Document preview — JJF 1679-2017
National Standard of the People's Republic of China
- ICS
- 17.220
- Classification
- A 56
Issued by: General Administration of Quality Supervision, Inspection and Quarantine
Contents
- Introduction (II)
- 1 Scope (1)
- 2 References (1)
- 3 Terms (1)
- 4 Overview (1)
- 5 Metrological characteristics (1)
- 5.1 Reference Crystal Oscillator (1)
- 5.2 RF Output Signal (1)
- 5.3 Output Digital Modulation Signal (1)
- 5.4 Power Measurement (2)
- 5.5 Digital Demodulation Analysis (2)
- 6 Calibration Conditions (2)
- 6.1 Environmental Conditions (2)
- 6.2 Measurement Standards and Other Equipment (2)
- 7 Calibration Items and Calibration Methods (3)
- 7.1 Calibration Items (3)
- 7.2 Inspection of appearance and work (3)
- 7.3 Reference Crystal Oscillator Frequency (4)
- 7.4 RF Output Signal Frequency (4)
- 7.5 RF Output Signal Power (4)
- 7.6 Output Digital Modulation Signal Digital Modulation Quality Parameters (4)
- 7.7 Output Digital Modulation Signal Adjacent Channel Power (5)
- 7.8 Power Measurement (5)
- 7.9 Digital Demodulation Analysis (6)
- 8 Calibration Results (6)
- 9 Re-school interval (7)
- Appendix A Original Recording Format (8)
- Appendix B Internal Format of Calibration Certificate (12)
- Appendix C Evaluation Examples of Measurement Uncertainty for Main Project Calibration Results (16)
1 Scope (1)
2 References (1)
3 Terms (1)
4 Overview (1)
5 Metrological characteristics (1)
5.1 Reference Crystal Oscillator (1)
5.2 RF Output Signal (1)
5.3 Output Digital Modulation Signal (1)
5.4 Power Measurement (2)
5.5 Digital Demodulation Analysis (2)
6 Calibration Conditions (2)
6.1 Environmental Conditions (2)
6.2 Measurement Standards and Other Equipment (2)
7 Calibration Items and Calibration Methods (3)
7.1 Calibration Items (3)
7.2 Inspection of appearance and work (3)
7.3 Reference Crystal Oscillator Frequency (4)
7.4 RF Output Signal Frequency (4)
7.5 RF Output Signal Power (4)
7.6 Output Digital Modulation Signal Digital Modulation Quality Parameters (4)
7.7 Output Digital Modulation Signal Adjacent Channel Power (5)
7.8 Power Measurement (5)
7.9 Digital Demodulation Analysis (6)
8 Calibration Results (6)
9 Re-school interval (7)
Appendix A Original Recording Format (8)
Appendix B Internal Format of Calibration Certificate (12)
Appendix C Evaluation Examples of Measurement Uncertainty for Main Project Calibration Results (16)
Introduction
This calibration specification is based on JJF 1071-2010 "Rules for the preparation of national metrological calibration specifications", JJF 1059.1-2012 "Measurement and Expression of Measurement Uncertainty".
This calibration specification refers to the IEEE standard 802.15.4-2011 LAN and MAN. Low-rate wireless personal Regional networks (LR-WPANs).
This specification is the first release.
ZigBee comprehensive tester calibration specification
1 Scope
This specification applies to the ZigBee integrated tester in the 2.4 GHz band (2.402 GHz to 2.484 GHz) for calibration, of other ZigBee combo testers can refer to this specification.
2 references
IEEE Standard 802.15.4-2011 LAN and MAN. Low Rate Wireless Personal Area Network (LR-WPANs). [IEEE Std 802.15.4TM-2011, IEEEStandardforLocalandmetropolitanarea networks-Part 15.4. Low-RateWirelessPersonalAreaNetworks(LR-WPANs)].
For dated references, only dated editions apply to this specification; all undated references the latest version (including all amendments) applies to this specification.
3 Terms
3.1 ZigBee
Economical, High-Efficiency, Low Data Rate (less than 250 kbit/s) Wireless Defined by IEEE Std 802.15.4 Domain-based network technology, operating in the 2.4GHz open band, supporting asynchronous data services, and supporting synchronous data industry Service, star or mesh networking communication.
4 Overview
ZigBee comprehensive tester is composed of reference crystal oscillator, digital modulation signal generator, power analyzer and number A comprehensive test instrument consisting of functional modules such as a word modulation analyzer was produced, developed and tested at the ZigBee terminal.
Chengzhong used for power, frequency, modulation and other parameters of the test.
5 Metrological characteristics
5.1 Reference Crystal Oscillator Frequency range and frequency deviation. 10 MHz; ±1×10-6.
5.2 RF output signal
5.2.1 Output frequency range and frequency deviation. 2.402 GHz to 2.484 GHz; ±1×10-6.
5.2.2 Output Power Range and Maximum Allowable Error. -90dBm~0dBm; ±1.0dB.
5.3 Output Digital Modulation Signal
5.3.1 Digital Modulation Quality Parameters Root mean square error vector magnitude (EVM). <= 2%.
5.3.2 Adjacent channel power the spectrum emission template is shown in Table 1 and Figure 1.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 20 pages — is available in the English PDF.
How to Download JJF 1679-2017
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
JJF 2425-2026 — Calibration specification for carbon dioxide incubators
JJF 1183-2025 — Calibration Specification for Temperature Transmitters
JJF 1282-2025 — Calibration Specification for Time Delay Relays
Secure payment via Stripe
Payments accepted
JJF 1679-2017
$420.00