JJF 1634-2017Calibration Specification for Linear Accelerometers at Ultra-low Frequency and Ultra-low Level Acceleration (English PDF)
This is a limited preview
Buy now to download the full PDF (12 pages)
Need quotation for your management?
Get a formal quotation for JJF 1634-2017 in 30 minutes.
Issued by
General Administration of Quality Supervision, Inspection and Quarantine
Level / Type
National · Mandatory
Issue date
September 26, 2017
Implementation date
December 26, 2017
Scope
JJF 1634-2017 (Calibration Specification for Linear Accelerometers at Ultra-low Frequency and Ultra-low Level Acceleration) is available as an English-translated PDF.
JJF 1634-2017 — This standard specifies the calibration items and calibration methods for line accelerometers (hereinafter referred to as accelerometers) under the conditions of ultra-low frequency (low limit to 0. 001 Hz) and micro-acceleration (lower limit to 5��10^-7 m/s^2).
Found what you need?
Document preview — JJF 1634-2017
National Standard of the People's Republic of China
- ICS
- 17.080
- Classification
- A 57
Issued by: General Administration of Quality Supervision, Inspection and Quarantine
Contents
- Introduction (II)
- 1 Scope (1)
- 2 References (1)
- 3 Terms and measurement units (1)
- 4 Overview (1)
- 4.1 Accelerometer working principle (1)
- 4.2 Accelerometer frequency response calibration principle (2)
- 5 Metrology (2)
- 5.1 Sensitivity Amplitude (2)
- 5.2 Sensitivity Frequency Response (2)
- 5.3 Sensitivity Linearity (3)
- 5.4 Dynamic Range (3)
- 5.5 Accelerometer dynamic threshold (3)
- 5.6 Accelerometer dynamic resolution (3)
- 6 Calibration conditions (3)
- 6.1 School accelerometer (3)
- 6.2 Calibration conditions (3)
- 6.3 Measurement standards and equipment (3)
- 6.4 Selection of calibration parameters (4)
- 6.5 Other requirements (4)
- 7 Calibration Items and Calibration Methods (4)
- 7.1 Reference Sensitivity Amplitude and Phase Shift Calibration (4)
- 7.2 Sensitivity Amplitude and Phase Frequency Response Calibration (5)
- 7.3 Sensitivity Amplitude Linearity Calibration (5)
- 7.4 Dynamic threshold calibration (5)
- 7.5 Dynamic Resolution Calibration (5)
- 8 Calibration Results (6)
- 9 Time interval of correction (6)
- Appendix A Accelerometer sensitivity calibration method and data processing (mathematical method) (7)
- Appendix B Evaluation examples of acceleration sensitivity measurement uncertainty (9)
- Appendix C Ultra-low frequency micro-acceleration calibration device works (12)
1 Scope (1)
2 References (1)
3 Terms and measurement units (1)
4 Overview (1)
4.1 Accelerometer working principle (1)
4.2 Accelerometer frequency response calibration principle (2)
5 Metrology (2)
5.1 Sensitivity Amplitude (2)
5.2 Sensitivity Frequency Response (2)
5.3 Sensitivity Linearity (3)
5.4 Dynamic Range (3)
5.5 Accelerometer dynamic threshold (3)
5.6 Accelerometer dynamic resolution (3)
6 Calibration conditions (3)
6.1 School accelerometer (3)
6.2 Calibration conditions (3)
6.3 Measurement standards and equipment (3)
6.4 Selection of calibration parameters (4)
6.5 Other requirements (4)
7 Calibration Items and Calibration Methods (4)
7.1 Reference Sensitivity Amplitude and Phase Shift Calibration (4)
7.2 Sensitivity Amplitude and Phase Frequency Response Calibration (5)
7.3 Sensitivity Amplitude Linearity Calibration (5)
7.4 Dynamic threshold calibration (5)
7.5 Dynamic Resolution Calibration (5)
8 Calibration Results (6)
9 Time interval of correction (6)
Appendix A accelerometer sensitivity calibration method and data processing (mathematical method) (7)
Appendix B Evaluation examples of acceleration sensitivity measurement uncertainty (9)
Appendix C ultra-low frequency micro-acceleration calibration device works (12)
Introduction
Linear accelerometers have a frequency response from low to direct current, the frequency range and acceleration amplitude range of existing national standards Wai can not cover the line frequency response bandwidth of the accelerometer. This specification, combined with the actual situation of linear accelerometer calibration, refers to the United States Institute of Electrical and Electronic Engineers in its organization established IEEEStd836-2009 "IEEE recommended line accelerometer Precision Centrifuge Test Specification "," Appendix E in the low-frequency range to determine the accelerometer transfer function "section prepared.
Ultra-low frequency micro-acceleration linear accelerometer calibration specification
1 Scope
This specification specifies the linear accelerometer (hereinafter referred to as the accelerometer) in the ultra-low frequency (lower limit to 0.001Hz), micro Acceleration (lower limit to 5 × 10-7m/s2) conditions of the calibration items and calibration methods.
2 reference documents this specification cites the following documents.
JJG233-2008 piezoelectric accelerometer Vibration, impact, speed measurement terms and definitions Inertial technical terms GJB1037A-2004 Single Shaft Servo Acceleration Accelerometer Test Method IEEE Recommended Linear Accelerometer Precision Centrifuge Test Specification for dated references, only the dated version applies to this specification; for undated references the latest version (including amendments) applies to this specification.
3 Terms and measurement units 3.1 ultra-low frequency the range is from quasi-static 0.001Hz to low frequency vibration 0.1Hz.
3.2 micro-acceleration ultra-lowLevelacceleration Acceleration in the range of 5 × 10 -7 m/s 2 to 1 × 10 -2 m/s 2.
3.3 Mathematical swing (virtual) simpleharmonicpendulum-vibrationgenerator Mathematical swing table refers to the use of arc-shaped guide rail in the vertical plane virtual large radius of curvature of the pendulum movement platform.
3.4 with tilt shaft speedtable ratetablewithtiltedaxisofrotation with a turntable capable of tilting the rotary table.
4 Overview
4.1 accelerometer working principle Accelerometer mainly by the equivalent test quality, conversion components and circuits and mounting base and other components. When the accelerometer goes along when the measured object is moving, the quality of detection is affected by the inertial force generated by the acceleration of the outside world. The conversion element generates a signal corresponding to the input plus Speed proportional to the output signal.
The mechanical model of a typical accelerometer approximates the typical second-order mechanical model of mass, spring, and damping system.
d2x
dt2 c
dt kx C = -ma
In the formula.
m --- equivalent test quality, kg;
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 12 pages — is available in the English PDF.
How to Download JJF 1634-2017
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
JJF 2425-2026 — Calibration specification for carbon dioxide incubators
JJF 1183-2025 — Calibration Specification for Temperature Transmitters
JJF 1282-2025 — Calibration Specification for Time Delay Relays
Secure payment via Stripe
Payments accepted
JJF 1634-2017
$325.00