JJF 1701.6-2019Program of Pattern Evaluation of Instrument Transformers--Part 6: Three-phase Combined Instrument Transformers (English PDF)

测量用互感器型式评价大纲 第6部分:三相组合互感器

Preview PDF

This is a limited preview

Buy now to download the full PDF (39 pages)

Need quotation for your management?

Get a formal quotation for JJF 1701.6-2019 in 30 minutes.

Issued by

State Administration for Market Regulation

Level / Type

National · Mandatory

Issue date

January 1, 2019

Implementation date

March 31, 2020

Scope

JJF 1701.6-2019 is the English-translated version of 测量用互感器型式评价大纲 第6部分:三相组合互感器.

JJF 1701.6-2019 is the Chinese standard "Program of Pattern Evaluation of Instrument Transformers--Part 6: Three-phase Combined Instrument Transformers".

Found what you need?

Document preview — JJF 1701.6-2019

National Standard of the People's Republic of China

ICS
17.220

Contents

  • Introduction (III)
  • 1 Scope (1)
  • 2 References (1)
  • 3 Terms and definitions (1)
  • 3.1 Routine test (1)
  • 3.2 Three-phase combined transformer (2)
  • 3.3 Three-phase voltage transformer (2)
  • 3.4 Three-phase V-junction combined transformer (2)
  • 3.5 Three-phase Y-connection combined transformer (2)
  • 4 Overview (2)
  • 5 Legal management requirements (3)
  • 5.1 Unit of measurement (3)
  • 5.2 External structure (3)
  • 5.3 Logo (3)
  • 5.4 Submitted technical materials (4)
  • 6 Measurement requirements (4)
  • 6.1 Accuracy level (4)
  • 6.2 Measurement interval (4)
  • 6.3 Winding polarity (5)
  • 6.4 Basic error (5)
  • 6.5 Running deterioration (6)
  • 6.6 Magnetic saturation margin (6)
  • 7 General technical requirements (6)
  • 7.1 Working conditions (6)
  • 7.2 Appearance and structure (7)
  • 7.3 Electrical performance (8)
  • 7.4 Mechanical properties (12)
  • 8 List of Type Evaluation Items (12)
  • 9 Provide the number of prototypes and how to use them (14)
  • 9.1 General requirements (14)
  • 9.2 Number of prototypes provided (14)
  • 9.3 How to use the prototype (14)
  • 10 Test conditions and methods of test items, data processing and qualification criteria (14)
  • 10.1 Test conditions of the project (14)
  • 10.2 Inspection of signs (16)
  • 10.3 Winding polarity (16)
  • 10.4 Basic error (16)
  • 10.5 Operational deterioration (21)
  • 10.6 Magnetic saturation margin test (21)
  • 10.7 Primary power frequency withstand voltage test (22)
  • 10.8 Partial discharge test (23)
  • 10.9 Secondary-end power frequency withstand voltage test (26)
  • 10.10 Excitation characteristic test (27)
  • 10.11 Turn-to-turn overvoltage test (28)
  • 10.12 Capacitance and dielectric loss factor measurement (30)
  • 10.13 Insulation oil performance test (30)
  • 10.14 Temperature rise test (32)
  • 10.15 Primary end impact pressure test (33)
  • 10.16 Primary end cut-off lightning impulse withstand voltage test (33)
  • 10.17 Wet test of outdoor three-phase combined transformer (34)
  • 10.18 Short-term current test (35)
  • 10.19 Short circuit withstand capability test (36)
  • 10.20 Shell protection level test (38)
  • 10.21 Sealing performance at ambient temperature (38)
  • 11 Table of measuring instruments and equipment used in test items (39)
  • Appendix A Type Evaluation Record Format (41)
  • Appendix B Type Evaluation Report Format (43)
  • Appendix C Format of "Description" for Type Evaluation Preservation Prototype (49)
  • Appendix D Direct Measurement Method of Magnetic Saturation Margin (50)

