Scope

JJF 1666-2017 (Calibration Specification for Automatic Quantitative Analyzers of Microorganism) is available as an English-translated PDF.

JJF 1666-2017 — This standard applies to the calibration of a microbiological quantitative analyzer using the principles of fluorescence detection and maximum possible number method.

Found what you need?

Document preview — JJF 1666-2017

National Standard of the People's Republic of China

ICS
17.020
Classification
A 50

Issued by: General Administration of Quality Supervision, Inspection and Quarantine

Contents

  • Introduction (II)
  • 1 Scope (1)
  • 2 References (1)
  • 3 Terms (1)
  • 3.1 Poisson distribution (1)
  • 3.2 The largest possible number method (1)
  • 4 Overview (1)
  • 5 Metrological characteristics (1)
  • 5.1 Injection Pressure Stability (1)
  • 5.2 Reproducibility of injection pressure (1)
  • 5.3 Excitation wavelength (1)
  • 5.4 Uniformity of excitation light intensity (1)
  • 5.5 Excitation light intensity stability (1)
  • 6 Calibration Conditions (2)
  • 6.1 Environmental Conditions (2)
  • 6.2 Equipment for calibration (2)
  • 7 Calibration Items and Calibration Methods (2)
  • 7.1 General Inspection (2)
  • 7.2 Injection Pressure Stability and Repeatability (2)
  • 7.3 Excitation wavelength and excitation light intensity (3)
  • 8 Expression of Calibration Results (3)
  • 9 Re-school interval (4)
  • Appendix A Calibration Certificate (inside page) Reference Format (5)
  • Appendix B Calibration Original Record Reference Format (6)
  • Appendix C Example of Wavelength Calibration Uncertainty (8)

1 Scope (1)

2 References (1)

3 Terms (1)

3.1 Poisson distribution (1)

3.2 The largest possible number method (1)

4 Overview (1)

5 Metrological characteristics (1)

5.1 Injection Pressure Stability (1)

5.2 Reproducibility of injection pressure (1)

5.3 Excitation wavelength (1)

5.4 Uniformity of excitation light intensity (1)

5.5 Excitation light intensity stability (1)

6 Calibration Conditions (2)

6.1 Environmental Conditions (2)

6.2 Equipment for calibration (2)

7 Calibration Items and Calibration Methods (2)

7.1 General Inspection (2)

7.2 Injection Pressure Stability and Repeatability (2)

7.3 Excitation wavelength and excitation light intensity (3)

8 Expression of Calibration Results (3)

9 Re-school interval (4)

Appendix A Calibration Certificate (inside page) Reference Format (5)

Appendix B Calibration Original Record Reference Format (6)

Appendix C Example of Wavelength Calibration Uncertainty (8)

Introduction

This specification mainly refers to GB 4789.3 National Food Safety Standard for Food Microbiology to Test Coliforms Counting, GB/T 5750.12 "Microbiological criteria for standard methods of drinking water for drinking" and based on JJF 1071 the formulation of the "Rules for the preparation of national measurement calibration specifications".

This specification is the first release.

Automatic Microbiological Analyzer Calibration Specification

1 Scope

This specification applies to the calibration of a microbiological quantitative analyzer using the principle of fluorescence detection and maximum possible number method. other the same principle of microbiological quantitative analyzer can refer to this specification.

2 references

This specification refers to the following documents.

JJF 1071-2010 Rules for the preparation of national metrological calibration specifications GB 4789.3 Food Safety National Standard for Food Microbiological Examination of Coliform Count GB/T 5750.12 Standard Test Method for Drinking Water Microbiological Index for dated references, only dated editions apply to this specification; all undated references the latest version (including all amendments) applies to this specification.

3 Terms

The definitions of GB 4789.3 and GB/T 5750.12 and the following terms and definitions apply to this specification.

3.1 Poisson distribution Poissondistribution the Poisson distribution is a discrete probability distribution that is common in statistics and probability (discreteprobabilitydistri-Bution), suitable for describing the number of random events occurring within a unit of time (or space).

3.2 The most probable number method, MPN an indirect counting method based on Poisson distribution, also known as diluted culture counting, is a variety of calculations in microbial detection the most common method for the number of sample microorganisms.

4 Overview

The automatic microbial quantitative analyzer (hereinafter referred to as the instrument) is based on the principle of fluorescence detection and maximum possible number method.

An instrument for quantitative analysis of microorganisms. The instrument consists of a sample preparation system and a reading system. Sample preparation system the sample and the specific medium are added to the card. Reading system is detected by fluorescence, based on the number of positive holes Calculate the result.

5 Metrological characteristics

5.1 Injection pressure stability

5.2 Reproducibility of injection pressure

5.3 Excitation wavelength

5.4 Uniformity of excitation light intensity

5.5 Excited light intensity stability

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 9 pages — is available in the English PDF.

How to Download JJF 1666-2017

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
9 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

JJF 1666-2017

$205.00