JJF 1676-2017Calibration Specification for Temperature Parameter of Passive Medical Cold Boxes (English PDF)
This is a limited preview
Buy now to download the full PDF (13 pages)
Need quotation for your management?
Get a formal quotation for JJF 1676-2017 in 30 minutes.
Issued by
General Administration of Quality Supervision, Inspection and Quarantine
Level / Type
National · Mandatory
Issue date
November 20, 2017
Implementation date
February 20, 2018
Scope
JJF 1676-2017 (Calibration Specification for Temperature Parameter of Passive Medical Cold Boxes) is available as an English-translated PDF.
JJF 1676-2017 — This standard is applicable to the calibration of temperature parameters of passive medical refrigerators that have a temperature range of (-20 to 20)��C, temperature display and temperature sensor probe exposed, and the temperature parameters of passive medical refrigerators in other insulation temperature zones.
Found what you need?
Document preview — JJF 1676-2017
National Standard of the People's Republic of China
- ICS
- 17.200
- Classification
- A 54
Issued by: General Administration of Quality Supervision, Inspection and Quarantine
Contents
- Introduction (II)
- 1 Scope (1)
- 2 Terms (1)
- 2.1 Passive Medical Refrigerator (1)
- 2.2 Coolant (1)
- 3 Overview (1)
- 4 Metrological characteristics and other requirements (1)
- 4.1 Metrological characteristics (1)
- 4.2 Other Technical Requirements (1)
- 5 Calibration Conditions (2)
- 5.1 Environmental Conditions (2)
- 5.2 Measurement Standards and Other Equipment (2)
- 6 Calibration Items and Calibration Methods (2)
- 6.1 Calibration Items (2)
- 6.2 Calibration Methods (2)
- 6.3 Data Processing (3)
- 7 Expression of Calibration Results (3)
- 7.1 Calibration Record (3)
- 7.2 Processing of Calibration Results (3)
- 8 Re-school interval (4)
- Appendix A Tests for Holding Time of Vaccine Refrigerated Containers and Vaccine Carrying Cases (5)
- Appendix B Test for Holding Time of Refrigerator (without Refrigerant Load) (8)
- Appendix C Calibration Record Format (9)
- Appendix D Example of Evaluation of Uncertainty in Measurement of Temperature Indicator Errors in Refrigerators (11)
- Appendix E Internal Format of Calibration Certificate (14)
1 Scope (1)
2 Terms (1)
2.1 Passive Medical Refrigerator (1)
2.2 Coolant (1)
3 Overview (1)
4 Metrological characteristics and other requirements (1)
4.1 Metrological characteristics (1)
4.2 Other Technical Requirements (1)
5 Calibration Conditions (2)
5.1 Environmental Conditions (2)
5.2 Measurement Standards and Other Equipment (2)
6 Calibration Items and Calibration Methods (2)
6.1 Calibration Items (2)
6.2 Calibration Methods (2)
6.3 Data Processing (3)
7 Expression of Calibration Results (3)
7.1 Calibration Record (3)
7.2 Processing of Calibration Results (3)
8 Re-school interval (4)
Appendix A Tests for Holding Time of Vaccine Refrigerated Containers and Vaccine Carrying Cases (5)
Appendix B Test for Holding Time of Refrigerator (without Refrigerant Load) (8)
Appendix C Calibration Record Format (9)
Appendix D Example of Evaluation of Uncertainty in Measurement of Temperature Indicator Errors in Refrigerators (11)
Appendix E Internal Format of Calibration Certificate (14)
Introduction
This specification was drafted in accordance with JJF 1071-2010 "Rules for the preparation of national metrological calibration specifications", in which measurement uncertainty the degree of assessment was conducted in accordance with JJF 1059.1-2012 Evaluation and Expression of Measurement Uncertainty.
This specification is the first release.
Passive medical refrigerator temperature parameter calibration specification
1 Scope
This specification applies to the temperature range of the insulation in the (-20~20) °C range, there is a temperature display and thermometer outside the temperature probe the calibration of the temperature parameters of the passive medical refrigerator and the calibration of the temperature parameters of the passive medical refrigerator in other temperature zones Also refer to this specification.
2 Terms
2.1 passive medical refrigerator box passivemedicalcoldbox Applied to the medical industry, relying solely on cold storage and insulation structure refrigerated insulation device.
2.2 Coolant Coolant
It can absorb and store a large amount of cold at low temperatures, and at the higher temperatures it can release a large amount of cold, which can be longer the substance that maintains a low temperature environment in and around itself.
3 Overview
Passive medical refrigerators are heat-insulating boxes made of highly efficient heat-insulating materials, and a certain amount of cold storage agent is placed inside.
In a closed state, it is possible to effectively maintain the device at a relatively low temperature in the case for a long time. Refrigerated boxes are usually used to save Items such as medicines, reagents, samples, blood and biological products stored and transported under low temperature conditions have different uses.
Also known as vaccine refrigerated containers, vaccine carrying cases, blood transport containers, drug refrigerated containers, specimen receiving containers, biosafety all transport freezer and so on.
The passive medical refrigerated box with its own temperature display consists of an incubator, a cooling agent and a digital thermometer.
The internal volume is usually not more than 60L and the ambient temperature is not higher than 55°C. The insulation temperature zone of the refrigerator is due to its expectation Different from the requirements and the type of coolant, the temperature range of the passive medical refrigerator is usually no more than (-20~
20) °C, wherein the most commonly used temperature range is (2 ~ 8) °C.
The domestic refrigerator manufacturers claim that the temperature of the cold storage box is usually a multiple of 12h, such as 12h, 24h, 48h, 72h or 96h, etc., the test is usually carried out with reference to the vaccine refrigerated box or vaccine provided by the World Health Organization (WHO).
The test method for the box holding time (see Appendix A). Some refrigerator manufacturers provide free storage of cooling agent with the tank for the preservation time of the refrigerator, see Appendix B for the test method. The manufacturer's stated holding time is usually not when the coolant is not loaded.
6h or more.
4 Metrological characteristics and other requirements
4.1 Measurement Characteristics Temperature indication error. no more than ±1°C (or meet product specification requirements).
4.2 Other technical requirements
4.2.1 Passive medical refrigerator (hereinafter referred to as refrigerator) logo should be complete, clear, and has the following information.
Manufacturer name or trademark, model/specification, serial number, etc.; vaccine refrigerated containers and vaccine carrying containers should be in obvious positions (Box Cover or Box Front) Give an open box warning sign.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 13 pages — is available in the English PDF.
How to Download JJF 1676-2017
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
JJF 2425-2026 — Calibration specification for carbon dioxide incubators
JJF 1183-2025 — Calibration Specification for Temperature Transmitters
JJF 1282-2025 — Calibration Specification for Time Delay Relays
Secure payment via Stripe
Payments accepted
JJF 1676-2017
$235.00