Valid

JJF 1664-2017Calibration Specification for Temperature Indicators (English PDF)

Preview PDF

This is a limited preview

Buy now to download the full PDF (17 pages)

Need quotation for your management?

Get a formal quotation for JJF 1664-2017 in 30 minutes.

Issued by

General Administration of Quality Supervision, Inspection and Quarantine

Level / Type

National · Mandatory

Issue date

November 20, 2017

Implementation date

February 20, 2018

Scope

JJF 1664-2017 (Calibration Specification for Temperature Indicators) is available as an English-translated PDF.

JJF 1664-2017 — This standard applies to temperature display instruments that accept temperature sensors such as thermocouples and thermal resistors or temperature transmitter output signals, including the calibration of the temperature display part of the process measurement control system.

Found what you need?

Document preview — JJF 1664-2017

National Standard of the People's Republic of China

ICS
17.200
Classification
A 54

Issued by: General Administration of Quality Supervision, Inspection and Quarantine

Contents

  • Introduction (II)
  • 1 Scope (1)
  • 2 References (1)
  • 3 Overview (1)
  • 4 Metrological characteristics (2)
  • 4.1 Error indication (2)
  • 4.2 Safety Performance (2)
  • 5 Calibration Conditions (2)
  • 5.1 Standard Equipment and Other Equipment (2)
  • 5.2 Environmental Conditions (3)
  • 6 Calibration Items and Calibration Methods (3)
  • 6.1 Calibration and Inspection Items (3)
  • 6.2 Calibration Methods (3)
  • 6.3 Data Processing Principles (7)
  • 7 Expression of Calibration Results (7)
  • 8 Re-school interval (8)
  • Annex A Digital Meter Representation Value Error Calibration Uncertainty Evaluation Example (9)
  • Appendix B Simulator Value Error Calibration Uncertainty Evaluation Example (12)
  • Appendix C Original Record Form (Reference) (15)
  • Appendix D Deviation Indicator Meter Measurement Record (Example) (18)
  • Appendix E The differential resistance of the thermal resistance and the Seebeck coefficient of the thermocouple (informative) (19)
  • Appendix F Internal Format of Calibration Certificate (21)

1 Scope (1)

2 References (1)

3 Overview (1)

4 Metrological characteristics (2)

4.1 Error indication (2)

4.2 Safety Performance (2)

5 Calibration Conditions (2)

5.1 Standard Equipment and Other Equipment (2)

5.2 Environmental Conditions (3)

6 Calibration Items and Calibration Methods (3)

6.1 Calibration and Inspection Items (3)

6.2 Calibration Methods (3)

6.3 Data Processing Principles (7)

7 Expression of Calibration Results (7)

8 Re-school interval (8)

Annex A Digital Meter Representation Value Error Calibration Uncertainty Evaluation Example (9)

Appendix B Simulator Value Error Calibration Uncertainty Evaluation Example (12)

Appendix C Original Record Form (Reference) (15)

Appendix D Deviation Indicator Meter Measurement Record (Example) (18)

Appendix E The differential resistance of the thermal resistance and the Seebeck coefficient of the thermocouple (informative) (19)

Appendix F Internal Format of Calibration Certificate (21)

Introduction

This specification was drafted in accordance with JJF 1071-2010 "Rules for the preparation of national metrological calibration specifications", in which measurement uncertainty the degree of assessment was conducted in accordance with JJF 1059.1-2012 Evaluation and Expression of Measurement Uncertainty. There is no temperature the publication of relevant international recommendations for display instruments, only the European Union's.2007 calibration guide EURAMET/cg-11/V.01 "Guideline calibration standards for temperatureindicators" Andsimulatorsbyelectricalsimulationandmeasurement) for reference, this specification is equivalent to the temperature display instrument part of the calibration principle, calibration requirements and uncertainty assessment.

This specification is the first release.

Temperature Indicator Calibration Specifications

1 Scope

This specification applies to the temperature of a temperature sensor signal such as a thermocouple, a thermal resistor, or a temperature transmitter output signal Display instrumentation, including calibration of the temperature display part of the process measurement control system. Accepts DC voltage or current process information the secondary instrument shown on the number can be calibrated with reference to this specification.

2 references

This specification refers to the following documents.

JJG617-1996 Digital Temperature Indicating Controller JJG951-2000 Analog Temperature Indicating Controller Thermocouples Part 1. Indexing Tables GB/T 16839.1-1997 JB/T 8622-1997 Technical conditions and indexing table for platinum resistance resistors JB/T 8623-1997 Technical conditions and index table for industrial copper thermal resistance for dated references, only the dated edition applies this specification; for undated references, the latest version (including all amendments) applies to this specification.

3 Overview

Temperature display instrument is an industrial process measurement instrument, also known as temperature secondary instrument. The meter itself cannot be alone to measure the temperature, it must match the temperature sensor and accept its signal to measure the temperature. Instrument input signal is a standard Qualified and normative signals usually include compliance with International Electrotechnical Commission (IEC ) standards, national standards, industry standards Qualified thermal resistance, thermocouple signals, and standardized (current, voltage) signals, and recognized standardization in specific fields signal. When the instrument is connected to the thermocouple to measure the temperature, it usually has the function of automatic compensation of the reference temperature.

The external cold junction compensator is directly connected to the thermocouple.

The types of thermal resistors commonly used today include Pt100, Pt500, Pt1000, Cu50, Cu100, etc.

The corresponding relationship of resistance (referred to as the index table, the same below) follows the JB/T 8622-1997 and JB/T 8623-1997 standards.

Quasi-required; common types of thermocouples are B, S, R, K, N, E, J, T, etc., and their temperature and potential values correspond to each other.

The relationship follows the requirements of the GB/T 16839.1-1997 standard; the instrument accepts a standardized DC signal as current 4mA~20mA, voltage 1V~5V and so on.

The characteristics of the instrument according to the temperature display can be divided into two major categories of digital instruments and analog instruments. Digital display meter press Classification of resolution, common resolution 0.1 °C and 1 °C. Analog display methods include pointer indications, ribbon indications, and There are three types of beam indicators, full scale indication and deviation indication combined with the set value.

The input signal of the instrument can be single, it can be compound, or it can be operated according to the specification.

Key settings.

Instrumentation block diagram shown in Figure 1.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 17 pages — is available in the English PDF.

How to Download JJF 1664-2017

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
17 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

JJF 1664-2017

$355.00