1 Scope (1)

2 References (1)

3 Terms and definitions (1)

3.1 Routine test (1)

3.2 Three-phase combined transformer (2)

3.3 Three-phase voltage transformer (2)

3.4 Three-phase V-junction combined transformer (2)

3.5 Three-phase Y-connection combined transformer (2)

4 Overview (2)

5 Legal management requirements (3)

5.1 Unit of measurement (3)

5.2 External structure (3)

5.3 Logo (3)

5.4 Submitted technical materials (4)

6 Measurement requirements (4)

6.1 Accuracy level (4)

6.2 Measurement interval (4)

6.3 Winding polarity (5)

6.4 Basic error (5)

6.5 Running deterioration (6)

6.6 Magnetic saturation margin (6)

7 General technical requirements (6)

7.1 Working conditions (6)

7.2 Appearance and structure (7)

7.3 Electrical performance (8)

7.4 Mechanical properties (12)

8 List of Type Evaluation Items (12)

9 Provide the number of prototypes and how to use them (14)

9.1 General requirements (14)

9.2 Number of prototypes provided (14)

9.3 How to use the prototype (14)

10 Test conditions and methods of test items, data processing and qualification criteria (14)

10.1 Test conditions of the project (14)

10.2 Inspection of signs (16)

10.3 Winding polarity (16)

10.4 Basic error (16)

10.5 Operational deterioration (21)

10.6 Magnetic saturation margin test (21)

10.7 Primary power frequency withstand voltage test (22)

10.8 Partial discharge test (23)

10.9 Secondary-end power frequency withstand voltage test (26)

10.10 Excitation characteristic test (27)

10.11 Turn-to-turn overvoltage test (28)

10.12 Capacitance and dielectric loss factor measurement (30)

10.13 Insulation oil performance test (30)

10.14 Temperature rise test (32)

10.15 Primary end impact pressure test (33)

10.16 Primary end cut-off lightning impulse withstand voltage test (33)

10.17 Wet test of outdoor three-phase combined transformer (34)

10.18 Short-term current test (35)

10.19 Short circuit withstand capability test (36)

10.20 Shell protection level test (38)

10.21 Sealing performance at ambient temperature (38)

11 Table of measuring instruments and equipment used in test items (39)

Appendix A Type Evaluation Record Format (41)

Appendix B Type Evaluation Report Format (43)

Appendix C Format of "Description" for Type Evaluation Preservation Prototype (49)

Appendix D Direct Measurement Method of Magnetic Saturation Margin (50)

Introduction

This outline is based on JJF 1016-2014 "Guidelines for the Compilation of Outlines for Measuring Apparatus Type Evaluation", JJF 1015-2014 Compiled with "General Specification for Type Evaluation of Measuring Instruments".

This outline is published for the first time.

Outline of type evaluation for measuring transformer Part 6: Three-phase combined transformer

1 Scope

This outline is applicable to the type evaluation of three-phase combined transformers with a classification code of 15280000.

This outline is applicable to the measurement of power supply gas, the rated frequency is 50Hz, and the maximum voltage of the equipment is Um Electromagnetic three-phase combined transformer.

2 Reference documents the outline cited the following documents.

JJG313 measuring current transformer JJG314 measuring voltage transformer GB/T 4208-2017 enclosure protection level (IP code) GB/T 4756 Manual sampling method of petroleum liquid GB/T 5465.2 Graphical symbols for electrical equipment Part 2: Graphical symbols GB/T 5585.1 Copper, aluminum and its alloy busbars for electrical purposes Part 1: Copper and copper alloy busbars GB/T 7354 Partial discharge measurement of high voltage test technology GB/T 16927.1 High voltage test technology Part 1: General definition and test requirements GB/T 16927.2 High voltage test technology Part 2: Measurement system GB/T.20138 Protection level of electrical equipment shell against external mechanical collision (IK code) GB/T 20840.1-2010 Transformers Part 1: General technical requirements GB/T 20840.2 Transformers Part 2: Supplementary technical requirements for current transformers GB/T 20840.3-2013 Transformers Part 3: Supplementary technical requirements for electromagnetic voltage transformers GB/T 20840.4-2015 Transformers Part 4: Supplementary technical requirements for combined transformers GB/T 22071.1-2018 Test Guide for Transformer Part 1: Current Transformer GB/T 22071.2-2017 Test Guide for Transformer Part 2: Electromagnetic Voltage Transformer JB/T 5895-1991 Guidelines for the use of insulators in polluted areas JB/T 10432 three-phase combined transformer JB/T 10433 three-phase voltage transformer for dated reference documents, only the dated version applies to this specification; for those without date references the latest version (including all amendments) is applicable to this specification.

3 Terms and definitions GB/T 20840.1, GB/T 20840.2, GB/T 20840.3, GB/T 20840.4 and JB/T 10432 the terms and definitions defined in and below apply to this outline.

3.1 routine test in order to reflect the manufacturing defects, each equipment withstands the test. These tests do not damage the characteristics and reliability of the product.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 39 pages — is available in the English PDF.

How to Download JJF 1701.6-2019

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Fast delivery

    After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
39 pages
Fast delivery
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

JJF 1701.6-2019

$900.00