JJF 1710-2018Calibration Specification for Frequency Response Analyzers (English PDF)
This is a limited preview
Buy now to download the full PDF (25 pages)
Need quotation for your management?
Get a formal quotation for JJF 1710-2018 in 30 minutes.
Issued by
State Administration for Market Regulation
Level / Type
National · Mandatory
Issue date
June 25, 2018
Implementation date
September 25, 2018
Scope
JJF 1710-2018 (Calibration Specification for Frequency Response Analyzers) is available as an English-translated PDF.
JJF 1710-2018 — This standard applies to the calibration of frequency response analyzers with a frequency range below 50 MHz. Calibration of other instruments of the same type can be referred to for execution.
Found what you need?
Document preview — JJF 1710-2018
National Standard of the People's Republic of China
- ICS
- 17.220
- Classification
- A 56
Issued by: State Administration for Market Regulation
Contents
- Introduction (III)
- 1 Scope (1)
- 2 Overview (1)
- 3 Measurement characteristics (1)
- 3.1 Source output frequency (1)
- 3.2 Source output sine wave amplitude (1)
- 3.3 Source output sine wave distortion (total harmonic distortion) (1)
- 3.4 Source Output DC Offset (1)
- 3.5 Input resistance (1)
- 3.6 Single channel amplitude (1)
- 3.7 Single Channel Phase (2)
- 3.8 Channel Consistency (2)
- 3.9 Amplitude ratio between channels (2)
- 3.10 Phase difference between channels (2)
- 3.11 Common mode rejection ratio (2)
- 3.12 Channel isolation (2)
- 4 Calibration conditions (2)
- 4.1 Environmental conditions (2)
- 4.2 Measurement standards and other equipment (2)
- 5 Calibration items and calibration methods (4)
- 5.1 Calibration Project (4)
- 5.2 Appearance and Functional Inspection (4)
- 5.3 Source output frequency (5)
- 5.4 Source output sine wave amplitude (5)
- 5.5 Source output sine wave distortion (total harmonic distortion) (6)
- 5.6 Source Output DC Bias (7)
- 5.7 Input resistance (7)
- 5.8 Single channel amplitude (7)
- 5.9 Single Channel Phase (9)
- 5.10 Channel Consistency (10)
- 5.11 Amplitude ratio between channels (11)
- 5.12 Phase difference between channels (12)
- 5.13 Common mode rejection ratio (12)
- 5.14 Inter-channel isolation (13)
- 6 Calibration result expression (13)
- 7 Re-study interval (14)
- Appendix A Original Record Format (15)
- Appendix B Calibration Certificate Page Format (19)
- Appendix C Example of Calibration Uncertainty Evaluation (23)
1 Scope (1)
2 Overview (1)
3 Measurement characteristics (1)
3.1 Source output frequency (1)
3.2 Source output sine wave amplitude (1)
3.3 Source output sine wave distortion (total harmonic distortion) (1)
3.4 Source Output DC Offset (1)
3.5 Input resistance (1)
3.6 Single channel amplitude (1)
3.7 Single Channel Phase (2)
3.8 Channel Consistency (2)
3.9 Amplitude ratio between channels (2)
3.10 Phase difference between channels (2)
3.11 Common mode rejection ratio (2)
3.12 Channel isolation (2)
4 Calibration conditions (2)
4.1 Environmental conditions (2)
4.2 Measurement standards and other equipment (2)
5 Calibration items and calibration methods (4)
5.1 Calibration Project (4)
5.2 Appearance and Functional Inspection (4)
5.3 Source output frequency (5)
5.4 Source output sine wave amplitude (5)
5.5 Source output sine wave distortion (total harmonic distortion) (6)
5.6 Source Output DC Bias (7)
5.7 Input resistance (7)
5.8 Single channel amplitude (7)
5.9 Single Channel Phase (9)
5.10 Channel Consistency (10)
5.11 Amplitude ratio between channels (11)
5.12 Phase difference between channels (12)
5.13 Common mode rejection ratio (12)
5.14 Inter-channel isolation (13)
6 Calibration result expression (13)
7 Re-study interval (14)
Appendix A Original Record Format (15)
Appendix B Calibration Certificate Page Format (19)
Appendix C Example of Calibration Uncertainty Evaluation (23)
Introduction
This specification is based on JJF 1071-2010 "Rules for the Preparation of National Metrology Calibration Specifications", related terms and uncertainties.
The qualitative assessment follows JJF 1001-2011 "General Measurement Terms and Definitions" and JJF 1059.1-2012 "Measurement is not accurate Qualitative assessment and representation.
This specification is the first release.
Frequency Response Analyzer Calibration Specifications
1 Scope
This specification applies to the calibration of frequency response analyzers with a frequency range below 50 MHz. Other instruments of the same type the calibration can be performed by reference.
2 Overview
Frequency response analyzers are widely used in aerospace,, marine, electrochemical, materials research, mechanical manufacturing, and rotary Turn to mechanical fault monitoring, fault diagnosis, modal parameter identification and other fields. Frequency response analyzer can directly analyze the system the frequency characteristics include amplitude frequency characteristics and phase frequency characteristics. The system is driven by the excitation of the built-in signal source of the frequency response analyzer.
The response signal is input to the frequency response analyzer for arithmetic processing, and finally according to polar coordinates (r, theta) or logarithmic pole the coordinate (logr, theta) form shows the frequency response result.
3 Measurement characteristics
3.1 Source output frequency Frequency range. 1mHz~50MHz;
Maximum allowable error. ±1×10-5.
3.2 Source output sine wave amplitude Range of amplitude. 10mV~10V (10Hz~65kHz);
10mV~5V (65kHz~1MHz);
10mV~2V (1MHz~10MHz);
10mV~1V (10MHz~20MHz);
10mV~0.5V (20MHz~35MHz);
10mV~0.25V (20MHz~50MHz).
Maximum allowable error. ± (1% ~ 5%) (10Hz ~ 35MHz);
± (5%~10%) (35MHz~50MHz).
3.3 Source output sine wave distortion (total harmonic distortion) < 2% (<=100kHz).
3.4 Source Output DC Bias Bias voltage range. -10V~ 10V;
Maximum allowable error. ± (1% × reading 10mV).
3.5 input resistance Input resistance. 1Mohm;
Maximum allowable error. ± 2%.
3.6 single channel amplitude Frequency range. 10Hz~50MHz;
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 25 pages — is available in the English PDF.
How to Download JJF 1710-2018
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
JJF 2425-2026 — Calibration specification for carbon dioxide incubators
JJF 1183-2025 — Calibration Specification for Temperature Transmitters
JJF 1282-2025 — Calibration Specification for Time Delay Relays
Secure payment via Stripe
Payments accepted
JJF 1710-2018
$535.00