JJF 1658-2017Calibration Specification for Loss-of-voltage Timers (English PDF)

Preview PDF

This is a limited preview

Buy now to download the full PDF (12 pages)

Need quotation for your management?

Get a formal quotation for JJF 1658-2017 in 30 minutes.

Issued by

General Administration of Quality Supervision, Inspection and Quarantine

Level / Type

National · Mandatory

Issue date

November 20, 2017

Implementation date

February 20, 2018

Scope

JJF 1658-2017 (Calibration Specification for Loss-of-voltage Timers) is available as an English-translated PDF.

JJF 1658-2017 — This standard applies to the calibration of voltage-loss timers (pressure-loss timers, loss-of-voltage cut-off timers, loss-of-voltage cut-off short-circuit timers).

Found what you need?

Document preview — JJF 1658-2017

National Standard of the People's Republic of China

ICS
17.080
Classification
A 57

Issued by: General Administration of Quality Supervision, Inspection and Quarantine

Contents

  • Introduction (II)
  • 1 Scope (1)
  • 2 References (1)
  • 3 Terms and units of measure (1)
  • 3.1 Starting voltage (1)
  • 3.2 Return voltage (1)
  • 3.3 Starting current (1)
  • 3.4 Reference Voltage (1)
  • 4 Overview (1)
  • 5 Metrological characteristics (2)
  • 5.1 Clock Differencing (2)
  • 5.2 Starting voltage (2)
  • 5.3 Return voltage (2)
  • 5.4 Starting current (2)
  • 6 Calibration Conditions (2)
  • 6.1 Environmental Conditions (2)
  • 6.2 Measurement Standards and Other Equipment (3)
  • 7 Calibration Items and Calibration Methods (3)
  • 7.1 Appearance and Function Check (3)
  • 7.2 Clock Differential Calibration (3)
  • 7.3 Starting Voltage and Return Voltage Measurement (5)
  • 7.4 Starting Current Measurement (5)
  • 7.5 Calibration Uncertainty for Evaluation of Clock Differencing, Starting Voltage and Starting Current (5)
  • 8 Expression of Calibration Results (5)
  • 9 Re-school interval (6)
  • Appendix A Calibration Record Format (7)
  • Appendix B Calibration Certificate Inner Page Format (8)
  • Appendix C Calibration Uncertainty Evaluation Example (9)

1 Scope (1)

2 References (1)

3 Terms and units of measure (1)

3.1 Starting voltage (1)

3.2 Return voltage (1)

3.3 Starting current (1)

3.4 Reference Voltage (1)

4 Overview (1)

5 Metrological characteristics (2)

5.1 Clock Differencing (2)

5.2 Starting voltage (2)

5.3 Return voltage (2)

5.4 Starting current (2)

6 Calibration Conditions (2)

6.1 Environmental Conditions (2)

6.2 Measurement Standards and Other Equipment (3)

7 Calibration Items and Calibration Methods (3)

7.1 Appearance and Function Check (3)

7.2 Clock Differential Calibration (3)

7.3 Starting Voltage and Return Voltage Measurement (5)

7.4 Starting Current Measurement (5)

7.5 Calibration Uncertainty for Evaluation of Clock Differencing, Starting Voltage and Starting Current (5)

8 Expression of Calibration Results (5)

9 Re-school interval (6)

Appendix A Calibration Record Format (7)

Appendix B Calibration Certificate Inner Page Format (8)

Appendix C Calibration Uncertainty Evaluation Example (9)

Introduction

This specification is based on JJF 1071-2010 "Rules for the preparation of national measurement calibration specifications", JJF 1001-2011 Using Measurement Terms and Definitions" and JJF 1059.1-2012 Evaluation and Expression of Measurement Uncertainty.

This specification is the first release.

Voltage loss timer calibration specification

1 Scope

This specification applies to voltage-loss timers (pressure-loss timers, loss-of-voltage-off timers, loss-of-voltage-disconnected short-circuit timers Calibration).

2 references

JJF 1180 Time Frequency Measurement Terminology and Definition GB/T 17215.301-2007 Special requirements for multi-function electric energy meter DL/T 566-1995 Voltage Voltage Loss Timer Specifications for dated references, only dated editions apply to this specification; all undated references the latest version (including all amendments) applies to this specification.

3 Terms and units of measure

3.1 Starting voltage triggervoltage Let the timing unit act reliably and start counting the maximum input voltage in volts.

3.2 Return voltage the minimum value of the input voltage to change the timing unit from timed to stopped. Unit. V.

3.3 Starting current trigger current Under the condition that there is no voltage in the voltage loop, make the timing unit operate reliably and start the timing of the minimum input current Value in mA.

3.4 Reference voltage Determine the voltage value of the relevant characteristics of the meter, unit. V.

Classified according to different specifications, the reference voltage is generally divided into. 3 × 100V, 3 × 380V, 3 × 57.7/100V, 3×220/380V.

4 Overview

The voltage pressure loss timer (hereinafter referred to as the timer) is a dedicated device that displays and displays the voltage loop voltage loss time of the energy meter.

instrument. It is commonly used to monitor the operating status of three-phase three-wire (three-phase four-wire) active power (reactive power) meters. When running the power meter under the condition of the load current, voltage transformer loss, undervoltage and current transformer secondary circuit open when a road or man-made short circuit occurs, the timer can timely reflect the fault condition, give an alarm signal, and record the missing phase.

Pressure, breaking, short circuit time. According to the different functions, there are generally a pressure-loss timer, a pressure-loss timer, and a loss of voltage Short-circuit timers and other types. Take three-phase three-wire as an example, the internal working principle of the timer is shown in Figure 1, outside the timer the wiring is shown in Figure 2.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 12 pages — is available in the English PDF.

How to Download JJF 1658-2017

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
12 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

JJF 1658-2017

$235.00