1 Retroreflective system terminology and optical test principle
3.2 Reference Center when determining the characteristics of retroreflective materials, a point given at or near the center of the sample.
[GB/T 26377-2010, definition 3.2] 3.3 reference axis it starts at the reference center and is perpendicular to the reflection line of the tested sample.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 11 pages — is available in the English PDF.
How to Download JJF 1747-2019
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Fast delivery
After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
JJF 2425-2026 — Calibration specification for carbon dioxide incubators
JJF 1183-2025 — Calibration Specification for Temperature Transmitters
JJF 1282-2025 — Calibration Specification for Time Delay Relays
JJF 1747-2019
$225.00