JJF 1705-2018Calibration Specification for Artificial Mains Networks (English PDF)
This is a limited preview
Buy now to download the full PDF (15 pages)
Need quotation for your management?
Get a formal quotation for JJF 1705-2018 in 30 minutes.
Issued by
State Administration for Market Regulation
Level / Type
National · Mandatory
Issue date
June 25, 2018
Implementation date
September 25, 2018
Scope
JJF 1705-2018 (Calibration Specification for Artificial Mains Networks) is available as an English-translated PDF.
JJF 1705-2018 — This standard is applicable to V-type artificial power supply in accordance with GB/T 6113.102-2008 "Radio disturbance and immunity measurement equipment and measurement method specification Part 1-2: Radio disturbance and immunity measurement equipment auxiliary equipment conducted disturbance" Calibration of the network (hereafter referred to as "artificial power network").
Found what you need?
Document preview — JJF 1705-2018
National Standard of the People's Republic of China
- ICS
- 17.220
- Classification
- A 56
Issued by: State Administration for Market Regulation
Contents
- Introduction (II)
- 1 Scope (1)
- 2 References (1)
- 3 Terms (1)
- 3.1 Asymmetric voltage (1)
- 3.2 Test end impedance (1)
- 3.3 Partial pressure coefficient (1)
- 4 Overview (1)
- 5 Measurement characteristics (2)
- 5.1 Test end impedance (2)
- 5.2 Partial pressure coefficient (4)
- 6 Calibration conditions (4)
- 6.1 Environmental conditions (4)
- 6.2 Measurement standards and other equipment (5)
- 7 Calibration items and calibration methods (5)
- 7.1 Appearance and normality check (5)
- 7.2 Calibration of the test end impedance (5)
- 7.3 Calibration of partial pressure coefficient (6)
- 8 Calibration result expression (7)
- 9 Re-study interval (8)
- Appendix A Original Record Format (9)
- Appendix B Calibration Certificate Page Format (10)
- Appendix C Example of Calibration Uncertainty Evaluation (11)
- Appendix D Reference Mechanical Structure for Calibration Adapter (17)
1 Scope (1)
2 References (1)
3 Terms (1)
3.1 Asymmetric voltage (1)
3.2 Test end impedance (1)
3.3 Partial pressure coefficient (1)
4 Overview (1)
5 Measurement characteristics (2)
5.1 Test end impedance (2)
5.2 Partial pressure coefficient (4)
6 Calibration conditions (4)
6.1 Environmental conditions (4)
6.2 Measurement standards and other equipment (5)
7 Calibration items and calibration methods (5)
7.1 Appearance and normality check (5)
7.2 Calibration of the test end impedance (5)
7.3 Calibration of partial pressure coefficient (6)
8 Calibration result expression (7)
9 Re-study interval (8)
Appendix A Original Record Format (9)
Appendix B Calibration Certificate Page Format (10)
Appendix C Example of Calibration Uncertainty Evaluation (11)
Appendix D Reference Mechanical Structure for Calibration Adapter (17)
Introduction
This specification is prepared in accordance with JJF 1071-2010 "Rules for the Preparation of National Metrology Calibration Specifications", JJF 1001 Measurement Terms and Definitions, JJF 1059.1-2012 "Measurement Uncertainty Evaluation and Representation" together constitute the support of this regulation the basic series of specifications for the development of the work.
This specification refers to GB/T 6113.102-2008 "Radio disturbance and immunity measurement equipment and measurement methods Part 1-2. Radio disturbance and immunity measurement equipment, auxiliary equipment conducted disturbances, GB/T 6113.201-2017 "Specifications for radio disturbance and immunity measuring equipment and methods of measurement - Part 2-1.
Radio disturbance and immunity measurement method for conducted disturbance measurement, GB 1002-2008 "Household and similar use list Compilation of relevant provisions for phase plug and socket type, basic parameters and dimensions.
This specification is the first release.
Artificial power network calibration specification
1 Scope
This specification applies to GB/T 6113.102-2008 "Radio disturbance and immunity measurement equipment and measurement".
Method Specification Part 1-2. Requirements for Conducted Harassment in Auxiliary Equipment for Radio Disturbance and Immunity Measurement Equipment Calibration of a V-type artificial power network (hereinafter referred to as "artificial power network"). Includes three types.
1) 50ohm/50µH 5ohm type, the operating frequency range is 9kHz~150kHz;
2) 50ohm/50µH type, the operating frequency range is 0.15MHz~30MHz;
3) 50ohm/5µH 1ohm type, the operating frequency range is 0.15MHz~108MHz.
2 reference files
This specification refers to the following documents.
GB/T 6113.102-2008 Specification for radio disturbance and immunity measuring equipment and measuring methods - Part 1-2 Points. Radio disturbance and immunity measurement equipment auxiliary equipment conducted disturbance GB/T 6113.201 Radio disturbance and immunity measurement equipment and methods of measurement - Part 2-1.
Line electrical disturbance and immunity measurement method conducted disturbance measurement GB 1002 Single-phase plug and socket type and basic parameters and dimensions for household and similar purposes for dated references, only dated versions apply to this specification; undated quotations the latest version (including all amendments) applies to this specification.
3 terms
3.1 asymmetric voltage unsymmetricvoltage the vector magnitude of the RF disturbance voltage that appears between a single power terminal and ground.
3.2 Test end impedance EUTportimpedance Refers to the line terminal and reference of the device under test when the disturbance output of the artificial power network is terminated with a 50ohm load impedance.
High frequency impedance (modulus and phase angle) between the test sites.
3.3 partial pressure coefficient voltagedivisionfactor Refers to the high frequency signal fed from the device under test, transmitted to the disturbance output via the internal power supply network (built-in attenuation) the magnitude of the amplitude experienced by the device within the calculation range.
4 Overview
The artificial power network is an instrument used in electromagnetic compatibility radio disturbance measurement tests to measure power lines and parameters.
The disturbance voltage radiated externally between the test sites is usually an asymmetric voltage. Artificial power network in the harassment test the role of the quantity is.
1) providing a specified impedance to the terminals of the device under test in the RF frequency range;
2) coupling the disturbance voltage emitted by the device under test to the disturbance measuring device;
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.
How to Download JJF 1705-2018
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
JJF 2425-2026 — Calibration specification for carbon dioxide incubators
JJF 1183-2025 — Calibration Specification for Temperature Transmitters
JJF 1282-2025 — Calibration Specification for Time Delay Relays
Secure payment via Stripe
Payments accepted
JJF 1705-2018
$295.00