Valid

JJF 1667-2017Calibration Specification for Harmonics Analyzing Instruments at Power Frequency (English PDF)

Preview PDF

This is a limited preview

Buy now to download the full PDF (22 pages)

Need quotation for your management?

Get a formal quotation for JJF 1667-2017 in 30 minutes.

Issued by

General Administration of Quality Supervision, Inspection and Quarantine

Level / Type

National · Mandatory

Issue date

November 20, 2017

Implementation date

February 20, 2018

Scope

JJF 1667-2017 (Calibration Specification for Harmonics Analyzing Instruments at Power Frequency) is available as an English-translated PDF.

JJF 1667-2017 — This standard applies to the calibration of industrial frequency harmonic measuring instruments (including harmonic analyzers and standard harmonic power sources).

This type of instrument operates under laboratory conditions with fundamental frequencies in the 45 Hz to 65 Hz range, with harmonic voltage, harmonic current, and harmonic power measurements, or some of their functions.

For the calibration of the harmonic measurement function of the standard power meter and the standard power meter, refer to this standard.

Found what you need?

Document preview — JJF 1667-2017

National Standard of the People's Republic of China

ICS
17.220
Classification
A 55

Issued by: General Administration of Quality Supervision, Inspection and Quarantine

Contents

  • Introduction (II)
  • 1 Scope (1)
  • 2 References (1)
  • 3 Terms and units of measure (1)
  • 3.1 Harmonics [Components] (1)
  • 3.2 Harmonic Absolute Error (1)
  • 3.3 Harmonic Relative Error (1)
  • 3.4 Harmonic Reference Error (1)
  • 3.5 Harmonic content rate error (2)
  • 4 Overview (2)
  • 5 Metrological characteristics (2)
  • 5.1 Fundamental Frequency, Voltage, Current, and Power (2)
  • 5.2 Fundamental and Individual Harmonics Combined Voltage and Current (2)
  • 5.3 Power of Combination of Fundamental and Individual Harmonics (2)
  • 5.4 Voltage, Current, and Power of Integrated Waveforms (2)
  • 5.5 Vacant Harmonic Voltage and Current (2)
  • 6 Calibration Conditions (3)
  • 6.1 Environmental Conditions (3)
  • 6.2 Measurement Standards and Other Equipment (3)
  • 7 Calibration Items and Calibration Methods (4)
  • 7.1 Calibration Items (4)
  • 7.2 Calibration Methods (4)
  • 8 Expression of Calibration Results (7)
  • 9 Re-school interval (8)
  • Appendix A Formulation of Harmonic Voltage and Harmonic Current (9)
  • Appendix B Measurement Standards and Wiring with School Instruments (11)
  • Appendix C Calibration Original Recording Format (12)
  • Appendix D Calibration Certificate Inner Page Format (18)
  • Appendix E Examples of Evaluation of Measurement Uncertainty for Power Frequency Harmonic Measurement Instruments (25)

1 Scope (1)

2 References (1)

3 Terms and units of measure (1)

3.1 Harmonics [Components] (1)

3.2 Harmonic Absolute Error (1)

3.3 Harmonic Relative Error (1)

3.4 Harmonic Reference Error (1)

3.5 Harmonic content rate error (2)

4 Overview (2)

5 Metrological characteristics (2)

5.1 Fundamental Frequency, Voltage, Current, and Power (2)

5.2 Fundamental and Individual Harmonics Combined Voltage and Current (2)

5.3 Power of Combination of Fundamental and Individual Harmonics (2)

5.4 Voltage, Current, and Power of Integrated Waveforms (2)

5.5 Vacant Harmonic Voltage and Current (2)

6 Calibration Conditions (3)

6.1 Environmental Conditions (3)

6.2 Measurement Standards and Other Equipment (3)

7 Calibration Items and Calibration Methods (4)

7.1 Calibration Items (4)

7.2 Calibration Methods (4)

8 Expression of Calibration Results (7)

9 Re-school interval (8)

Appendix A Formulation of Harmonic Voltage and Harmonic Current (9)

Appendix B Measurement Standards and Wiring with School Instruments (11)

Appendix C Calibration Original Recording Format (12)

Appendix D Calibration Certificate Inner Page Format (18)

Appendix E Examples of Evaluation of Measurement Uncertainty for Power Frequency Harmonic Measurement Instruments (25)

Introduction

This specification is based on JJF 1071-2010 "Rules for the preparation of national metrological calibration specifications", JJF 1059.1-2012 "Evaluation and Expression of Measurement Uncertainty" was compiled.

This specification refers to the following documents.

JJG1106-2015 Verification Standard for Static Harmonic Active Energy Meters for Work Use;

GB/T 17626.7-2008 "Electromagnetic compatibility test and measurement technology power supply system and connected equipment harmonics, Harmonic wave measurement and measurement instrument guidelines";

IEC 61000-4-30:2008 "Electromagnetic Compatibility Part 4-30 Test and Measurement Technology Power Quality Measurement Method (Electromagneticcompatibility (EMC)-Part 4-30. Testingandmeasurement techniques-Powerqualitymeasurementmethods).

This specification is the first release.

Frequency harmonic measuring instrument calibration specification

1 Scope

This specification applies to the calibration of power frequency harmonic measuring instruments (including harmonic analyzers and standard harmonic power sources). This the instrument works under laboratory conditions, with a fundamental frequency in the range of 45Hz to 65Hz, with harmonic voltage, harmonics Wave current and harmonic power measurements, or some of them.

For the calibration of the harmonic measurement function of the standard power meter and the standard power meter, refer to this specification.

This specification does not apply to the calibration of interharmonic waves.

2 references

This specification refers to the following documents.

JJF 1245.3-2010 Installed energy meter type evaluation outline special requirements static active energy meter (0.2S, 0.5S, 1 and 2) GB/T 17215.302-2013 Particular requirements for alternating current measuring equipment Part 2. Static harmonics Energy meter GB/T 17215.321-2008 Particular requirements for alternating current measuring equipment Part 21. Static active power Energy Meter (Level 1 and Level 2) OIMLR46Edition2012(E). Active Electrical Energy Meters for dated references, only dated editions apply to this specification; all undated references the latest version (including all amendments) applies to this specification.

3 Terms and units of measure

3.1 Harmonics [component] harmonic (component) the number of periods in the Fourier series is a component of an integer greater than one.

Note.

1 In this specification, DC [component] is considered as a harmonic of the order 0.

2 See Annex A for formulae for expressions related to harmonic voltages, harmonic currents, and harmonic powers formed by them.

3 Rewrite GB/T 17215.302-2013, definition 3.4.

3.2 Harmonic Absolute Error HARMONIC INDICATORS MEASUREMENT OF HARMONIC INDICATORS AND REFERENCE VALUES (THE SAME HARMONIC INDICATIONS PROVIDED BY MEASUREMENT STANDARD DEVICES) the difference between. V, mV, µV (harmonic voltage); A, mA, µA (harmonic current); or W, mW, µW (Harmonic power) is expressed.

3.3 Harmonic Relative Error the ratio of harmonic absolute error to the reference value. With mV/V, µV/V (harmonic voltage); mA/A, µA/A (harmonic) Wave current); or mW/W, µW/W (harmonic power), can also be expressed as a percentage.

3.4 Harmonic reference error harmonicfiducialerror

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 22 pages — is available in the English PDF.

How to Download JJF 1667-2017

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
22 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

JJF 1667-2017